• Title/Summary/Keyword: Load flow

Search Result 2,380, Processing Time 0.026 seconds

A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions (흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구)

  • 박찬우;조현철;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

Development of Alternative Algorithms to the Decoupled Load Flow (Decoupled Load Flow 알고리즘의 유연한 대안 알고리즘들의 개발에 관한 연구)

  • Lee, S.C.;Park, Sang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.248-250
    • /
    • 1999
  • 본 논문에서 제안된 조류계산 알고리즘은 Jacobian의 off-diagonal 부 행렬을 완전히 무시하는 Decoupled Load Flow(DCL) 알고리즘들의 유연한 대안으로 반복(iteration)당 최소한의 추가 계산 부담으로 Jacobian의 off-diagonal 부분의 효과를 부분적으로 반영함에 의해 수렴 특성을 향상시킬 수 있다. 제안된 방법들은 특히 Fast Decoupled Load Flow(FDL)로 대표되는 DCL들의 수렴특성이 불안정해질 경우, 효과적으로 수렴특성을 향상시킬 수 있다. 제안된 알고리즘들은 Newton-Raphson Load Flow(NRL) 방법에서 Jacobian의 off-diagonal 부분의 효과를 점진적으로 제거하는 방법으로 유도하였고, 간략화 과정에서는 Neuman series expansion을 사용하였다. 실험결과 제안된 알고리즘들은 반복횟수와 전반적인 수렴 속도에서 확실한 성능향상을 보여주었다. 제안된 알고리즘들은 특히 DCL의 수렴성능이 문제가 있을 시 full NRL 대신에 적용할 수 있는 가능성이 있어 조류계산 시간을 단축해 줄 수 있을 것으로 기대된다.

  • PDF

Methodology for the Identification of Impaired Waters Using LDC for the Management of Total Maximum Daily Loads (오염부하지속곡선(LDC)을 이용한 수질오염총량관리 단위유역 목표수질 달성여부 평가방법)

  • Park, Jun Dae;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.693-703
    • /
    • 2012
  • Load Duration Curve(LDC) is a useful tool for analyzing water quality characteristics under various stream flow conditions. This study investigated the methods to identify impaired waterbodies in the assessment of water quality goal attainment by using LDC for the management of Total Maximum Daily Loads (TMDLs). Three methods were proposed. Non-typical regime exclusion method is a method to exclude water quality observations in the non-typical extreme flow conditions in order to minimize the influence of non-ordinary water quality. Flow regime weighted average method is a method to calculate weighted mean water quality instead of arithmetic mean in order to consider water characteristics properly on stream flow regime in addition to the effect of Non-typical regime exclusion method. Load exceeded interval comparison method is a method to compare the intervals between the attained and non-attained load duration periods on the LDC. The assessment of water quality goal attainment can be performed more reasonably and precisely considering water quality variations on stream flow conditions by applying these proposed methods.

Penalty Factor Computation Algorithms for Economic Load Dispatch Based on B-Coefficient and AC Load Flow and their Performance Comparison (경제급전을 위한 B-계수와 조류계산에 의한 페널티계수 산정법의 개발 및 성능비교)

  • Nam, H.K.;Moon, Y.H.;Choi, H.K.;NamKung, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.206-209
    • /
    • 1999
  • This paper presents an improved method of calculating the penalty factors for economic load dispatch based on B-coefficient and AC load flow and their performance comparison. The algorithm for calculating B-coefficients by Meyer is improved and its performance is compared with that of AC load flow. The B-coefficient method is superior to the load flow method in its simplicity and computation speed. However accuracy of the B-coefficient method is not satisfactory when it is applied to the ill-conditioned systems where generators produce excessive reactive power.

  • PDF

Application of peak load for industrial water treatment plant design (공업용수 정수장 설계시 첨두부하 적용방안)

  • Kim, Jinkeun;Lee, Heenam;Kim, Dooil;Koo, Jayong;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.225-231
    • /
    • 2016
  • Peak load rate(i.e., maximum daily flow/average daily flow) has not been considered for industrial water demand planning in Korea to date, while area unit method based on average daily flow has been applied to decide capacity of industrial water treatment plants(WTPs). Designers of industrial WTPs has assumed that peak load would not exist if operation rate of factories in industrial sites were close to 100%. However, peak load rates were calculated as 1.10~2.53 based on daily water flow from 2009 to 2014 for 9 industrial WTPs which have been operated more than 9 years(9-38 years). Furthermore, average operation rates of 9 industrial WTPs was less than 70% which means current area unit method has tendency to overestimate water demand. Therefore, it is not reasonable to consider peak load for the calculation of water demand under current area unit method application to prevent overestimation. However, for the precise future industrial water demand calculation more precise data gathering for average daily flow and consideration of peak load rate are recommended.

NAVIER-STOKES SIMULATION OF A VISCOUS MICRO PUMP WITH A SPIRAL CHANNEL (스파이럴 채널을 가진 초소형 점성 펌프의 Navier-Stokes 해석)

  • Seo, J.H.;Kang, D.J.
    • Journal of computational fluids engineering
    • /
    • v.16 no.1
    • /
    • pp.90-95
    • /
    • 2011
  • The Navier-Stokes equations are solved to study the flow characteristics of a micro viscous pump. The viscous micropump is consisted of a stationary disk with a spiral shaped channel and a rotating disk. A simple geometrical model for the tip clearance is proposed and validated by comparing computed flow rate with corresponding experimental data. Present numerical solutions show satisfactory agreement with the corresponding experimental data. The tip clearance effect is found to become significant as the rotational speed increases. As the pressure load increases, a reversed flow region is seen to form near the stationary disk. The height of the channel is shown to be optimized in terms of the flow rate for a given rotational speed and pressure load. The optimal height of the channel becomes small as the rotational speed decreases or the pressure load increases. The flow rate of the pump is found to be in proportion to the width of channel.

A Load Flow Based Approach to Transaction Cost Allocation in Transmission Network (조류계산에 기초한 탁송요금 계산)

  • Park, Young-Moon;Lim, Jung-Uk;Won, Jong-Ryul;Park, Jong-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1149-1152
    • /
    • 1997
  • This paper describes a novel approach for allocating transmission costs among users of transmission services. In the suggested approach, the cost share of each participant is proportional to amount of its line flow. To develop individual user's impact, the line utilization factors of each participant are derived by power flow equations of all nodes (i.e., load-flow equations). To deal With the slack bus problem inherent in the conventional load-flow analysis more practically, a additional power supply/demand balance equation is incorporated. Although the developed allocation rule is basically similar to the existing MW-mile method in the aspect of embedded cost allocation, it does not require to get load flow solutions of each wheeling transaction when multiple transmission transactions are considered.

  • PDF

Assessment of the Water Quality of Jungnang Stream by Flow Conditions Using Load Duration Curve (부하지속곡선을 이용한 중랑천의 유량 조건별 수질특성 평가)

  • Choi, Kyung-Wan;Shin, Kyung-Yong;Lee, Hyung-Jin;Jun, Sang-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.438-447
    • /
    • 2012
  • Objective: The objective of this study was to suggest a method through which load duration curve was used to assess the achievement of water quality targets in accordance with the criteria for pollutant load depending on flow rate variation. Methods: The stage-discharge curve and flow duration curve of Jungnang Stream were deduced. Using water quality targets and measurement of the stream, the flow duration curve was also drawn. Based on these, the feasibility of achievement of water quality targets in respect to flow rate was assessed. Results: In terms of the load duration curve of the stream, it was observed that excess of criteria for concentrations of $BOD_5$, $COD_{Mn}$ and SS frequently occurred. On the other hand, when the flow rate was low, the concentrations of T-N and T-P exceeded the criteria. Conclusions: Through the load duration curve, the overall water quality of Jungnang Stream was understood. When the flow rate is high, management of point source of $BOD_5$, $COD_{Mn}$ and SS is needed to achieve water quality targets for Jungnang Stream. On the other hand, when the flow rate is low, the management of non-point source T-N and T-P is necessary to attain the water quality goal.

The Optimal Power Flow Algorithm Considering Load Power Factor Limits (부하역률 제약조건을 고려한 최적 급전 알고리즘)

  • 김광욱;조종만;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.9
    • /
    • pp.494-499
    • /
    • 2004
  • This paper presents to compute the power economic dispatch, an optimal power flow (OPF) computation algorithm, considering the load power factor limits constraint in developed. Efficient reactive power planning enhances economic operation as well as system security. Accordingly, an adequate level of power factor limits for the load busesshould be evaluated for economic operation. In this paper, the ranges of acceptable load power factors are portrayed as bandwidths of load power factor expressed as a function of load level. The load power factor limits are included and described into the OPF's objective function. The method Proposed is applied to IEEE 26 bus system.

A Flow Visualization of ER Fluids in 3Port Rectangular Tube (3 포트 사각 튜브내에서 ER유체의 유동 가시화)

  • Jang Sung-Cheol;Yum Man-Oh;Jang Mun-Jey
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.2
    • /
    • pp.30-37
    • /
    • 2006
  • The purpose of this study is to visualize the characteristics of ER fluids as preceding step of developing 3 port ER valves. ER fluids are made with silicone oil and 3 weight fraction starch having hydrous particles. The flow visualization of ER fluids flow is obtained by CCD camera with changing the strength of electric field to ER fluids flow. As the strength of the electric field increases, more clusters in flow are made and these clusters are though to be the reasons of the load flow rate being increased and the outlet flow rate being decreased. The ER Valves and load and outlet flow rate check method are considered to be applied to the fluid power control system.