• Title/Summary/Keyword: Loading margin

Search Result 98, Processing Time 0.028 seconds

A STUDY ON THE STRESS DISTRIBUTION OF POSTERIOR FIXED PARTIAL DENTURE WITH VARIOUS ALL-CERAMIC SYSTEMS (구치부 고정성 국소의치에서 전부도재 시스템에 따른 응력분포에 관한 연구)

  • Kang Han-Joong;Dong Jin-Keun;Oh Sang-Chun;Lee Hae-Hyoung;Song Ki-Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.204-217
    • /
    • 2005
  • Purpose. The purpose of this study was to analyze stress distribution of all ceramic posterior fixed partial denture using a three dimensional finite element method. Material and method. A three dimensional finite element model was created to demonstrate all-ceramic posterior fixed partial denture and then this computer model measured the stress distribution of the all ceramic bridges which has a ceramic core materials such as Zirconia, IPS Empress. 2. In-Ceram zirconia, Metal-Ceramic. Also the stress distribution was examined according to loading sites when force was applied to sites such as the central area of second premolar the mesial connector of pontic, the central fossa of pontic, the distal connector of pontic, and the central fossa of second molar. Results. 1. In all the materials of the core in this study, von Mises stress indicated that the stress increased as force was applied to loaded sites, just at those points, on the connector, and the margin in the area adjacent to the connectors. 2. The maximum principal stress was much higher in the lower part of the connectors than in any other region. 3. As the load was applied to the different locations, the research showed a consistent increase of stress in the lower connectors. The maximum value of the von Mises stress was two or three times greater when the load was applied directly to the connectors rather than indirectly through another stressed region. 4. In the case of In-Ceram zirconia, the stress in lower connectors was the highest of all the reference points, the stress showed 75% of all the maximum stress. Ziconia showed 72%, Metal Ceramic 67% and IPS Empress 2 50%. 5. In the case of Ziconia, the stress was well dispersed in each reference point that the stress differences were smaller when compared to In-Cream ziconia.

Analysis of Failure Behavior of Piles Embedded in Liquefied Soil Deposits (액상화 지반에 근입된 말뚝의 파괴거동 분석)

  • Cho, Chong-Suck;Han, Jin-Tae;Hwang, Jae-Ik;Park, Young-Ho;Kim, Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.11
    • /
    • pp.123-131
    • /
    • 2006
  • Liquefaction-induced lateral spreading has been the most extensive damage to pile foundations during earthquakes. Several cases of pile failures were reported despite the fact that a large margin of safety factor was employed in their design. In this study, 1-g shaking table tests were performed in order to analyze the failure behavior of piles embedded in liquefied soil deposits by buckling instability. As a result, it can be concluded that the pile subjected to excessive axial loads $(near\;P_{cr})$ can fail easily by buckling instability during liquefaction. When lateral spreading took place in sloping grounds, it was found that lateral loading due to lateral spreading increased lateral deflection of pile and reduced the buckling load. In addition, from the buckling shape of pile, difference between Euler's buckling and pile buckling vat observed. In the case of pile buckling, hinge formed at the middle point of the pile, not at the bottom. And in sloping grounds, location of hinge formation got lower compared with level ground because of the soil movements.

Seismic Performance Evaluation on Bending Deformation of 2-Ply and 3-Ply Bellows Expansion Pipe Joints (2겹 및 3겹 벨로우즈 신축배관이음의 휨 변형에 대한 내진성능평가 )

  • Sung-Wan Kim;Sung-Jin Chang;Dong-Uk Park;Bub-Gyu Jeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.33-41
    • /
    • 2023
  • The application of seismic separation joints that can improve the deformation capacity of piping is an effective way to improve seismic performance. Seismic separation joints capable of axial expansion and bending deformation are installed where deformation is expected and used for the purpose of safely protecting the piping. Bellows are flexible and have low stiffness, so they can be used as seismic separation joints because they have excellent ability to respond to relatively large deformation. In this study, the seismic performance and limit state for bending deformation of 2-ply and 3-ply bellows specimens were evaluated. Seismic performance was evaluated by applying an increasing cyclic load to consider low-cycle fatigue due to seismic load. In order to confirm the margin for the limit state of the evaluated seismic performance, an experiment was conducted in which a cyclic loading of constant amplitude was applied. As a result of the experiment, it was confirmed that the bellows specimen was made of stainless steel and had a high elongation, so that the 2-ply bellows specimen had the limit performance of resisting within 3 cycles even at the maximum forced displacement of the 3-ply bellows specimen.

Exposure and Risk Assessment for Operator Exposure to Insecticide Acetamiprid during Water Melon Cultivation in Greenhouse using Whole Body Dosimetry (수박 시설재배에서 살충제 Acetamiprid 사용 시 전신노출법에 의한 농작업자의 노출 및 위해성평가)

  • Kim, Eunhye;Lee, Jiho;Sung, Jeonghee;Lee, Jonghwa;Shin, Yongho;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.247-257
    • /
    • 2014
  • Assessment for operator's dermal and inhalation exposure to acetamiprid during cultivation of water melon in greenhouse was carried out. For dermal exposure measurement, whole body dosimetry (WBD) was performed as the first trial in Korea. WBD consists of cotton/polyester outer clothes and cotton inner clothes. Hand exposure was measured by washing of nitrile gloves and hands while head exposure was monitored by face/neck wipe technique. Inhalation exposure was monitored with personal air sampling pumps and IOM sampler (glass fiber filter). Analytical limit of quantitation was 2.5 ng/mL. Good reproducibility (C.V < 8.7%), linearity ($R^2$ > 0.99) and recovery (70~119%) were obtained. Field recovery of acetamiprid was 77~95%. During mixing/loading, hand exposure of acetamiprid was about 10 times ($229.7{\mu}g$) more than that of application case ($20.9{\mu}g$). During application, total dermal exposure was $1207.4{\mu}g$. Exposure of lower legs was $1132.1{\mu}g$, which is 93.8% of the total dermal exposure. Inhalation exposure during mixing/loading and application was not detected. Margin of safety (MOS) was calculated for risk assessment using male Korean average body weight (70 kg) and acceptable operator exposure level ($124{\mu}g/kg/day$) to give 140, suggesting that health risk of operator during treatment of acetamiprid for water melon in greenhouse could be safe.

Exposure Assessment of Apple Orchard Workers to the Insecticide Imidacloprid Using Whole Body Dosimetry During Mixing/Loading and Application (전신복장법을 이용한 농약 조제 및 살포 과정 중 살충제 Imidacloprid에 대한 사과 과수원 농작업자의 노출 평가)

  • Lee, Jae Yun;Noh, Hyun Ho;Park, Hyo Kyoung;Jeong, Hye Rim;Jin, Me Jee;Park, Kyung-Hun;Kim, Jeong-Han;Kyung, Kee Sung
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.3
    • /
    • pp.271-279
    • /
    • 2016
  • To evaluate exposure characteristics of the insecticide imidacloprid to apple orchard workers during treatment on orchard fields and evaluate its potential risk using a whole body dosimetry (WBD) method, 1,000-time diluted acephate+imidacloprid 25(20+5)% solutions were sprayed on 10 apple orchard fields in Cheongju with a speed sprayer at a rate of 3,000 L/ha/person, after put on clothes such as inner/outer clothes, personal air pump with a IOM sampler, nitrile glove and mask. Exposure test included mixing, loading and application steps. The test pesticide imidacloprid residues in the collected samples were analyzed with a HPLC-DAD. Recoveries ranged from 81.5 to 108.6% for analytical method validation and from 73.8 to 86.7% for field recovery. Total exposed amounts to mixer/loader and applicator were found to be 0.0014-0.0279% of total applied active ingredient of imidacloprid. Glove exposure of both mixer/loader and applicator was higher than the other parts. Margins of safety of mixer/loader and applicator were calculated to be 97-355 and 46-196, respectively, indicating that exposure risk of imidacloprid to apple orchard workers by spraying with a speed sprayer was very low.

The Effect of Surface Sealing on the Microleakage of Class V Composite Resin Restorations (제V급 복합레진 수복물의 표면전색이 미세변연누출에 미치는 효과)

  • Youn, Yeon-Hee;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.359-369
    • /
    • 2007
  • This in vitro study was performed to assess the effect of surface sealing on the microleakage of class V composite resin restorations that underwent several aging treatments. Class V cavities were prepared on the buccal surface of 100 sound extracted premolars and restored with a hybrid light-cured composite resin according to the manufacturer's instructions. They were randomly divided into two groups consisting of 50 samples: group I, without surface sealing, and group II, in which margins were etched and surface sealant was applied. After thermocycling, each group was divided into five subgroups, respectively, to represent the five aging treatments: group A = no further treatment (only thermocycling), B = toothbrushing, C = load cycling, D = toothbrushing followed by load cycling, and E = aging treatment in deionized water for six months. Microleakage was assessed by examining the penetration of 2% methylene blue dye. The following results were obtained: 1. At occlusal and cervical margins in groups without surface sealing, there was no significant difference in microleakage after the several aging treatments (p>0.05). 2. The occlusal margins of groups with surface sealing showed no significant differences after the several aging treatments (p>0.05). 3. In the cervical margins of groups with surface sealing, microleakage significantly increased after load cycling or aging in deionized water for six months (p<0.05). 4. The no-further-treatment group and the toothbrushing group with surface sealing showed less microleakage than the corresponding groups without surface sealing (p<0.05). 5. The surface-sealed groups with load cycling or aging in deionized water showed no significant difference in microleakage to the corresponding groups without surface sealing (p>0.05). In conclusion, the results of this study suggest that the surface sealant infiltrating through the gap of the cervical margin exerted a positive effect on microleakage at the initial stage, but the effect was not sufficient to overcome the stress generated by the cuspal flexure during occlusal loading and water absorption.

  • PDF

Laterally Unbraced Length for Preventing Inelastic Lateral-Torsional Buckling of High-Strength Steel Beams (고강도 강재보의 비탄성 횡-비틀림좌굴 제어를 위한 횡지지 거리)

  • Park, Chang Hee;Lee, Cheol Ho;Han, Kyu Hong;Kim, Jin Ho;Lee, Seung Eun;Ha, Tae Hyu;Kim, Jin Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.2
    • /
    • pp.115-130
    • /
    • 2013
  • In this study, lateral-torsional buckling (LTB) strength of high-strength H-beams built up from 800MPa tensile-strength steel was experimentally and analytically evaluated according to current lateral stability provisions (KBC 2009, AISC-LRFD 2010). The motivation was to evaluate whether or not current LTB provisions, which were originally developed for ordinary steel with different stress-strain characteristics, are still applicable to high-strength steel. Two sets of compact-section specimens with relatively low (Set A) or high (Set B) warping stiffness were prepared and tested under uniform moment loading. Laterally unbraced lengths of the test specimens were controlled such that inelastic LTB could be induced. All specimens exhibited LTB strength exceeding the minimum limit required by current provisions by a sufficient margin. Moreover, some specimen in Set A reached a rotation capacity required for plastic design, although its laterally unbraced length belonged to the inelastic LTB range. All the test results indicated that extrapolation of current provisions to high-strength steel is conservative. In order to further analyze the test results, the relationship between inelastic moment and laterally unbraced length was also derived in explicit form for both ordinary- and high-strength steel based on the effective tangent modulus of inelastic section. The analytical relationship derived again showed that extrapolation of current laterally unbraced length limit leads to a conservative design in the case of high-strength steel and that the laterally unbraced length to control the inelastic LTB behavior of high-strength steel beam should be specified by including its unique post-yield strain-hardening characteristics.

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.