• Title/Summary/Keyword: Load management

Search Result 2,138, Processing Time 0.027 seconds

The Effect of Shoulder and Elbow Postures with External Loads on the Perceived Discomfort (어깨와 팔꿈치의 조합자세 및 외부부하가 지각불편도에 미치는 영향)

  • Kim, Dong-Jin;Na, Seok-Hee;Park, Guk-Mu
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.145-151
    • /
    • 2006
  • The objective of this study is to investigate the perceived discomfort for postures combined with shoulder flexion/extension and elbow flexion, and external load. 12 healthy male undergraduate and graduate students participated in this experiment. Experimental variables were the shoulder flexion/extension angle(-20°, 0°, 45°, 90°, 135°), the elbow flexion angle (0°, 45°, 120°), and the external load(0, 1.5Kg, 3Kg) as independent variables and a whole body perceived discomfort using Borg's CR10 as a dependent variable. The subjects maintained the given posture for 60 seconds and then rated the perceived discomfort. The ANOVA results showed that all main factors and two-way interactions were statistically significant at α=0.05. As a result of regression analysis to examine the effect of external load on the perceived discomfort, the perceived discomfort linearly increased as the level of external load increased. Then, the effect of external load on the perceived discomfort was quantitatively classified into three levels based on the result of regression analysis.

A Study on the Estimations Method of Demand-Side Management Cost Per kW and/or kWh to Find Reasonable Load Factor (전력시스템 적정 부하율 산정을 위한 단위당 수요관리비용 추정 방안 연구)

  • Hwang, Sung-Wook;Kim, Jung-Hoon;Jung, Young-Beom;Yoon, Yong-Beum
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.26-28
    • /
    • 2007
  • To estimate reasonable load factor of power system both supply side and demand side of views should be considered. In the case of this study the demand side is considered and it is supposed that load curves depends on the load factor. The key point of this study is that the cost of demand-side management program per kW and/or kWh should be calculated.

  • PDF

Mathematical Model for File Migration and Load Balancing in Distributed Systemsc (분산 시스템에서 파일 이전과 부하 균등을 위한 수학적 모델)

  • Moon, Wonsik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.4
    • /
    • pp.153-162
    • /
    • 2017
  • Advances in communication technologies and the decreasing cost of computers have made distributed computer systems an attractive alternative for satisfying the information needs of large organizations. This paper presents a distributed algorithm for performance improvement through load balancing and file migration in distributed systems. We employed a sender initiated strategy for task migration and used learning automata with several internal states for file migration. A task can be migrated according to the load information of a computer. A file is migrated to the destination processor when it is in the right boundary state. We also described an analytical model for load balancing with file migration to verify the proposed algorithm. Analytical and simulation results show that our algorithm is very well-suited for distributed system environments.

A Study on the Building Energy Analysis and Algorithm of Energy Management System (건물 에너지 분석 및 에너지 관리 시스템 알고리즘에 관한 연구)

  • Han, Byung-Jo;Park, Ki-Kwang;Koo, Kyung-Wan;Yang, Hai-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.505-510
    • /
    • 2009
  • In this paper, building energy analysis and energy cost of power stand up and demand control over the power proposed to reduce power demand. Through analysis of the load power demand special day were able to apply the pattern. In addition, the existing rate of change of load forecasting to reduce the large errors were not previously available data. And daily schedules and special day for considering the exponential smoothing methods were used. Previous year's special day and the previous day due to the uncertainty of the load and the model components were considered. The maximum demand power control simulation using the fuzzy control of power does not exceed the contract. Through simulation, the benefits of the proposed energy-saving techniques were demonstrated.

Balancing Loads on SONET Rings without Demand Splitting

  • Lee, Chae-Y.;Chang, Seon-G.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.22 no.2
    • /
    • pp.303-311
    • /
    • 1996
  • The Self Healing Ring (SHR) is one of the most Intriguing schemes which provide survivability for telecommunication networks. To design a cost effective SONET ring it is necessary to consider load balancing problems by which the link capacity is determined. The load balancing problem in SONET ring when demand splitting is not allowed is considered in this paper. An efficient algorithm is presented which provides the best solution starting from various Initial solutions. The initial solution is obtained by routing ell demands such that no demands pass through an are In the ring. The proposed algorithm iteratively improves the Initial solution by examining each demand and selecting the maximum load are in its path. The demand whose maximum arc load is biggest is selected to be routed in opposite direction. Computational results show that the proposed algorithm is excellent both in the solution quality and in the computational time requirement. The average error bound of the algorithm is 0.11% of the optimum and compared to dual-ascent approach which has good computational results than other heuristics.

  • PDF

Optimal unidirectional grid tied hybrid power system for peak demand management

  • Vineetha, C.P.;Babu, C.A.
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.47-68
    • /
    • 2016
  • A well designed hybrid power system (HPS) can deliver electrical energy in a cost effective way. In this paper, model for HPS consisting of photo voltaic (PV) module and wind mill as renewable energy sources (RES) and solar lead acid battery as storage device connected to unidirectional grid is developed for peak demand reduction. Life time energy cost of the system is evaluated. One year hourly site condition and load pattern are taken into account for analysing the HPS. The optimal HPS is determined for least life time energy cost subject to the constraints like state of charge of the battery bank, dump load, renewable energy (RE) generation etc. Optimal solutions are also found out individually for PV module and wind mill. These three systems are compared to find out the most feasible combination. The results show that the HPS can deliver energy in an acceptable cost with reduced peak consumption from the grid. The proposed optimization algorithm is suitable for determining optimal HPS for desired location and load with least energy cost.

A Study on Network Load Management in MANET (MANET 환경에서의 네트워크 부하관리에 관한 연구)

  • Kang, Kyeong-In;Bae, Park-Kyong;Jung, Chan-Hyeok
    • Journal of IKEEE
    • /
    • v.7 no.2 s.13
    • /
    • pp.127-134
    • /
    • 2003
  • Ad Hoc Networks, autonomous distributed network using routing scheme, does not operate properly owing to multi flow service when network load increases at specific network node. In this paper, we suggest traffic management routing protocol in Ad Hoc Network to reduce network traffic congestion and distribute network load in data transmission. Through test results of proposed algorithm under NS(Network Simulator)simulator environments . we acquired reduced network load and increased data transmission rate.

  • PDF

Direct Load Control System for Air-conditioner (에어컨부하 직접 제어시스템 실용화 연구)

  • Ko, Sang-Cheon;Lee, Sang-Yun;Kim, Myong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3051-3053
    • /
    • 1999
  • In recent years, it becomes a worldwide trend that the power utilities focus their attention to Demand Side Management. Increasing Electric power consumption, they adopt a direct load management to accomplish low cost and stability of electric supply. Following this trend, KEPCO is researching a Direct Load Control System for Air Conditioner. This Paper presents the development results of the Direct Load Control System to Control electric power consumption of Conditioner in summer period this year.

  • PDF

A Situations and Improvements on the Rail Freight System (철도화물수송체계의 현황과 개선방안)

  • 이용상
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.37-48
    • /
    • 2004
  • In this paper, I explain the situations and problems which are focused on the rail freight system. We have a many problems, which have been showed the long freight logistics time, and inadequate fare system. And rail freight system does not have a efficient marketing system, and unit load system. Therefore rail freight has been decreased modal share, which is estimated from 9.65% in 1995 to 6.25% in 2001(ton base). Recently, EU nations and America rail freight system reveals a good outcome, which keeps the balance in the black. The main factors which go into the black, is the enlargement the investment in rail freight and efficient management focusing on the unit load system, fare system, and personnel management. I suggest the several improvement ways, which will be helpful to advance the rail freight system. Fistly, I suggest the speed up the freight rail and efficient fare system. Secondly, I propose the unit load system and the regulation the truck focusing on curtailment of the social cost. Lastly, I make an overture of establishment the comprehensive logistics system.

Monotonic Loading Tests on Seismic Stiffeners for Vertical Hangers (수직 행거 내진설계용 스티프너의 단조 압축 실험)

  • Chang-Soo Oh;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.187-192
    • /
    • 2023
  • In piping systems, trapeze hangers are subjected to vertical and horizontal seismic loads and stiffeners are used. In this study, monotonic compression tests were conducted with the removable stiffeners using three variables: stiffener clamp fixing position, section length, and installation direction. The maximum load reinforced with stiffeners could withstand a compressive load of 11kN by applying a safety factor of 10%. It could be estimated that the fixing clamp spacing or the length of shape and load had a proportional relationship. And the stiffener must be fixed in the direction of the strong axis on hinge parts. Also the stiffener buckiling load design proposes to use a method of calculate the flexural buckling compressive strength of and unreinforced full threaded bolt.