• 제목/요약/키워드: Load transient

검색결과 778건 처리시간 0.027초

자기 구동 능동 클램프 포워드 컨버터의 대신호 과도 특성 해석 (Large-Signal Transient Analysis of a Self-Driven Active-Clamp Forward Converter)

  • 봉상철;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1235-1238
    • /
    • 2004
  • This paper presents the large-signal transient analysis of a self-driven active-clamp forward converter, eliminating the extra drive circuit for the active clamp switch. The operation principle of the converter was presented and experiential results were used to verify the analyzed results. A 50-W prototype converter built and tested it. From the tested results, input transient response and load transient response of the converter were established.

  • PDF

보상형 퍼지 제어기 설계에 관한 연구 (A Study on the Design of Compensated Fuzzy Controller)

  • 추연규;탁한호
    • 한국항해학회지
    • /
    • 제24권3호
    • /
    • pp.141-145
    • /
    • 2000
  • In servo-system which need fast response and accuracy, PID controller has a good steady-state performance, but has a poor transient response performance causing a load be changed. Compared to these features, FLC(Fuzzy Logic Controller) has a good transient response performance for changed load, but has a little Poor steady-state performance. In this paper, Compensated Fuzay Controller which consists of PID controller and FLC is proposed to modify these disadvantages and is examined through simulation to evaluate its functions.

  • PDF

지중송전 및 배전계통의 공통접지에 따른 과도상태 영향 분석 (Analysis of Effect on the Transient State According to Common Grounding between Underground Transmission Systems and Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.740-741
    • /
    • 2007
  • This paper analyses the transient state of underground distribution system against single line to ground fault in underground transmission systems, when underground transmission systems and distribution systems are made of common grounding. Underground transmission systems and distribution systems are modeled by EMTP/ATPDraw. Simulation is carried out considering variation of parameters such as value of common grounding, balance load and unbalance load.

  • PDF

Characteristics of Synchronous and Asynchronous modes of fluctuations in Francis turbine draft tube during load variation

  • Goyal, Rahul;Cervantes, Michel J.;Gandhi, Bhupendra K.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권2호
    • /
    • pp.164-175
    • /
    • 2017
  • Francis turbines are often operated over a wide load range due to high flexibility in electricity demand and penetration of other renewable energies. This has raised significant concerns about the existing designing criteria. Hydraulic turbines are not designed to withstand large dynamic pressure loadings on the stationary and rotating parts during such conditions. Previous investigations on transient operating conditions of turbine were mainly focused on the pressure fluctuations due to the rotor-stator interaction. This study characterizes the synchronous and asynchronous pressure and velocity fluctuations due to rotor-stator interaction and rotating vortex rope during load variation, i.e. best efficiency point to part load and vice versa. The measurements were performed on the Francis-99 test case. The repeatability of the measurements was estimated by providing similar movement to guide vanes twenty times for both load rejection and load acceptance operations. Synchronized two dimensional particle image velocimetry and pressure measurements were performed to investigate the dominant frequencies of fluctuations, vortex rope formation, and modes (rotating and plunging) of the rotating vortex rope. The time of appearance and disappearance of rotating and plunging modes of vortex rope was investigated simultaneously in the pressure and velocity data. The asynchronous mode was observed to dominate over the synchronous mode in both velocity and pressure measurements.

Elastic Wave Propagation in Monoclinic System Due to Transient Line Load

  • Kim, Yong-Yun
    • The Journal of the Acoustical Society of Korea
    • /
    • 제17권2E호
    • /
    • pp.53-58
    • /
    • 1998
  • In this paper, we study the response of several anisotropic systems to buried transient line loads. The problem is mathematically formulated based on the equations of motion in the constitutive relations. The load is in form of a normal stress acting with arbitrary axis on the plane of monoclinic symmetry. Plane wave equation is coupled with vertical shear wave, longitudinal wave and horizontal shear wave. We first considered the equation of motion in reference coordinate system, where the line load is coincident with symmetry axis of the orthotrioic material. Then the equation of motion is transformed with respect to general coordiante system with azimuthal angle by using transformation tensor. The load is first described as a body force in the equations of the motion for the infinite media and then it is mathematically characterized. Subsequently the results for semi-infinite spaces is also obtained by using superposition of the infinite medium solution together with a scattered solution from the free surface. Consequently explicit solutions for the displacements are obtained by using Cargniard-DeHoop contour. Numerical results which are drawn from concrete examples of orthotropic material belonging to monoclinic symmetry are demonstrated.

  • PDF

홀로그래피를 이용한 정전집진기 집진판의 진동 특성 연구 (A Study on the Vibration Characteristics of Collecting Plate in the Electrostatic Precipitator Using Holograpy)

  • 나종문;이기백;양장식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권1호
    • /
    • pp.56-66
    • /
    • 1996
  • In this study, the characteristics of generation and propagarion of transient wave induced in the assembly of four collecting plate upon the propagation of waves are analyzed. Also double exposure holographic inteferometry using ruby pulse laser is built in order to investigate the propagation of transient waves generated by impact load. When impact load was applied at edge of connecting band, the vibration of collecting plates was generated from the contact points between collecting plate and band which connects four collecting plates. Waves generated from the lower part and those reflected from the upper part were mixed as time went on and then formed very complex shapes. Also, when impact load was aplied at center of collecting plate, the waves propagating across the convexo-concave plane were reflected partly at curved section. Therefore the vibration amplitude was decreased as the transiet waves were propagated through the convexo-concave plane.

  • PDF

저온수를 이용하는 일중효용/이단승온 리튬브로마이드-물 흡수식 시스템의 동적 해석 (Dynamic Analysis of Single-Effect/Double-Lift Libr-Water Absorption System using Low-Temperature Hot Water)

  • 김병주
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.695-702
    • /
    • 2009
  • Dynamic behavior of Libr-water absorption system using low-temperature hot water was investigated numerically. Thermal-hydraulic model of single-effect/double-lift 100 RT chiller was developed by applying transient conservation equations of total mass, Libr mass, energy and momentum to each component. Transient variations of system properties and transport variables were analysed during start-up operation. Numerical analysis were performed to quantify the effects of bulk concentration and part-load operation on the system performance in terms of cooling capacity, coefficient of performance, and time constant of system. For an absorption chiller considered in the present study, optimum bulk concentration was found to exist, which resulted in the minimum time constant with stable cooling capacity. COP and time constant increased as the load decreased down to 40%, below which the time constant increased abruptly and COP decreased as the load decreased further.

과도현상 해석을 위한 EAFs 부하 무델의 개발 (An Electric Arc Furnaces Load Model for Transient Analysis)

  • 장길수;;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.197-202
    • /
    • 1999
  • Electric arc furnaces (EAFs) use bulk electrical energy to create heat in metal refining industries. The electric arc process is a main cause of the degradation of the electric power quality such as voltage flicker due to the interaction of the high demand currents of the load with the supply system impedance. The stochastic models have described the aperiodic physical phenomena of EAFs. An alternative approach is to include deterministic chaos in the characterization of the arc currents. In this parer, a chaotic approach to such modeling is described and justified. At the same time, a DLL(Dynamic Link Library) module, which is a FORTRAN interface with TACS (Transient Analysis of Control Systems), is developed to implement the chaotic load model in the Electromagnetic Transients Program (EMTP). The details of the module and the results of tests performed on the module to verify the model and to illustrate its capabilities are presented in this paper.

  • PDF

Transient dynamic analysis of sandwich beam subjected to thermal and pulse load

  • Layla M. Nassir;Mouayed H.Z. Al-Toki;Nadhim M. Faleh;Hussein Alwan Khudhair;Mamoon A.A. Al-Jaafari;Raad M. Fenjan
    • Steel and Composite Structures
    • /
    • 제51권1호
    • /
    • pp.1-8
    • /
    • 2024
  • Transient dynamic behavior of a sandwich beam under thermal and impulsive loads has been researched in the context of higher-order beam theory. The impulse load of blast type has been enforced on the top exponent of the sandwich beam while it is in a thermal environment. The core of the sandwich beam is cellular with auxetic rectangular pattern, whereas the layers have been built with the incorporation of graphene oxide powder (GOP) and are micromechanically introduced through Halpin-Tsai formulization. Governing equations for the sandwich beam have been solved through inverse Laplace transform style for obtaining the dynamical deflections. The connection of beam deflections on temperature variability, GOP quantity, pulse load situation and core relative density has been surveyed in detail.

제20회 CIGRE대회 보고

  • 대한전기학회편집부
    • 전기의세계
    • /
    • 제14권2호
    • /
    • pp.50-52
    • /
    • 1965
  • 본 고에서는 연속부하의 전류용량 산출 방법에 대하여 보고서가 완성되었고 금후 cyclic load의 경우 및 transient load의 경우에 대하여 산출 방법의 표준작성이 착수되고 있다는 보고가 있었다. 또 cable의 축방향으로 열저항이 변하는 경우의 산출방법에 대하여도 자료가 제출되었다.

  • PDF