• 제목/요약/키워드: Local density

검색결과 1,101건 처리시간 0.027초

저밀도 폴리에틸렌 일렉트렉트에 있어서 케리어의 성질과 Trap 깊이 해석에 대한 연구 (A study on the analysis of carrier properties and trap energy depth in the low-density polythylene electrets)

  • 이준웅
    • 전기의세계
    • /
    • 제29권8호
    • /
    • pp.511-518
    • /
    • 1980
  • The thermostimulated discharge currents of low-density polyethylene electrets were measured versus the principal experimental variables. Several electrode types were used for the charging and discharging procedures. The results led to know the experimental conditions for the heterocharge and homocharge accumulating and decreasing. The electronic structure parameters of polyethylene such as trap level, density of traps, hopping length, mobility, trap time constants were deduced. A method for evaluating the local electric field inside the electret is proposed.

  • PDF

온라인 지문 인식 시스템을 위한 지문 품질 측정 (Fingerprint Image Quality Assessment for On-line Fingerprint Recognition)

  • 이상훈
    • 대한전자공학회논문지SP
    • /
    • 제47권2호
    • /
    • pp.77-85
    • /
    • 2010
  • 온라인 지문 인식 시스템에서는 주변 환경, 사용자의 지문 상태 및 입력 방법에 따라 다양한 품질의 지문이 입력된다. 따라서 지문 인식 시스템의 성능을 향상시키기 위해서는, 입력된 지문 영상을 이용하여 본인과 타인간의 변별력을 높이는 연구뿐만 아니라 다양한 품질의 지문 영상들 중에서 품질이 좋은 지문 영상을 선택하여 이를 인식에 사용하는 연구도 병행이 되어야 한다. 하지만 대부분의 기존 연구에서는 지문의 지역적인 품질만을 측정하였기 때문에 한 장의 지문영상의 품질에 대한 예측은 거의 이루어지지 않았다. 따라서 본 논문에서는 획득된 지문 영상의 품질을 판단하기 위해서 지역적인 지문 품질 측정과 이를 통한 전역적 지문 품질 측정 방볍을 제안하였다. 지역적인 지문 품질 평가에서는 각 지문 블록에서 그레디언트(Gradient)의 확률 밀도 함수(Probability Density Function)의 형태를 측정하여 블록 별 품질 값을 예측하였고, 이를 기반으로 전역적인 품질 평가에서는 신경망(Neural network)올 사용하여 지문 영상 전체를 평가함으로써 입력된 영상의 사용 여부를 판단하였다. FVC2002 데이터베이스를 사용하여 실험한 결과, 제안한 전역적 방법을 사용하였을 때 NFIQ(NIST Fingerprint Image Quality)의 방법보다 정합 예측 성능이 높게 나타난 것올 확인할 수 있었다.

Study on mapping of dark matter clustering from real space to redshift space

  • Zheng, Yi;Song, Yong-Seon
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.38.2-38.2
    • /
    • 2016
  • The mapping of dark matter clustering from real to redshift spaces introduces the anisotropic property to the measured density power spectrum in redshift space, known as the Redshift Space Distortion (hereafter RSD) effect. The mapping formula is intrinsically non-linear, which is complicated by the higher order polynomials due to the indefinite cross correlations between the density and velocity fields, and the Finger-of-God (hereafter FoG) effect due to the randomness of the peculiar velocity field. Furthermore, the rigorous test of this mapping formula is contaminated by the unknown non-linearity of the density and velocity fields, including their auto- and cross-correlations, for calculating which our theoretical calculation breaks down beyond some scales. Whilst the full higher order polynomials remains unknown, the other systematics can be controlled consistently within the same order truncation in the expansion of the mapping formula, as shown in this paper. The systematic due to the unknown non-linear density and velocity fields is removed by separately measuring all terms in the expansion using simulations. The uncertainty caused by the velocity randomness is controlled by splitting the FoG term into two pieces, 1) the non-local FoG term being independent of the separation vector between two different points, and 2) the local FoG term appearing as an indefinite polynomials which is expanded in the same order as all other perturbative polynomials. Using 100 realizations of simulations, we find that the best fitted non-local FoG function is Gaussian, with only one scale-independent free parameter, and that our new mapping formulation accurately reproduces the observed power spectrum in redshift space at the smallest scales by far, up to k ~ 0.3 h/Mpc, considering the resolution of future experiments.

  • PDF

체적골밀도 측정법 동향: 수술부위 골밀도 분석 (Volumetric Bone Mineral Density Measurement: for Surgery Specific Bone Volumes)

  • 이연수
    • 한국방사선학회논문지
    • /
    • 제16권1호
    • /
    • pp.53-59
    • /
    • 2022
  • CT영상을 기반으로 한 QCT는 CT장비와 컴퓨터영상처리기술의 발전과 함께 적은 방사선 투과양으로도 체적골밀도를 측정할 수 있는 방향으로 크게 발전하고 있다. 방사선 의료영상을 대표적인 골밀도 측정법인 이중방사선흡수계수법(DXA)은 척추나 근위대퇴골과 다른 뼈와의 상관성이 떨어지는 경우가 많고질량효과에 의한 부정확성의 근본 원인을 가지고 있기 때문에 체적골밀도측정법인 단일에너지CT영상을 이용한 QCT법이 가장 보편적인 정확한 골밀도 측정법이다. 이중에너지CT의 사용은 단단한 뼈와 동시에 종양이나 연부조직의 이상을 같이 볼 수 있는 영상을 얻을 수 있게 되어 QCT 골밀도와 함께 특정연부조직이나 장기를 검사할 수 있어 그 사용이 더욱 늘어날 것으로 예상된다. 임상수술이나 추적검사가 필요한 위치에 사용자가 해부학적으로 특정한 형상체적에 대한 국부골밀도측정 방법도 병원의 임상현장에서 활용할 기술로 대두되고 있다.

자기장 내의 위상최적화 방법에 대한 연구 - 밀도법과 균질화법의 비교 - (A Study on the Topology Optimization in Magnetic Fields - Comparisons Between the Density Method and the Homogenization Design Method)

  • 유정훈
    • 대한기계학회논문집A
    • /
    • 제28권4호
    • /
    • pp.370-377
    • /
    • 2004
  • The density approach and the homogenization design method are representative methods in topology optimization problems. In the topology optimization in magnetic fields, those methods are applied based on the results of the applications In elastic fields. In this study, the density method is modified considering the concept of the homogenization design method. Also, the results of the topology optimization in magnetic fields by the modified density method as well as the homogenization method are compared especially focusing the change of the penalization parameter in the density approach. The effect of the definition of the design domain such as global/local design domain is also discussed.

HOT GAS HALOS IN EARLY-TYPE GALAXIES AND ENVIRONMENTS

  • Kim, Eunbin;Choi, Yun-Young;Kim, Sungsoo S.
    • 천문학회지
    • /
    • 제46권1호
    • /
    • pp.33-40
    • /
    • 2013
  • We investigate the dependence of the extended X-ray emission from the halos of optically luminous early-type galaxies on the small-scale (the nearest neighbor distance) and large-scale (the average density inside the 20 nearest galaxies) environments. We cross-match the 3rd Data Release of the Second XMMNewton Serendipitous Source Catalog (2XMMi-DR3) to a volume-limited sample of the Sloan Digital Sky Survey (SDSS) Data Release 7 with $M_r$ < -19.5 and 0.020 < z < 0.085, and find 20 early-type galaxies that have extended X-ray detections. The X-ray luminosity of the galaxies is found to have a tighter correlation with the optical and near infrared luminosities when the galaxy is situated in the low large-scale density region than in the high large-scale density region. Furthermore, the X-ray to optical (r-band) luminosity ratio, $L_X/L_r$, shows a clear correlation with the distance to the nearest neighbor and with large-scale density environment only where the galaxies in pair interact hydrodynamically with seperations of $r_p$ < $r_{vir}$. These findings indicate that the galaxies in the high local density region have other mechanisms that are responsible for their halo X-ray luminosities than the current presence of a close encounter, or alternatively, in the high local density region the cooling time of the heated gas halo is longer than the typical time between the subsequent encounters.

Zinc Blende 구조를 가지는 ZnSe 결정의 밴드 특성에 관한 연구 (A Study on the Band Characteristics of ZnSe Thin Film with Zinc-blende Structure)

  • 박정민;김환동;윤도영
    • 전기화학회지
    • /
    • 제14권3호
    • /
    • pp.145-151
    • /
    • 2011
  • ZnSe는 가시광선 영역에서 넓은 밴드갭을 가지고 있는 II-VI족 화합물 반도체 소자로서 레이저 다이오드, 디스플레이 그리고 태양전지와 같은 다양한 응용분야에 적용되고 있다. 본 연구에서는 전기화학적 전착방법을 이용하여 ITO 전극상에 ZnSe 박막을 합성하여, XRD와 SEM으로 ZnSe 결정의 합성과 zinc blende 구조의 형태를 관측하였고, UV 분광기를 활용하여 밴드갭을 측정한 결과 2.76 eV이었다. 또한, 분자동역학에서 활용되는 밀도범함수 이론 (DFT, Density Functional Theory)을 도입하여 ZnSe 결정에 대한 밴드 구조의 해석을 수행하였다. Zinc blende구조를 갖는 ZnSe 결정에 대하여 LDA (Local Density Approximation), PBE (Perdew Burke Ernzerhof), 그리고 B3LYP (Becke, 3-parameter, Lee-Yang-Parr) 범함수를 이용하여 밴드구조와 상태밀도 (Density of State)를 모사하였다. 각각의 경우에 대해 에너지 밴드갭을 구한 결과, B3LYP 범함수로 해석한 경우에 실험치와 근사치인 2.65 eV의 밴드갭을 보여주었다.

구강편평세포암종의 미세혈관 밀도와 악성도간 상관관계에 관한 임상병리학적 연구 (THE CLINICOPATHOLOGICAL STUDY ON THE RELATION OF MICROVESSEL DENSITY AND AGGRESSIVENESS IN ORAL SQUAMOUS CELL CARCINOMA)

  • 이기철;명훈;임성삼;김명진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권2호
    • /
    • pp.155-160
    • /
    • 2002
  • Oral squamous cell carcinoma (OSCC), the most common head and neck cancer, shows poor prognosis as a result of frequent local invasion and lymph node metastasis that is mediated by multiple proteolytic enzymes and angiogenesis. In recent reports, angiogenesis is known to play an important role in tumor invasion and metastasis. The purpose of this study was to determine the role of angiogenesis in OSCCs, particularly with respect to the invasive and the metastatic potential. The microvessel density (CD31) in 34 human OSCC cases were investigated by immunohistochemistry, and reviewed with respect to the invasiveness and the presence of lymph node metastasis and following results were obtained. The blood vessel density $(28.8{\pm}7.9)$ in the strong invasive cases were significantly higher than those $(23.3{\pm}6.9)$ in the weak invasive cases. (p<0.05) In the 14 cases with lymph node metastasis, the average blood vessel density was $28.5{\pm}9.6$. On the other hand, in the 20 cases without lymph node metastasis, the blood vessel density was $25.2{\pm}6.4$. The blood vessel density was not statistically related to lymph node metastasis. (p>0.05) These results suggest that angiogenesis may be related to the local invasion of OSCC and further research will be needed to investigate the possibility that antiangiogenic agent can be used as an anticancer agent for OSCC.

Pattern of buccal and palatal bone density in the maxillary premolar region: an anatomical basis of anterior-middle superior alveolar (AMSA) anesthetic technique

  • Ahad, Abdul;Haque, Ekramul;Naaz, Sabiha;Bey, Afshan;Rahman, Sajjad Abdur
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권6호
    • /
    • pp.387-395
    • /
    • 2020
  • Background: The anterior-middle superior alveolar (AMSA) anesthetic technique has been reported to be a less traumatic alternative to several conventional nerve blocks and local infiltration for anesthesia of the maxillary teeth, their periodontium, and the palate. However, its anatomic basis remains controversial. The present study aimed to determine if the pattern of cortical and cancellous bone density in the maxillary premolar region can provide a rationale for the success of the AMSA anesthetic technique. Method: Cone-beam computed tomography scans of 66 maxillary quadrants from 34 patients (16 men and 18 women) were evaluated using a volumetric imaging software for cortical and cancellous bone densities in three interdental regions between the canine and first molar. Bone density was measured in Hounsfield units (HU) separately for the buccal cortical, palatal cortical, buccal cancellous, and palatal cancellous bones. Mean HU values were compared using the Mann-Whitney U test and one-way ANOVA with post-hoc analysis. Results: Cancellous bone density was significantly lower (P ≤ 0.001) in the palatal half than in the buccal half across all three interdental regions. However, there was no significant difference (P = 0.106) between the buccal and palatal cortical bone densities at the site of AMSA injection. No significant difference was observed between the two genders for any of the evaluated parameters. Conclusions: The palatal half of the cancellous bone had a significantly lower density than the buccal half, which could be a reason for the effective diffusion of the anesthetic solution following a palatal injection during the AMSA anesthetic technique.