• Title/Summary/Keyword: Load limiter

Search Result 65, Processing Time 0.022 seconds

The Study on Reducing Voltage Sags Due to The Distribution System Faults (배전계통 사고에 의한 전압저하 저감방법에 관한 연구)

  • 김진성;오용택;노대석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.88-96
    • /
    • 2004
  • The sag is phenomenon that magnitude of load voltage temporarily decreases because of power system fault. If a certain equipment in industrial process have any trouble result from sag, it can cause utility to be charged for enormous economics loss. Therefore it need to analyze the characteristic of sag and then mitigation method for sags in distribution system in oder to increase reliability. This paper suggests a sags mitigation method with concentrating on mitigation-device interface method, especially FCL that is Fault Current Limiter. And this effect has been done using PDCAD/EMTDC computer simulation analysis.

Characteristics of the magnetic flux-offset type FCL by switching component

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.18-20
    • /
    • 2016
  • The study of superconducting fault current limiter (SFCL) is continuously being studied as a countermeasure for reducing fault-current in the power system. When the fault occurred in the power system, the fault-current was limited by the generated impedance of SFCLs. The operational characteristics of the flux-offset type SFCL according to turn ratios between the primary and the secondary winding of a reactor were compared in this study. We connected the secondary core to a superconductor and a SCR switch in series in the suggested structure. The fault current in the primary and the secondary winding of the reactor and the voltage of the superconductor on the secondary were measured and compared. The results showed that the fault current in the load line was the lowest and the voltage applied at both ends of the superconductor was also low when the secondary winding of the reactor had lower turn ratio than the primary. It was confirmed based on these results that the turn ratio of the secondary winding of the reactor must be designed to be lower than that of the primary winding to reduce the burden of the superconductor and to lower the fault current. Also, the suggested structure could increase the duration of the limited current by limiting the continuous current after the first half cycle from the fault with the fault current limiter.

Cryogenic cooling system for a 154 kV/ 2 kA superconducting fault current limiter

  • In, Sehwan;Hong, Yong-Ju;Yeom, Hankil;Ko, Junseok;Kim, Hyobong;Park, Seong-Je;Han, Young-Hee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.2
    • /
    • pp.34-39
    • /
    • 2018
  • A cryogenic cooling system is designed for a 154 kV/ 2 kA three-phase hybrid type superconducting fault current limiter (SFCL). The superconducting modules of the SFCL have the operating condition of 71 K at 500 kPa. The total heat load of the SFCL including the cooling system is estimated at 9.6 kW. The cooling system of the closed loop is configured to meet the operating condition, depending on cooling methods of forced flow cooling and re-liquefaction cooling. The cooling system is composed of three cryostats with superconducting modules, cryocoolers, liquid nitrogen circulation pumps, a subcooler and a pressure builder. The basic cooling concept is to circulate liquid nitrogen between three SFCL cryostats and the cryocooler, while maintaining the operating pressure. The design criterion for the cooling system is based on the operation results of the cooling system for a 154 kV/2 kA single-phase hybrid SFCL. The specifications of system components including the piping system are determined according to the design criterion.

Operation characteristics of SFCLs combined with a transformer in three-phase power system

  • Jung, B.I.;Choi, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.30-33
    • /
    • 2013
  • The studies of superconducting fault current limiter (SFCL) for reduction of the fault current are actively underway in the worldwide. In this paper, we analyzed the characteristics of a new type SFCL using the conventional transformer and superconducting elements combined mutually. The secondary and third windings of this SFCL were connected the load and the superconducting element, respectively. The electric power was provided to load connected to secondary windings of the transformer in normal state of power system. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the ripple phenomenon of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the CT(current transformer) and then turn-on and turn-off switching behavior of the SFCL was performed by the SCR(silicon-controlled rectifier). As a result, the proposed SFCL limited the fault current within a half-cycle efficiently. We confirmed that the fault current limitation rate was changed according to the winding ratio of a transformer.

Analysis of Transient Characteristics of SFCL using the Three-Phase Transformer and Power Switch (삼상 변압기와 전력용 스위치를 이용한 초전도 한류기의 과도특성 해석)

  • Jung, Byung-Ik;Choi, Hyo-Sang;Park, Jung-Il;Cho, Geum-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1743-1747
    • /
    • 2012
  • The research of superconducting fault current limiter (SFCL) for reduction of the fault current is actively underway in the worldwide. In this paper, we analyzed the characteristics of a SFCL using the transformer and superconducting elements combined mutually in accordance with the fault types. The structure of this SFCL was composed of the secondary and third windings of a transformer connected to the load and the superconducting element, respectively. The provided electric power flew into the load connected to the secondary winding of the transformer in normal state. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the effect of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the current transformer(CT) and then turn-on and turn-off switching behavior of the secondary line in the transformer was performed by the silicon-controlled rectifier(SCR). As a result, the proposed SFCL limited the fault current within one-cycle efficiently. Also, the degradation of the superconducting element in the normal state was avoided.

PID Controller and Derivative-feedback Gain Design of the Direct-drive Servo Valve Using the Root Locus and Manual Tuning (근궤적과 수동 조정에 의한 직접 구동형 서보밸브의 PID 제어기 및 미분피드백 이득 설계)

  • Lee, Seong Rae
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.15-23
    • /
    • 2016
  • The direct-drive servo valve(DDV) is a kind of one-stage valve because the main spool valve is directly driven by the dc motor. Since the DDV structure is simple, it is less expensive, more reliable, and offers a reduced internal leakage and a reduced sensitivity to fluid contamination. The control system of the DDV is highly nonlinear due to a current limiter, a voltage limiter, and the flow-force effect on the spool motion. The shape of the step response of the DDV-control system varies considerably according to the magnitudes of the step input and the load pressure. The system-design requirements mean that the overshoots should be less than 20%, and the errors at 0.02s should be less than 2%, regardless of the reference-step input sizes of 1V and 5V and the load-pressure magnitudes of 0MPa and 20.7MPa. To satisfy the system-design requirements, the PID-controller parameters of $K_c$, $T_i$ and $T_d$, and the derivative-feedback gain of $K_{der}$ are designed using the root locus and manual tuning.

Analysis on Current Limiting Characteristics of Series Connection-type SFCL with Two Magnetically Coupled Circuits Applied into a Simulated Power System (모의전력계통에 적용된 두 개의 자기결합 회로를 갖는 직렬연결형 초전도 전류제한기의 전류제한 특성 분석)

  • Ko, Seok-Cheol;Lee, Shin-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.1
    • /
    • pp.68-72
    • /
    • 2013
  • The series connection-type superconducting fault current limiter (SFCL) with two magnetically coupled circuits was suggested and its effectiveness through the analysis on the current limiting and recovery characteristics was described. The fault current limiting characteristics of the proposed SFCL as well as the load voltage sag compensating characteristics according to the winding direction were investigated. To confirm the fault current limiting and the voltage sag suppressing characteristics of the this SFCL, the short-circuit tests for the simulated power system with the series connection-type SFCL were carried out. The series connection-type SFCL designed with the additive polarity winding was shown to perform more effective fault current limiting and load voltage sag compensating operations through the fast quench occurrence right after the fault appears and the fast recovery operation after the fault removes than that with the subtractive polarity winding.

Feasibility Study of Superconducting Fault Current Limiter Application to Korean Power System

  • Kim, Hak-Man;Kim, Jong-Yul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.103-106
    • /
    • 2003
  • The short circuit current problem is one of the operational problems that need to be solved by power system engineers in Korea. It is an important issue in the Seoul metropolitan area especially because of highly meshed configuration. Currently, it is regulated by changing 154 kV system configuration from loop connection to radial system, by splitting of the bus where load balance can be achieved, and by upgrading circuit breaker rating. A development project for 154 kV/2 KA SFCL application to 154 kV transmission system after 2010 is proceeding. In this paper, a feasibility study of superconducting fault current limiter (SFCL) is carried out in Seoul metropolitan area to find out the effects of its application and feasibility. This study shows that it can reduce fault current considerably, and as it can minimize the upgrading of circuit breaker rating, the economic potential of SFCL is evaluated positively.

The Operational Characteristic of Modified DC Reactor Type HTSC Fault Current Limiter for Accident of Both Power Source Side and Load Side (전원단과 부하단사고에 따른 Modified DC 리액터 타입 고온초전도전류제한기 동작특성)

  • Lim, Sung-Hun;Lee, Jae;Kang, Hyeong-Gon;Choi, Hyo-Sang;Lee, Seong-Ryong;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.97-99
    • /
    • 2001
  • 본 논문은 전원단과 부하단사이에 GTO 사이리스터 브리지가 설치된 단상 DC 리액터타입을 적용한 고온초전도 사고전류제한기 동작특성에 대해 분석하였다. GTO 사이리스터 브리지가 설치된 DC 리액터 타입 FCL(FAULT CURRENT LIMITER)은 평상시에 초전도코일에 전기에너지를 저장한다. 전원단의 사고로 인해 전력공급이 중단되었을 경우 FCL은 부하에 저장된 에너지를 공급할 수 있을 뿐 아니라 부하단 사고로 인한 사고전류 제한기능을 수행하게 되는데 이와 같은 동작은 GTO 사이리스터를 제어함으로서 가능해진다.

  • PDF

Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices (고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.