• 제목/요약/키워드: Load-modulation

검색결과 326건 처리시간 0.029초

자기유도 무선전력전송시 진폭편이변조 제어가 가능한 양방향 자기장 무선통신 시스템 (Bidirectional Magnetic Wireless Communication System under Inductive Power Transfer capable of Amplitude-Shift Keying(ASK) Modulation Control)

  • 최병국;이은수;임춘택
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.275-281
    • /
    • 2016
  • A novel bidirectional magnetic wireless communication system is proposed in this study. This system provides the communication capability between the source and load sides by high-frequency signal while wireless power is transferred. Contrary to the conventional wireless communication systems using complex IC circuit and active components, the proposed system is simply composed of passive components. It is practical and beneficial for environmental robustness, cost effectiveness, and simple implementation. The detailed static analysis of the proposed system for power and communication lines is established. The proposed system is experimentally verified, and results show that a 0.1 voltage gain for communication line is obtained while a 2.0 voltage gain for the power line is achieved. The proposed system is adequate for practical applications as it allows the inductive power transfer system to wirelessly and easily communicate between the source and load sides.

A Single-Input Single-Output Approach by using Minor-Loop Voltage Feedback Compensation with Modified SPWM Technique for Three-Phase AC-DC Buck Converter

  • Alias, Azrita;Rahim, Nasrudin Abd.;Hussain, Mohamed Azlan
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.829-840
    • /
    • 2013
  • The modified sinusoidal pulse-width modulation (SPWM) is one of the PWM techniques used in three-phase AC-DC buck converters. The modified SPWM works without the current sensor (the converter is current sensorless), improves production of sinusoidal AC current, enables obtainment of near-unity power factor, and controls output voltage through modulation gain (ranging from 0 to 1). The main problem of the modified SPWM is the huge starting current and voltage (during transient) that results from a large step change from the reference voltage. When the load changes, the output voltage significantly drops (through switching losses and non-ideal converter elements). The single-input single-output (SISO) approach with minor-loop voltage feedback controller presented here overcomes this problem. This approach is created on a theoretical linear model and verified by discrete-model simulation on MATLAB/Simulink. The capability and effectiveness of the SISO approach in compensating start-up current/voltage and in achieving zero steady-state error were tested for transient cases with step-changed load and step-changed reference voltage for linear and non-linear loads. Tests were done to analyze the transient performance against various controller gains. An experiment prototype was also developed for verification.

Capacity Modulation of an Inverter Driven Heat Pump with Expansion Devices

  • Lee, Yong-Taek;Kim, Yong-Chan;Park, Youn-Cheol;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.60-68
    • /
    • 2000
  • An experimental study was peformed to investigate characteristics of an inverter driven heat pump system with a variation of compressor frequency and expansion device. The compressor frequency varied from 30Hz to 75Hz, and the performance of the system ap-plying three different expansion devices such as capillary tube, thermostatic expansion valve(TXV), and electronic expansion valve (EEV) was measured. The load conditions were altered by varying the temperatures of the secondary fluid entering condenser and evaporator with a constant flow rate. When the test condition was deviated from the standard value(rated value), TXV and EEV showed better performance than capillary tube due to optimal control of mass flow rate and superheat. In the present study, it was observed that the variable area expansion device had better performance than constant area expansion device in the inverter heat pump system due to active control of flow area with a change of com-pressor frequency and load conditions.

  • PDF

Design of Parallel-Operated SEPIC Converters Using Coupled Inductor for Load-Sharing

  • Subramanian, Venkatanarayanan;Manimaran, Saravanan
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.327-337
    • /
    • 2015
  • This study discusses the design of a parallel-operated DC-DC single-ended primary-inductor converter (SEPIC) for low-voltage application and current sharing with a constant output voltage. A coupled inductor is used for parallel-connected SEPIC topology. Generally, two separate inductors require different ripple currents, but a coupled inductor has the advantage of using the same ripple current. Furthermore, tightly coupled inductors require only half of the ripple current that separate inductors use. In this proposed work, tightly coupled inductors are used. These produce an output that is more efficient than that from separate inductors. Two SEPICs are also connected in parallel using the coupled inductors with a single common controller. An analog control circuit is designed to generate pulse width modulation (PWM) signals and to fulfill the closed-loop control function. A stable output current-sharing strategy is proposed in this system. An experimental setup is developed for a 18.5 V, 60 W parallel SEPIC (PSEPIC) converter, and the results are verified. Results indicate that the PSEPIC provides good response for the variation of input voltage and sudden change in load.

고전압 입력용 SMPS의 고효율 전략 (High Efficiency Strategy of High Input Voltage SMPS)

  • 우동영;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제22권3호
    • /
    • pp.365-371
    • /
    • 2019
  • Recently, the demonstration and research on the power transmission using high voltage DC such as HVDC(High Voltage DC), Smart Grid, DC transmission and distribution have been actively conducted. In order to control the power converter in high-voltage DC power transmission system, SMPS(Switching Modulation Power Supply) for power converter control using high-voltage DC input is essential. However, the demand for high-pressure SMPS is still low, so the development is not enough. In the low-output SMPS using the high-voltage input, it is difficult to achieve high efficiency due to the switching transient loss especially at light load. In this paper, we propose a new switching scheme for high power SMPS control for low output power. The proposed method can provide better efficiency increase effect in the light load region compared to the existing PWM method. To verify the feasibility of the proposed method, a 40 W SMPS for HVDC MMC(Modulation Multi-level Converter) was designed and verified by simulation.

일반화 공간변조를 위한 저복잡도 강인 최대 우도 신호 검파 (Low-Complexity Robust ML Signal Detection for Generalized Spatial Modulation)

  • 김정한;윤태선;오세훈;이경천
    • 한국정보통신학회논문지
    • /
    • 제21권3호
    • /
    • pp.516-522
    • /
    • 2017
  • 본 논문에서는 다중 안테나 구조 중 일부 송신 안테나만 활성화하고 활성 안테나의 인덱스를 통해 정보를 전송하는 일반화 공간변조(Generalized Spatial Modulation)시스템을 위한 최대우도 신호 검파 방법을 제안한다. 제안 최대 우도 수신기는 기존의 채널 정보 오차에 강인한 최대 우도 수신기와 비교하여 공분산 행렬을 추정할 때 후보 해 집합을 확률적으로 추출하여 공분산 행렬을 추정함으로써 시스템 복잡도를 크게 줄이도록 한다. 모의 실험을 통해 제안 최대 우도 수신기가 기존의 채널 정보 오차를 고려하지 않는 수신기보다 높은 수신 성능을 가지며, 기존 강인 최대우도 수신기와 비교하여 동일한 비트 오류율 성능을 가지면서도 큰 폭으로 계산 복잡도를 낮춤을 확인하였다.

유도가열기용 직.병렬 공진 고주파 인버터의 설계 (Design of High Frequency Inverter with Series-parallel Load-Resonant for Induction Heating application)

  • 홍순일;손의식
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.12-17
    • /
    • 2000
  • IN induction heating system the high frequency operation allows a rapid response to current fluctuation in the inverter and result in improved welding quality. To work induction heating of nonferrous metals, a welding power supply is need high working frequency and high power. This paper is shown design technique for increasing working frequency in induction heating for welding coppers. A series-parallel resonate inverter consists of H-type bridges, each of whose arms is composed of a combination of two parallel IGBTs. Inverter operating with the fixed frequency is controlled by pulse width modulation (PWM). As switching adapted the Zero-Voltage Switching technique to reduce switching losses the system is high efficiency. The propose inverter has feature which is high efficiency for very wide load variations with a narrow range of duty cycle ratio control and load short circuit capability. Detailed experimental results obtained from a 48[V] output, 500[W] experimental inverter are presented to verify the concept.

  • PDF

부한 환류모드를 갖는 새로운 반 브리지 공진형인버터 (A New Resonant H/B Inverter Having Load Freewheeling Modes)

  • 연재을;조규민;오원석;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.153-156
    • /
    • 2004
  • This paper presents a new circuit topology of the half-bridge resonant inverter. As the proposed half-bridge inverter can be operated in the load freewheeling modes, pulse width modulation (PWM) control method can be used for the output power control. The proposed half-bridge inverter should keep unity output displacement factor under the load-impedance varying conditions, if a new PWM control scheme based on the resonant frequency tracking algorithm is adopted. In this paper, electrical characteristics, and losses analysis of the proposed half-bridge resonant inverter are described. Simulation and experimental results of the prototype experimental setup to verify the validity of the proposed half-bridge resonant inverter are presented and discussed.

  • PDF

High Performance Current Controller for Sparse Matrix Converter Based on Model Predictive Control

  • Lee, Eunsil;Lee, Kyo-Beum;Lee, Young Il;Song, Joong-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1138-1145
    • /
    • 2013
  • A novel predictive current control strategy for a sparse matrix converter is presented. The sparse matrix converter is functionally-equivalent to the direct matrix converter but has a reduced number of switches. The predictive current control uses a model of the system to predict the future value of the load current and generates the reference voltage vector that minimizes a given cost function so that space vector modulation is achieved. The results show that the proposed controller for sparse matrix converters controls the load current very effectively and performs very well through simulation and experimental results.

연속 웨이블렛 변환의 확대된 위상 지도를 이용한 기어의 초기 퍼팅 결함 진단 (Fault Detection of a Gear with Initial Pitting using the Boomed Phase Map of Continuous Wavelet Transform)

  • 이상권;심장선
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1759-1766
    • /
    • 2001
  • Vibration transient generated by developing localized fault in gear can be used as indicators in gear fault detection. In this paper, we propose the zoomed phase map for a fault signal using continuous wavelet transfers to detect this vibration transient. Local fault induces the abrupt fluctuation of load exciting tooth and phase lag in the vibration signal measured on the gearbox. The relatively large fault like "tip breakage" easily can be detected by the clear fluctuation of exciting load. However, minor fault like "initial pitting"cannot be detected using the load fluctuation. To defect this kind of minor fault, the phase map for a fault signal is taken into account. The phase lag by minor fault is observed well in the zoomed phase map.