• 제목/요약/키워드: Load-modulation

검색결과 326건 처리시간 0.025초

Theoretical Analysis and Control of DC Neutral-point Voltage Balance of Three-level Inverters in Active Power Filters

  • He, Yingjie;Liu, Jinjun;Tang, Jian;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.344-356
    • /
    • 2012
  • In recent years, multilevel technology has become an effective and practical solution in the field of moderate and high voltage applications. This paper discusses an APF with a three-level NPC inverter. Obviously, the application of such converter to APFs is hindered by the problem of the voltage unbalance of DC capacitors, which leads to system instability. This paper comprehensively analyzes the theoretical limitations of the neutral-point voltage balancing problem for tracking different harmonic currents utilizing current switching functions from the space vector PWM (SVPWM) point of view. The fluctuation of the neutral point caused by the load currents of certain order harmonic frequency is reported and quantified. Furthermore, this paper presents a close-loop digital control algorithm of the DC voltage for this APF. A PI controller regulates the DC voltage in the outer-loop controller. In the current-loop controller, this paper proposes a simple neutral-point voltage control method. The neutral-point voltage imbalance is restrained by selecting small vectors that will move the neutral-point voltage in the direction opposite the direction of the unbalance. The experiment results illustrate that the performance of the proposed approach is satisfactory.

고효율 오존생기용 고주파 공진형 인버터의 특성 해석 (Analysis of high-frequency resonant Inverter character using efficient ozonizer)

  • 김영훈;황영민;노인배;김영빈;허태원;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.246-248
    • /
    • 2002
  • This paper presents a high-frequency voltage source inverter for silent corona discharge ozonizer application, which is characterized by the power control based on pulse density modulation (PDM). The PDM inverter produces either a square -wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant do voltage and operating frequency. This results in a wide range of power control in the silent corona discharge load with a strong nonlinear characteristics. And proposed addition circuit for maintain discharge on the center of the airgap. In this paper, schemed equivalent electric circuit of the discharge electrode for simulation. Finally, the effectiveness of this discharge tube character of silent corona ozonizer is investigated in the simulation results.

  • PDF

Numerical prediction of pressure pulsation amplitude for different operating regimes of Francis turbine draft tubes

  • Lipej, Andrej;Jost, Dragica;Meznar, Peter;Djelic, Vesko
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.375-382
    • /
    • 2009
  • Hydraulic instability associated with pressure fluctuations is a serious problem in hydraulic machinery. Pressure fluctuations are usually a result of a strong vortex created in the centre of a flow at the outlet of a runner. At every radial turbine and also at every single regulating axial turbine, the draft tube vortex appears at part-load operating regimes. The consequences of the vortex developed in the draft tube are very unpleasant pressure pulsation, axial and radial forces and torque fluctuation as well as turbine structure vibration. The consequences of the vortex are transferred upstream and downstream with amplitude and frequency modulation in respect of the turbine operating regime, cavitation conditions and air admitted content. Numerical prediction of the vortex appearance in the design stage is a very important task. The amplitude of the pressure pulsation is different for each operating regime therefore the main goal of this research was to numerically predict pressure pulsation amplitude versus different guide vane openings and to compare the results with experimental ones. For the numerical flow analysis of a complete Francis turbine (FT), the computer code ANSYS-CFX11 has been used.

저속영역에서 속도검출기가 없는 유도전동기의 강인성 적응제어 시스템 (Robust Adaptive Control System for Induction Motor Drive Without Speed Sensor at Low Speed)

  • 김민회
    • 한국산업융합학회 논문집
    • /
    • 제2권2호
    • /
    • pp.91-102
    • /
    • 1999
  • The paper describes a robust adaptive control algorithm for induction motor drive without speed sensor at low speed range. The control algorithm use only current sensors in a space vector pulse width modulation within loop control with rotor speed estimation and voltage source inverter. On-line rotor speed estimation is based on utilizing parallel model reference adaptive control system. MRAC of the modified flux model for flux and rotor speed estimator uses dual-adaptation mechanism, ${\omega}_r$ and ${\omega}_e$ scheme. The estimated flux components in the model can be compensated from the effects of offset errors on pure integrals. It can be compensated to the parameter variations and torque fluctuation with speed estimation in less then 10 rad/sec. In a simulation, the proposed induction motor control algorithm without speed sensor at very low speed range are shown to operate very well in spite of variable rotor time constant and fluctuating load without change the controller parameters. The suggested control strategy and estimation method have been validated by simulation study, and it proposed the designed system for the implementation using TI320C31 DSP/ASIC controller.

  • PDF

발전소 대형 입형펌프 전동기의 전류/진동신호 특성 분석 (Current and Vibration Characteristics Analysis of Induction Motors for Vertical Pumps in Power Plant)

  • 배용채;이현;김연환
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.404-413
    • /
    • 2006
  • Induction motors are the workhorse of our industry because of their versatility and robustness. The diagnosis of mechanical load and power transmission system failures is usually carried out through mechanical signals such as vibration signatures, acoustic emissions, motor speed envelope. The motor faults including mechanical rotor imbalances, broken rotor bar, bearing failure and eccentricities problems are reflected in electric, electromagnetic and mechanical quantities. The recent research has been directed toward electrical monitoring of the motor with emphasis on inspecting the stator current of the motor, The stator current spectrum has been widely used for fault detection in induction motor systems. The motor current signature analysis is the useful technique to assess machine electrical condition. This paper describes the motor condition detected by the current signatures Paralleled with vibration signatures analysis of induction motors with the roller bearing and the journal bearing type for large vertical pumps in power plant as examples to discuss for motor fault detection and diagnosis.

유도전동기의 고정자 전류에 미치는 베어링 고장 영향 분석 (Analysis of the Bearing Fault Effect on the Stator Current of an AC Induction Motor)

  • 김재훈;이동익
    • 제어로봇시스템학회논문지
    • /
    • 제20권6호
    • /
    • pp.635-640
    • /
    • 2014
  • Detection and diagnosis of incipient bearing fault in an induction motor is important for the prevention of serious motor failure. This paper presents an analysis of the effect of a faulty bearing on the stator current of an induction motor. A bearing fault leads to torque oscillations which result in phase modulation of the stator current. Since the torque oscillations cause specific frequency components at the stator current spectrum to rise sharply, the bearing fault can be detected by checking out the faultrelated frequency. In this paper, a mathematical model of the load torque oscillation caused by a bearing fault is presented. The proposed model can be used to analyze the physical phenomenon of a bearing fault in an induction motor. In order to represent the bearing fault effect, the proposed model is combined with an existing model of vector-controlled induction motors. A set of simulation results demonstrate the effectiveness of the proposed model and represent that bearing fault detection using a stator current is useful for vector-controlled induction motors.

고주파 결합 인덕터 직렬 공진형 ZCS-PFM 초퍼 제어 방식을 이용한 새로운 승압형 DC-DC 컨버터 (A Novel Boost DC-DC Converter using High Frequency Coupled Inductor Series Resonant ZCS-PFM Chopper Control Method)

  • 김홍신;허영환;문상필;박한석
    • 전기학회논문지P
    • /
    • 제66권2호
    • /
    • pp.63-68
    • /
    • 2017
  • This paper proposes a new non-isolated DC conversion circuit topology of the voltage source coupled inductor series resonant high-frequency PFM controlled boost chopper type DC-DC power converter using two in one IGBT power module, which can efficiently operate under a principle of zero current soft switching for wide output regulation voltage setting ranges and wide fluctuation of the input DC side voltage as well as the load variation ranges. Its steady state operating principle and the output voltage regulation characteristics in the open-loop-based output voltage control scheme without PI controller loop are described and evaluated from theoretical and experimented viewpoints. Finally, in this paper the computer-aided simulation steady-state analysis and the experimental results are presented in order to prove the effectiveness and the validity of voltage regulation characteristics of the proposed series resonant zero current soft switching boost chopper type DC-DC power converter circuit using IGBTs which is based on simple pulse frequency modulation strategy more than, 20kHz.

Analysis, Design and Implementation of a Soft Switching DC/DC Converter

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.20-30
    • /
    • 2013
  • This paper presents a soft switching DC/DC converter for high voltage application. The interleaved pulse-width modulation (PWM) scheme is used to reduce the ripple current at the output capacitor and the size of output inductors. Two converter cells are connected in series at the high voltage side to reduce the voltage stresses of the active switches. Thus, the voltage stress of each switch is clamped at one half of the input voltage. On the other hand, the output sides of two converter cells are connected in parallel to achieve the load current sharing and reduce the current stress of output inductors. In each converter cell, a half-bridge converter with the asymmetrical PWM scheme is adopted to control power switches and to regulate the output voltage at a desired voltage level. Based on the resonant behavior by the output capacitance of power switches and the transformer leakage inductance, active switches can be turned on at zero voltage switching (ZVS) during the transition interval. Thus, the switching losses of power MOSFETs are reduced. The current doubler rectifier is used at the secondary side to partially cancel ripple current. Therefore, the root-mean-square (rms) current at output capacitor is reduced. The proposed converter can be applied for high input voltage applications such as a three-phase 380V utility system. Finally, experiments based on a laboratory prototype with 960W (24V/40A) rated power are provided to demonstrate the performance of proposed converter.

DC 마이크로 그리드를 위한 Three-port Dual Active Bridge DC-DC 컨버터의 독립 전력 제어 (Decoupled Power Control of Three-port Dual Active Bridge DC-DC Converter for DC Microgrid Systems)

  • 심주영;이준영;최현준;김학선;정지훈
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.366-372
    • /
    • 2018
  • Three-port dual-active bridge (DAB) converter in a DC microgrid was studied due to its high power density and cost-effectiveness. The other advantages of DAB include galvanic isolation and bidirectional power conversion capability using simple control modulation. The three-port DAB converter consists of a three winding transformer and three bridges. The transformer has three phases, which means that the ports are coupled. Thus, the three-port DAB converter causes unwanted power flows when the load connected to each port changes. The basic operational principles of the three-port DAB converter are presented in this study. The decoupling control strategy of the independent port power transfer is presented with a mathematical power model to overcome the unexpected power flow problem. The validity of the proposed analysis and control strategy is verified with PSIM simulation and experiments using a 1-kW prototype power converter.

3상 DAB 컨버터의 경부하 효율 향상을 위한 스위칭 알고리즘 연구 (Switching Algorithm for Improving Power Conversion Efficiency of Three-Phase Dual Active Bridge Converter under Light Load Conditions.)

  • 최현준;이준영;심주영;정지훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.111-113
    • /
    • 2018
  • 본 논문에서는 3상 듀얼 액티브 브리지 (3P-DAB) 컨버터의 경부하 조건에서 전력 변환 효율을 향상시키기 위한 효과적인 스위칭 알고리즘을 제안한다. 3P-DAB 컨버터는 교차배치 (Interleave) 구조로 인한 작은 필터 크기와 낮은 전도 손실을 얻을 수 있고, 추가적인 회로없이 소프트 스위칭이 가능하며 양방향 전력 흐름에서의 무절체 제어로 인해 고전력 애플리케이션에서 널리 사용되는 토폴로지 중 하나이다. 그러나 3P-DAB의 위상천이 방법(SPS)을 이용한 제어 방식의 경우 경부하 조건에서 영전압 스위칭(ZVS)의 실패 가능성이 높기때문에 효과적이지 않다. 본 논문에서는 SPS 제어 알고리즘과 비대칭 시비율 변조법 (Asymmetrical Pulse Width Modulation; APWM)을 연쇄적으로 사용하여, 경부하에서 스위치의 ZVS 영역을 넓히고자 한다. 3-kW의 3상 DAB 컨버터의 시작품을 구현하고 실험을 통해 제안된 방법의 효율성을 검증 하였다.

  • PDF