• 제목/요약/키워드: Load flow analysis

검색결과 876건 처리시간 0.033초

AC/DC 계통의 전압안정도 해석 (Voltage Stability Analysis of AC/DC Systems)

  • 남해곤;김용학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.89-91
    • /
    • 1995
  • This paper describes an extension or a pair or multiple load flow solutions and nose curve method developed for voltage stability analysis or AC power systems to AC/DC systems. In this approach the converters are regarded as voltage dependent loads. Assuming that the converters at the unstable (-mode) solution consume the same power equal to the power at the stable (+mode) solution, the unstable solutions or the nose curves arc determined. This method is very efficient since estimating voltage collapse point and voltage stability margin arc determined by a few iterations of multiple load flow solutions. Also the method has the advantages that since the structure or Jacobian matrix is same with that of AC load flow, modal analysis or voltage stability is readily applicable if desired.

  • PDF

우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정 (Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed)

  • 김경태;정은성;김상욱;이길성;성진영
    • 한국물환경학회지
    • /
    • 제25권6호
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.

Web과 DB를 연동한 조류계산 시스템 개발 (Development of Load Flow Analysis System based Web and DB)

  • 최익순;김건중;최장흠;한현규;오성균;이병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.17-19
    • /
    • 2000
  • This paper deals with Load Flow Program for client/server system. Clients play roles of input and output of the data. The client upload input-data file to the server which takes the part of the function of solving the Load Flow. The developed LF COM(Component Object Model) carry out solving the Load Flow and saving the result and the input data to DataBase. It proved the developed System to be compatible through the Case Study.

  • PDF

송전제약하에서 DC LOAD FLOW를 이용한 한계비용의 분석과 계통의 분할에 관한 연구 (A Study on the analysis of marginal cost using DC load flow in transmission constraint and network partition)

  • 장시진;정해성;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.373-375
    • /
    • 2000
  • By DC load flow approximation, we analyzed marginal cost that is the important factor of price signal for network congestion management and expressed as a function of load. In network congestion, a large scale electric network is partitioned into subnetwork to provide a effetive price signal through zonal pricing. We propose a new network partition technique using marginal cost sensitivity with a variety of load consumption.

  • PDF

IPLAN을 이용한 UPFC 조류계산 모형 (UPFC model for power flow using IPLAN)

  • 국경수;김학만;전진홍;오태규;장병훈;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.316-318
    • /
    • 1998
  • This paper presents an approach that provides an equivalent initial operating condition of UPFC in load-flow study for stability analysis. The UPFC model for load-flow implemented by IPLAN in PSS/E is represented by an equivalent load injection. In doing so, the transmission line to which UPFC is connected is disconnected and the function of UPFC is represented by the equivalent load variation. This operating condition may not be adequate as an initial condition for subsequent dynamic simulation. The proposed approach provides a way of equivalencing UPFC load injection without line disconnection. The method was applied to a realistic power system for validity.

  • PDF

Flow Divider Valve의 최적설계를 위한 동특성 해석 (Dynamic Characteristics Analysis for Optimal Design of Flow Divider Valve)

  • 황태영;박태조
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.123-130
    • /
    • 1999
  • Flow divider valve는 한 개의 공급라인에서 두 개 이상의 출력라인으로 유압유를 일정비율로 분배하는 유압제어밸브로서 하중압력이나 공급압력 등에 관계없이 항상 일정비율의 유량분배가 가능해야 한다. 현재 상용제품의 유량분할 정확도는 90~95% 수준이며, 이러한 유량분할오차(Flow dividing error)는 유압시스템에 누적오차로 작용하여 많은 문제점을 야기시키고 있어 보다 고정밀 유량제어가 가능한 Flow divider valve 개발이 요구된다. 본 연구에서는 외력을 고려한 스푸울의 거동을 수치적으로 정확하게 조사하여 Flow divider valve의 동특성을 규명함과 동시에 유량분할 오차를 감소시키는 최적설계방안을 제시하고자 한다. 동특성 해석은 일정한 하중저항을 입력신호로 작용하는 경우에 대해서 제시하였으며, 이때의 고정오리피스와 가변오리피스의 단면적 및 스푸울의 단면적 변화에 따른 동특성의 변화를 조사하였다.

  • PDF

베어링레이스의 온간성형에서 UBET 해석에 의한 공정개선 및 유동구속조건의 향상 (The Improvement of Bearing-Race Forming Process Using UBET Analysis)

  • 김영호;배원병;박재우
    • 한국정밀공학회지
    • /
    • 제14권8호
    • /
    • pp.92-100
    • /
    • 1997
  • An upper-bound elemental technique (UBET) analysis is carried out to improve the material flow and to reduce the load of bearing-race forming process. The UBET analysis, which adapts the advantages of stream function and finite element method, is useful for predicting the profile of complex geometric bound- ary. From the UBET analysis, the forming load, the velocity distribution and the stream line of the deformed billet are determined by minimizing the total power consumption with respect to chosen parameters. The results of present UBET analysis are better than those of previous UBET analysis. Experiments have been carried out with model material plasticine billets at room temperature. The theoretical predictions for forming load and flow pattern(stream line) are in good agreement with the experimental results.

  • PDF

Jacobian 행렬의 비 대각 요소를 보존시킬 수 있는 조류계산에 관한 연구 (A Study on the load Flow Calculation for preserving off Diagonal Element in Jacobian Matrix)

  • 이종기;최병곤;박정도;류헌수;문영현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권9호
    • /
    • pp.1081-1087
    • /
    • 1999
  • Load Flow calulation methods can usually be divided into Gauss-Seidel method, Newton-Raphson method and decoupled method. Load flow calculation is a basic on-line or off-line process for power system planning. operation, control and state analysis. These days Newton-Raphson method is mainly used since it shows remarkable convergence characteristics. It, however, needs considerable calculation time in construction and calculation of inverse Jacobian matrix. In addition to that, Newton-Raphson method tends to fail to converge when system loading is heavy and system has a large R/X ratio. In this paper, matrix equation is used to make algebraic expression and then to slove load flow equation and to modify above defects. And it preserve P-Q bus part of Jacobian matrix to shorten computing time. Application of mentioned algorithm to 14 bus, 39 bus, 118 bus systems led to identical results and the same numbers of iteration obtained by Newton-Raphson method. The effect of computing time reduction showed about 28% , 30% , at each case of 39 bus, 118 bus system.

  • PDF

한국형 EMS 시스템용 실시간 조류계산 프로그램 개발 (Development of Real-Time Load Flow Program for Korean Energy Management System)

  • 윤상윤;조윤성
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.242-247
    • /
    • 2010
  • This paper introduces a real-time load flow program for Korean energy management system(EMS). This study is concentrated on the following aspects. First, we propose the model of the real-time database and power system equipment for the real-time load flow. These models are extracted from the needs of load flow functions and are designed to the application common information. Second, several techniques are applied for the efficient convergence and computational speed. The generation/load mismatch is redistributed using generator participation factors which are separated to the reference bus. For the voltage control, the jacobian matrix is composed with the basic Y matrix elements and the voltage control elements. Through the optimally ordering, jacobian row and column for a column is changed. However all jacobian matrix entries have same order with the Y matrix. The proposed program is tested using the Korea Electric Power Corporation(KEPCO) system. Through the test, we verified that the proposed program can be effectively used to accomplish the Korean EMS system.

수질오염총량관리 단위유역 유량측정자료를 이용한 유황곡선 작성 (Development of a Flow Duration Curve with Unit Watershed Flow Data for the Management of Total Maximum Daily Loads)

  • 박준대;오승영;최윤호
    • 한국물환경학회지
    • /
    • 제28권2호
    • /
    • pp.224-231
    • /
    • 2012
  • It is necessary to develop flow duration curve (FDC) on each unit watershed in order to analyze flow conditions in the stream for the management of Total Maximum Daily Loads (TMDLs). This study investigated a simple method to develop FDC for the general use of the curve. A simple equation for daily flow estimation was derived from the regression analysis between the 8-day interval flow data of a unit watershed and the daily flow monitoring data of an adjacent upstream region. FDC can be prepared with the calculation of daily flow by the equation for each unit watershed. An annual and a full-period FDC were drawn for each unit watershed in Guem river basin. Standard flow such as low and ordinary flow can be obtained from the annual FDC. Major percentile of flow such as 10, 25, 50, 75 or 90% can be obtained from the full-period FDC. It is considered that this simple method of developing FDC can be utilized more widely for the calculation of standard flow and the assessment of water quality in the process of TMDLs.