• Title/Summary/Keyword: Local Minimum

Search Result 827, Processing Time 0.033 seconds

A LOCAL-GLOBAL STEPSIZE CONTROL FOR MULTISTEP METHODS APPLIED TO SEMI-EXPLICIT INDEX 1 DIFFERENTIAL-ALGEBRAIC EUATIONS

  • Kulikov, G.Yu;Shindin, S.K.
    • Journal of applied mathematics & informatics
    • /
    • v.6 no.3
    • /
    • pp.697-726
    • /
    • 1999
  • In this paper we develop a now procedure to control stepsize for linear multistep methods applied to semi-explicit index 1 differential-algebraic equations. in contrast to the standard approach the error control mechanism presented here is based on monitoring and contolling both the local and global errors of multistep formulas. As a result such methods with the local-global stepsize control solve differential-algebraic equation with any prescribed accuracy (up to round-off errors). For implicit multistep methods we give the minimum number of both full and modified Newton iterations allowing the iterative approxima-tions to be correctly used in the procedure of the local-global stepsize control. We also discuss validity of simple iterations for high accuracy solving differential-algebraic equations. Numerical tests support the the-oretical results of the paper.

The Public-Private Partnerships and the Fiscal Soundness of Local Governments in Korea

  • LEE, HOJUN
    • KDI Journal of Economic Policy
    • /
    • v.39 no.1
    • /
    • pp.41-82
    • /
    • 2017
  • This paper studies the risks associated with local finance in Korea by identifying the financial status of each local government, including the financial burdens of PPP projects, and examined governmental future burdens related to PPP projects. We reviewed all fiscal burdens associated with projects, such as, for BTL (Build-Transfer-Lease) types of projects, facility lease and operating expenses, and, for the BTO (Build-Transfer-Operate) types of projects, construction subsidies that are paid at the construction stage, MRG (Minimum Revenue Guarantee) payments and the government's share of payment. Furthermore, we compared the annual expenditures of local governments on PPP projects against their annual budgets and checked if the 2% ceiling rule could be applied.

VARIATION OF LOCAL POOL BOILING HEAT TRANSFER COEFFICIENT ON 3-DEGREE INCLINED TUBE SURFACE

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.911-920
    • /
    • 2013
  • Experimental studies on both subcooled and saturated pool boiling of water were performed to obtain local heat transfer coefficients on a $3^{\circ}$ inclined tube of 50.8 mm diameter at atmospheric pressure. The local values were determined at every $45^{\circ}$ from the very bottom to the uppermost of the tube periphery. The maximum and minimum local coefficients were observed at the azimuthal angles of $0^{\circ}$ and $180^{\circ}$, respectively, in saturated water. The locations of the maxima and the minima were dependent on the inclination angle of the tube as well as the degree of subcooling. The major heat transfer mechanisms were considered to be liquid agitation generated by the sliding bubbles and the creation of big size bubbles through bubble coalescence. As a way of quantifying the heat transfer coefficients, an empirical correlation was suggested.

Prediction of Heave Natural Frequency for Floating Bodies (부유체의 상하동요 고유진동수 예측)

  • Kim, Ki-Bum;Lee, Seung-Joon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.4
    • /
    • pp.329-334
    • /
    • 2017
  • As the motion response of heave for floating bodies on the water surface is relatively large near the natural frequency, it is necessary to predict its value accurately from the stage of initial design. Bodies accelerating in fluid experience force acted upon by the fluid, and this force is quantified by using the concept of added mass. For predicting the natural frequency of heave we need to know the added mass, which is given as a function of frequency, and hence the natural frequency can be obtained through only by iteration process, as was pointed out by Lee (2008). His method was applied to circular cylinders, and two dimensional cylinders of Lewis form by making use of the Ursell-Tasai method in the previous works, Lee and Lee (2013), Kim and Lee (2013), and Song and Lee (2015). In this work, a similar algorithm employing the concept of strip method is adopted for predicting the heave natural frequency of KCS(KRISO Container Ship), and the obtained computational result was compared with other existing experimental data, and the agreement seems reasonable. Furthermore, through the error analysis, it is shown that why the frequency corresponding to the local minimum of the added mass and the natural frequency are very close. And it seems probable that we can predict the heave natural frequency if we know only the local minimum of added mass and the corresponding frequency under a condition, which holds for ship-like bodies in general.

Characteristics of Sea Breezes at Coastal Area in Boseong (보성 해안 지역에서의 해풍 특성)

  • Lim, Hee-Jeong;Lee, Young-Hee
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.41-51
    • /
    • 2019
  • The characteristics of the sea breeze were investigated using the wind and temperature data collected from 300-m tower at Boseong from May 2014 to April 2018. Sea breeze day was detected using following criteria: 1) the presence of a clear change in wind direction near sunrise (between 1 hour after sunrise and 5 hours before sunset) and sunset (from 1500 LST to midnight), 2) presence of thermal forcing of sea breeze and 3) no heavy precipitation (rain < $10mm\;d^{-1}$). Sea breeze days occurred on 569 days for 4 years. The monthly distribution of sea breeze day occurrence shows maxima in May and September and minimum in December. The average onset and cessation times of the sea breeze are 0942 LST and 1802 LST, respectively. Although the 10-m wind shows clockwise rotation with time in the afternoon, the observed hodograph does not show an ideal elliptical shape and has different characteristics depending on the upper synoptic wind direction. Vertical structure of sea breeze shows local maximum of wind speed and local minimum of virtual potential temperature at 40 m in the afternoon for most synoptic conditions except for southeasterly synoptic wind ($60^{\circ}{\sim}150^{\circ}$) which is in the same direction as onshore flow. The local minimum of temperature is due to cold advection by sea breeze. During daytime, the intensity of inversion layer above 40 m is strongest in westerly synoptic wind ($240^{\circ}{\sim}330^{\circ}$) which is in the opposite direction to onshore flow.

Spatial Distribution of Urban Heat Island based on Local Climate Zone of Automatic Weather Station in Seoul Metropolitan Area (자동기상관측소의 국지기후대에 근거한 서울 도시 열섬의 공간 분포)

  • Hong, Je-Woo;Hong, Jinkyu;Lee, Seong-Eun;Lee, Jaewon
    • Atmosphere
    • /
    • v.23 no.4
    • /
    • pp.413-424
    • /
    • 2013
  • Urban Heat Island (UHI) intensity is one of vital parameters in studying urban boundary layer meteorology as well as urban planning. Because the UHI intensity is defined as air temperature difference between urban and rural sites, an objective sites selection criterion is necessary for proper quantification of the spatial variations of the UHI intensity. This study quantified the UHI intensity and its spatial pattern, and then analyzed their connections with urban structure and metabolism in Seoul metropolitan area where many kinds of land use and land cover types coexist. In this study, screen-level temperature data in non-precipitation day conditions observed from 29 automatic weather stations (AWS) in Seoul were analyzed to delineate the characteristics of UHI. For quality control of the data, gap test, limit test, and step test based on guideline of World Meteorological Organization were conducted. After classifying all stations by their own local climatological properties, UHI intensity and diurnal temperature range (DTR) are calculated, and then their seasonal patterns are discussed. Maximum UHI intensity was $4.3^{\circ}C$ in autumn and minimum was $3.6^{\circ}C$ in spring. Maximum DTR appeared in autumn as $3.8^{\circ}C$, but minimum was $2.3^{\circ}C$ in summer. UHI intensity and DTR showed large variations with different local climate zones. Despite limited information on accuracy and exposure errors of the automatic weather stations, the observed data from AWS network represented theoretical UHI intensities with difference local climate zone in Seoul.

Analysis and Evaluation of Life SOC in Boeun-gun According to Minimum Criterion of Basic Life Infrastructures (기초생활인프라 최저기준에 따른 보은군의 생활인프라 시설 충족도 분석 및 유형화)

  • Yang, Seunghwan;Lee, Byungjun;Yoon, Seongsoo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.3
    • /
    • pp.15-27
    • /
    • 2020
  • Living infrastructure facilities are concentrated in cities with high population density, it is necessary to supply basic living infrastructure facilities to promote welfare in rural areas. The establishment of basic living infrastructure is the minimum right for daily living of local residents. It is supplied by considering national economic and social characteristics through national minimum standards, but it is limited to be practically applied to rural areas where many villages are dispersed in large areas. There is a situation. Therefore, it is necessary to supply systematic and quantitative facilities by analyzing villages that do not meet the minimum standards of basic living infrastructure in rural areas and by considering their characteristics. The purpose of this study is to identify the basic living infrastructure facilities of village units and analyze the characteristics of each village for Boeun-gun, Chungcheongbuk-do.

LOS-based Local Path Planning for Self organization of Unicycle Swarm Robots (유니사이클 스웜 로봇의 자기조직화를 위한 LOS 기반의 국소 경로 계획)

  • Jung, Hah-Min;Kim, Dong-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1881_1882
    • /
    • 2009
  • Simple quadratic potential functions for unicycle robot path planning are presented, where proposed algorithm for path planning has the different environment for each robot based on LOS(Line Of Sight) between a target and an obstacle, unlike a conventional path planning. In doing so, the proposed algorithm assumes that each swarm robot equips its own vision instead of a ceiling camera. In particular, this paper presents that each robot follows its different local leader. As a result proposed algorithm reduces local minimum problems by the help of each local leader.

  • PDF

Development of Standard Procedures for Local Leakage Rate Testing of Containment Vessel (격납건물 국부누설률시험 표준절차 개발)

  • Moon, Yong-Sig;Kim, Chang-Soo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.42-47
    • /
    • 2012
  • The containment local leakage rate testing in nuclear power plants is performed in accordance with ANSI/ANS 56.8-1994 in Korea. Two methods, the make-up flow rate and the pressure decay, are used for local leakage rate testing. Though ANSI/ANS 56.8-1994 does not define clearly the minimum test duration for the make-up flow rate method, it requires obtaining the data after reaching the stable condition. Thus the prerequisite stable condition for data acquisition and the testing time is differently applied to each NPPs. Therefore, this study presents a standardized test procedure for data stabilization and testing time through experiments to improve the test reliability.

A Study on Voltage and Reactive Power Control Methodology using Integer Programming and Local Subsystem (지역 계통 구성과 Integer programming을 이용한 전압 및 무효전력 제어방안 연구)

  • Kim, Tae-Kyun;Choi, Yun-Hyuk;Seo, Sang-Soo;Lee, Byong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.543-550
    • /
    • 2008
  • This paper proposes an voltage and reactive power control methodology, which is motivated towards implementation in the korea power system. The main voltage control devices are capacitor banks, reactor banks and LTC transformers. Effects of control devices are evaluated by local subsystem's cost computations. This local subsystem is decided by 'Tier' and 'Electrical distance' in the whole system. The control objective at present is to keep the voltage profile within constraints with minimum switching cost. A robust control strategy is proposed to make the control feasible and optimal for a set of power-flow cases that may occur important event from system. This studies conducted for IEEE 39-bus low and high voltage contingency cases indicate that the proposed control methodology is much more effective than PSS/E simulation tool in deciding switching of capacitor and reactor banks.