• Title/Summary/Keyword: Loading System

Search Result 3,328, Processing Time 0.037 seconds

Prediction of Water Quality improvement for Estuarine Reservoir using Wetland-Detention Pond System (습지-저류지에 의한 하구 담수호 수질개선 효과 예측)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.5
    • /
    • pp.94-102
    • /
    • 2000
  • Investigated was the effectiveness of a constructed wetland system on water quality in Hwa-Ong estruarin reservoir, located in Hwasung-Gun, Kyunggi-Do. Procedures for estimation of pollutant loading from watershed and required area for natural systems, and simulation of corresponding reservoir water quality were reviewed. Generally, simulated reservoir water quality was within the reasonable range, and about 15% of total polder farmland was required to meet the agricultural water quality standards. The model was applied based on the current loading condition without additional treatment systems. Wetland system is an ecologically sound treatment system. Therefore, natural systems can be an alternative measure for water quality improvement in polder projects. The area for natural systems was estimated using literature value which might be acceptable at the planning stage. However, pilot system and its experimental data are requisite for large scale field application. WASP5 was proved to be a useful and versatile model, and its application to estuarine reservoir water quality simulation was thought to be appropriate.

  • PDF

Performance of Microbial Fuel Cell Integrated with Anaerobic Membrane Filter for Continuous Sewage Treatment with Stable Effluent Quality (안정적 유출수질의 연속 하수처리를 위한 혐기성 멤브레인 필터와 통합된 미생물연료전지의 성능 평가)

  • Lee, Yunhee;Oa, Seong-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.808-812
    • /
    • 2013
  • A new type of microbial fuel cell (MFC) with anaerobic membrane filter was designed to produce bioelectricity and to treat domestic sewage at relatively high organic loading rate (OLR) of $6.25kgCOD/m^3/day$ and short hydraulic retention time (HRT) of 1.9 h. A following aeration system was applied to ensure effluent water quality in continuous operation. Glucose was supplemented to increase the influent concentration of domestic sewage. Influent substrate of 95% was removed via the MFC and following aeration system and the corresponding maximum power density was $25.6mW/m^3$. External resistor of $200{\Omega}$ and air-cathode system contributed better MFC performance comparing to $2000{\Omega}$ and dissolved oxygen as a catholyte.

On the Untact ICT based New Concept Storage Device Design by Interworking SysML and CAD Data to Improve the Development Efficiency

  • Kim, Myung Sung;Park, Jae Min;Kim, Young Min
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.258-269
    • /
    • 2022
  • In these days, innovative functions are required to unmanned parcel delivery lockers. As non-face-to-face transactions become the center due to the recent COVID-19 pandemic, many problem occurs in society such as theft crimes and lack of loading space. Therefore, New concept storage device is developed in korea. It has the functions that minimizes empty spaces by using the internal transport device to enable efficient space loading and refrigerate goods such as foods. In order to systematically approach the system design of the unmanned parcel delivery lockers which is the new function is applied, We applied model-based system engineering to improve the development efficiency and use a system modeling language to express the system. We conducted interworking research of CAD data including system modeling and design data. it is expected that this method will increase the effective development efficiency such as maintenance traceability and reduction of development period and cost.

Development of Automatic Optical Fiber Alignment System and Optimal Aligning Algorithm (자동 광 정렬시스템 및 최적 광 정렬알고리즘의 개발)

  • Um, Chul;Kim, Byung-Hee;Choi, Young-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.4
    • /
    • pp.194-201
    • /
    • 2004
  • Optical fibers are indispensable fer optical communication systems that transmit large volumes of data at high speed. But the aligning technology under the sub-micron accuracy is required for the precise axis adjustment and connection. For the purpose of precise alignment of the optical arrays, in this research, we have developed the 12-axis(with 8 automated axis and 4 manual axis) automatic optical fiber alignment system including the image processing-based searching system, the automatic loading system using the robot and the suction toot and the automatic UV bonding system. In order to obtain the sub-micron alignment accuracy, two 4-axis PC-based motion controllers and the two 50nm resolution 6-aixs micro-stage actuated by micro stepping motors are adopted. The fiber aligning procedure consists of two steps. Firstly, the optical wave guide and an input optical array are aligned by the 6-axis input micro-stage with the IR camera. The image processing technique is introduced to reduce primary manual aligning time and result in achieving the 50% decrease of aligning time. Secondly, the IR camera is replaced by the output micro-stage and a wave guide and two optical arrays are aligned simultaneously before the laser power intensity delivered to the optical powermeter reached the threshold value. When the aligning procedure is finished, the wave guide and arrays are W bonded. The automatic loading/unloading system is also introduced and the entire wave guide handing time is reduced significantly compared to the former commercial aligning system.

Development of a Rough Rice Handling Equipment for In-Bin Drying and Storage System (개량 곳간용 벼이송장치(移送裝置) 개발(開發))

  • Chang, D.I.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.3
    • /
    • pp.44-51
    • /
    • 1988
  • The objective of this study is to develop a grain handling system for loading, unloading and transporting of rough rice stored at the in-bin drying and storage (IBDS) developed by the Korea Advanced Institute of Science and Technology(KAIST). A mechanized Fain handling system consisted of a portable auger and a gate was developed and tested. The test results can be summarized as the following: 1) The loading capacity of the handling system developed is $16.2m^3/h$ (8.3 ton/h) for the Indica type rice and $13.0m^3/h$(7.3 ton/h) for the Japonica type. It is greater than that of manual handling as much as 2.5 - 2.7 times. 2) The unloading capacity of the handling system developed is $16.0m^3/h$(8.2 ton/h) for the Indica type rice and $12.6m^3/h$(7.0 ton/h) for the Japonica type. It is greater than that of the manual as much as 4.7 - 5.5 times. 3) For 3-ton capacity of the storage, the loading and unloading can be performed for 20 and 30 minutes by one man operation of equipment. while 60 and 120 minute for the manual of 2 men, respectively. 4) The volumetric efficiency of the system developed is 0.42 - 0.54 and the power efficiency is 4.0 - 4.4. 5) The break-even quantity of the handling system developed is about 38.6 ton($68.7m^3$) of rough rice and the initial investment for the system would be returned within five years for the most owners of the KAIST IBDS system.

  • PDF

The Effect on Logistics Cost of Incompatible Packaging Sizes in T-11 and T-12 pallet systems (T-11형 및 T-12형 파렛트 간 공용포장규격 미적용으로 인해 물류비에 미칠 수 있는 영향)

  • Jung, Sung-Tae;Yoon, Nam-Soo
    • Journal of Distribution Science
    • /
    • v.11 no.8
    • /
    • pp.15-23
    • /
    • 2013
  • Purpose - This is a case study aimed at finding a solution for improving the pallet loading efficiency in the process of delivering products through a transshipment using the T-11 and T-12 pallet systems. The study proposes a solution by demonstrating the case of a certain manufacturer A, who aims to reduce the logistics cost by using packaging sizes that are commonly applicable and can improve the compatibility between the T-11 pallet system, designated as the standard pallet in Korea, and the T-12 pallet system, which is commonly used in other foreign countries. The use of common sizes increases compatibility among the two systems and reduces both logistics and environmental costs. Thus, this case study calculates the quantitative benefits of applying common packaging sizes to improve the compatibility between the T-11 and T-12 pallet systems. These systems are considered to be the most important and widely used transportation systems in the global logistics industry. Research design, data, and methodology - This study examined manufacturer A's representative product and delivery system and assessed how manufacturer A was affected by the use of incompatible packaging sizes in the T-11 (1100 mm×1100 mm) and T-12 (1200mm×1000 mm) pallet systems, which were specified in the KS T 1002 standard. In addition, this study analyzed the impact of these packaging sizes on A's logistics cost. The TOPS program (Total Packaging System) was used to simulate pallet loading efficiency,and the main parameter studied was volume, as calculated from length, width, and height. Results - When the sizes of secondary packaging were not compatible across the T-11 and T-12 pallet systems, a reduction in loading efficiency was observed, leading to an increase in logistics cost during transshipment. Such low loading efficiencies led to a further loss of efficiency in transportation, storage and unloading. This may have a possible environmental impact with high social expenses, such as increased CO2 emissions. Hence, this study proposed that the KS T 1002 standard be amended to include 21 packaging sizes, including 7 sizes of the 600 mm×500 mm category, which are compatible with both the T-11 and T-12 pallet systems. Conclusions - This study found that the 69 standard sizes under the T-11 pallet system and the 40 standard sizes under the T-12 system in the KS T 1002 standard can be simplified and reduced to 21 mutually compatible packaging sizes, enabling logistics standardization and reducing national-level logistics costs. If the government pays attention to this study and considers the standardization of common sizes for the T-11 and T-12 pallet systems and amends the KS T 1002 standard, this study will deliver practical value to the global logistics industry, apart from being of academic significance.

Effect of a cell loading on the soft handoff of a DS-CDMA cellular system (Cell loading이 D-CDMA 셀룰러 시스템의 소프트 핸드오프에 미치는 영향)

  • 김경민;김남수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.8A
    • /
    • pp.1223-1230
    • /
    • 2000
  • In this paper, we proposed a handoff decision method based on signal-to-interference ratio(SIR) of the pilot channel in order to perform a handoff more effectively and to complement disadvantages - deterioration quality of a call, decreasing capacity of the system, and wasting power of the mobile station - which is caused when handoff is performed by the classical method that execute a handoff based on received signal strength. Moreover, when we change that the minimum threshold, the cell loading which is defined active traffic channels to total traffic channels ratio, and the fraction of the transmit power from base station allocated to the pilot channel on the forward link of a DS-CDMA system, we analyzed mean numbers of handoff depending on hysteresis level during the mobile station moving from one base station to another base station.

  • PDF

Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility (핵연료집합체 기계적특성 시험시설 구축과 기능시험)

  • Lee, Kang-Hee;Kang, Heung-Seok;Yoon, Kyung-Ho;Yang, Jae-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

Comparison of Traction Motor design and characteristics for battery driven hybrid tram (무가선 트램용 추진 전동기 설계 및 특성 비교)

  • Ham, Sang-Hwan;Kim, Kwang-Soo;Kim, Mi-Jung;Lee, Hyung-Woo;Lee, Ju
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1383-1388
    • /
    • 2010
  • The latest generation of tram is low-floor design, various nations in europe and japan have developed battery driven hybrid trams that combine battery and wiring. Battery driven tram system is achieved by contactless power supply system, thus system is needed high efficiency, high power and low weight traction motor for maximization of energy efficiency. Research from abroad is still in induction motor(IM) application, and it is not meet the efficiency and the power per unit volume in IPMSM. In this paper, we design compare IM and IPMSM to apply battery driven tram, and then compare these motors. To design the motor, we estimate the loading condition at first. Loading condition includes rolling resistance, air-drag resistance, and slope resistance. Based on the loading condition by estimation, we determine the power and compute rated voltage and rated current. In this paper, voltage is limited by battery voltage level. As a result, volume about IM is 1.98 times bigger than IPMSM under same condition. Even though IPMSM is bigger than IM in power density per volume, we consider more factors for actual application because there are demagnetization of permanent magnet in IPMSM and so on by external environment conditions.

  • PDF

A Study on Noise Source Identification for Loading Mechanism and Rattle noise about A/V System (차량용 A/V 시스템의 구동부 소음원과 래틀 소음원에 관한 연구)

  • 홍종호;강연준;이상호;이완우;이기석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.189-195
    • /
    • 2003
  • This paper represents an identification procedure for leading mechanism of a car A/V system which is composed of a DC motor and a set of plastic gears. In addition, we studied dominant noise source of rattle noise generated by external forced vibration as a car drives. we made a dynamometer to produce stationary operation on loading mechanism of A/V system because noise generated by actual loading mechanism is non-stationary signal. operating the dynamometer setup at various motor speeds, sound pressure spectra are measured and the results are analyzed. its dominant noise source is also identified by using a sound Intensity technique. we made use of multi-dimensional spectral analysis to rind a dominant rattle noise. this method is so useful to eliminate coherence between vibration sources and helps us obtain coherent output spectrum of individual vibration source which make a rattle noise.

  • PDF