• Title/Summary/Keyword: Load rejection

Search Result 113, Processing Time 0.017 seconds

The Design and Measurements of 100/150 GHz Band Single Side Band Filters by Using Rotated Polarization (편파 회전을 이용한 100/150 GHz 대역용 단측파대 여파기의 제작 및 성능측정)

  • Park, Jong-Ae;Han, Seog-Tae;Kim, Tai-Seong;Kim, Kwang-Dong;Kim, Hyo-Ryong;Chung, Hyun-Su;Cho, Se-Hyung;Yang, Jong-Man
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.2
    • /
    • pp.20-30
    • /
    • 1999
  • We have made the single side hand filter for the dual channel receiver which is a heterodyne receiver to observe the cosmic radio waves with 100GHz band ranged from 85GHz to 115GHz and 150GHz band ranged from 125GHz to 175GHz simultaneously. We have introduced the filter theory using the principle of the Martion-Puplett interferometer, which has the characteristics of rotated polarization. To reduce the loss of the transmission and beam coupling which are caused from the path difference associated with the intermediate frequency the design and the implementation have been intensely considered. The receiver needs two filters with different characteristics each other. Because each of them has the optimum positions as a function frequency at which the signal frequency is fed to mixer and the image frequency is rejected to the image termination load. The intermediate frequency and its band width have been also evaluated. We have measured the property of two filters using the vector network analyser and the beam measurement system which is made by us. The responses of the filter as a function of the position and the frequency are compared with the theory. It is shown that not only the measured values are very close to the theoretical values, but also the image rejection ratios are better than 22dB for both filters. Through successful observation using a dual channel receiver with two manufactured filters, the performance of the filters has finally verified.

  • PDF

PR Controller Based Current Control Scheme for Single-Phase Inter-Connected PV Inverter (PR제어기를 이용한 단상 계통 연계형 태양광 인버터 설계)

  • Vu, Trung-Kien;Seong, Se-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3587-3593
    • /
    • 2009
  • Nowadays, the PV systems have been focused on the interconnection between the power source and the grid. The PV inverter, either single-phase or three-phase, can be considered as the core of the whole system because of an important role in the grid-interconnecting operation. An important issue in the inverter control is the load current regulation. In the literature, the Proportional+Integral (PI) controller, normally used in the current-controlled Voltage Source Inverter (VSI), cannot be a satisfactory controller for an ac system because of the steady-sate error and the poor disturbance rejection, especially in high-frequency range. By comparison with the PI controller, the Proportional+Resonant (PR) controller can introduce an infinite gain at the fundamental ac frequency; hence can achieve the zero steady-state error without requiring the complex transformation and the dq-coupling technique. In this paper, a PR controller is designed and adopted for replacing the PI controller. Based on the theoretical analyses, the PR controller based control strategy is implemented in a 32-bit fixed-point TMS320F2812 DSP and evaluated in a 3kW experimental prototype Photovoltaic (PV) power conditioning system (PCS). Simulation and experimental results are shown to verify the performance of implemented control scheme in PV PCS.

Comparison of PI and PR Controller Based Current Control Schemes for Single-Phase Grid-Connected PV Inverter (단상 계통 연계형 태양광 인버터에 사용되는 PI 와 PR 전류제어기의 비교 분석)

  • Vu, Trung-Kien;Seong, Se-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2968-2974
    • /
    • 2010
  • Nowadays, the PV systems have been focused on the grid connection between the power source and the grid. The PV inverter can be considered as the core of the whole system because of an important role in the grid-interfacing operation. An important issue in the inverter control is the load current regulation. In the literature, Proportional Integral (PI) controller, which is normally used in the current-controlled Voltage Source Inverter (VSI), cannot be a satisfactory controller for an AC system because of the steady-sate error and the poor disturbance rejection, especially in high-frequency range. Compared with conventional PI controller, Proportional Resonant (PR) controller can introduce an infinite gain at the fundamental frequency of the AC source; hence it can achieve the zero steady-state error without requiring the complex transformation and the de-coupling technique. Theoretical analyses of both PI and PR controller are presented and verified by simulation and experiment. Both controller are implemented in a 32-bit fixed-point TMS320F2812 DSP processor and evaluated on a 3kW experimental prototype PV Power Conditioning System (PCS). Simulation and experimental results are shown to verify the controller performances.