• 제목/요약/키워드: Load composition ratio

검색결과 55건 처리시간 0.029초

제한급전하는 오프그리드의 독립형 마이크로그리드 최적 설계 및 경제성 평가를 위한 일부하곡선 추정 방안에 관한 연구 (A Study on the Estimation Method of Daily Load Curve for the Optimization Design and Economic Evaluation of Stand-alone Microgrids Based on HOMER Simulation in Off-Grid Limiting the Supply of Electricity)

  • 남용현;윤석민;김정훈;황성욱
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.27-35
    • /
    • 2019
  • There is a growing interest in various microgrid solutions that supply electricity 24 hours a day to off-grid areas where are not connected with the main grid, and Korea has many positive effects by constructing overseas microgrids as a country operating the emission trading scheme. Since it is not clear how to obtain load curves that is one of the inputs of the HOMER used to design a microgrid optimization plan, or it is necessary to examine whether electricity is supplied to the peak load level of the areas where have not received the electricity benefits from the viewpoint of the demand management, a methodology should be developed to know the load composition ratio and the shape of the daily load curve. In this paper, the relative coefficient and average load information for each load group obtained from the survey are used besides peak load and total average load. A mathematical model is proposed to derive the load composition ratio in the form of a Quadratic Programming and the load forecasting is performed using simple linear regression with future indicators. The effectiveness of the proposed method is confirmed for the Philippine island region supported by Korea Energy Agency and the Asian Development Bank.

A Dynamic QoS Adjustment Enabled and Load-balancing-aware Service Composition Method for Multiple Requests

  • Wu, Xiaozhu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권3호
    • /
    • pp.891-910
    • /
    • 2021
  • Previous QoS-aware service composition methods mainly focus on how to generate composite service with the optimal QoS efficiently for a single request. However, in the real application scenarios, there are multiple service requests and multiple service providers. It is more important to compose services with suboptimal QoS and maintain the load balance between services. To solve this problem, in this paper, we propose a service composition method, named as dynamically change and balancing composition method (DCBC). It assumes that the QoS of service is not static, and the services can adjust the value of QoS to gain more opportunities to be selected for composition. The method mainly includes two steps, which are the preprocessing step and the service selection step. In the preprocessing step, a backward global best QoS calculation is performed which regarding the static and dynamic QoS respectively; then guided by the global QoS, the feasible services can be selected efficiently in the service selection step. The experiments show that the DCBC method can not only improve the overall quality of composite services but also guarantee the fulfill ratio of requests and the load balance of services.

압전특성 및 부하변화에 따른 압전트랜스포머의 전기적 특성 (Electrical Characteristics of the Piezoelectric Transformer as a Function of Piezoelectric Properties and Load Variations)

  • 민석규;윤광희;류주현
    • 한국전기전자재료학회논문지
    • /
    • 제14권4호
    • /
    • pp.289-296
    • /
    • 2001
  • The piezoelectric transformers of 2.0x10x48 ㎣ size were fabricated with PSN-PMN-PZT(T10 and PNW-PMN-PZT(T2) composition ceramics. Effects of micro structural and piezoelectric properties on the electrical characteristics of the piezoelectric transformers were investigated. Under the fixed output power of 6 W, temperature rise of T1 transformer at the optimum load was smaller than T2 one because of fine grain size effect. Voltage step-up ratio of T1 transformer showed higher value than T2 one T1 transformer showed an excellent properties with voltage step-up ratio of 12.41, efficiency of 95.23% and temperature rise of 7.2$^{\circ}C$ at 200㏀ load resistance. And also, T2 transformer showed an excellent properties with voltage step up ratio of 9.81, efficiency of 95.51% and temperature rise of 9$^{\circ}C$ at 150㏀ load resistance.

  • PDF

디스크형 압전변압기의 전극비에 따른 전기적 특성 (A Electrical Characteristics of Disk-type Piezotransformer with Electrode Ratio of Driving and Generating Part)

  • 이종필;채홍인;정수현;홍진웅
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.458-463
    • /
    • 2003
  • In order to develope piezoelectric transformer for the ballast of fluorescent lamp, a new shape and electrode pattern of piezoelectric transformer has been investigated in this work. The composition of piezoelectric ceramics was 0.95Pb(Zr$_{0.51}$Ti$_{0.49}$)O$_3$+0.03Pb(Mn$_{1}$3/Nb$_{2}$3/)O$_3$+0.02Pb(Sb$_{1}$2/Nb$_{1}$2/)O$_3$. The sample prepared by this composition system showed the characteristics which has about 1200 of relative dielecric constant, 1100 of the mechanical quality factor, 0.53 of the electromechanical coupling coefficient, 320 pC/N of the piezoelectric constant d$_{33}$, 0.3 % of the dissipation factor. Diameter and thickness of disk-type piezoelectric transformer was 45 mm and 4 mm, respectively. The driving and generating electrode with their gap of 1mm were fabricated on the top surface. But the common electrode was fabricated on the whole bottom surface. The electrode surface ratio of driving and generating part on the top surface ranges from 1.4:1 to 3:1. We investigated the electrical characteristics with the variation of the electrode surface ratio of driving and generating part in the range of load resistance of 100 $\Omega$~70 k$\Omega$. The set-up voltage ratio of this piezoelectric transformer increases with increasing both the electrode surface of driving part and the load resistance. The set-up voltage ratio at no load resistance was more than 60 times. On the other hand, the efficiency decreases with increasing the electrode surface of driving part. In the case of the electrode surface of both 1.4:1 and 2:1, maximum efficiency showed above 97 % at load resistance of 2 k$\Omega$. However, in the case of the electrode surface of 3:1, maximum efficiency showed about 94 % at load resistance of 3 k$\Omega$.>.>.>.

PTFE-폴리이미드 복합 재료의 마찰과 마모에 대한 성분비와 온도의 영향 (Effects of Composition Ratio and Temperature on Friction and Wear of PTFE-Polyimide Composites)

  • 심현해;권오관;이규한;김병환
    • Tribology and Lubricants
    • /
    • 제12권3호
    • /
    • pp.55-62
    • /
    • 1996
  • Present study was undertaken to investigate the effects of composition ratio and temperature on the friction and wear of PTFE-polyimide composites under the atmosphere of nitrogen gas. The load range was 0.62-3.46 MPa, and the temperature range was room temperature and 200$^{\circ}$C. To mention some of the notable results, friction coefficient of PTFE 100% varied relatively little within the given load and temperature ranges. Polyimide 100% showed the lowest friction coefficient of 0.06 at 200$^{\circ}$C among all the experiments. PTFE 80%-polyimide 20% showed the lowest wear factors on the whole. Friction coefficient of PTFE 20%-polyimide 80% varied from the highest 0.35 to the lowest 0.09 among all the materials at room temperature, and showed almost the same lowest values with polyimide 100% at 200$^{\circ}$C. Suggestion of friction and wear mechanisms of the materials was tried to explain the observed phenomena including above mentioned results.

농촌유역 유량-유달율 단순회귀식을 이용한 주암호 상류유역의 유달율 추정가능성 평가 (Evaluation of Flow-Pollutant Load Delivery Ratio Equations on Main Subwatersheds within Juam Lake)

  • 정재운;임병진;최동호;최유진;이경숙;김영주;김갑순;장남익;윤광식
    • 한국환경과학회지
    • /
    • 제21권10호
    • /
    • pp.1235-1244
    • /
    • 2012
  • The objective of this study is to evaluate Flow-Pollutant load delivery ratio equations developed from rural watershed on main subwatersheds within Juam Lake. Two regression equations for BOD and three equations for T-P were evaluated on Bosung cheon, Dongbok cheon, Songgwang cheon, Naenam cheon, and Sinpyeon cheon. The results show that estimation of BOD delivery ratio using flow-delivery equation is reliable when relative composition of discharge load of pollutant sources of a watershed is similar to those of watershed where the equation developed. On the other hand, application of regression equation for T-P was feasible when the landuse pattern and relative composition of discharge load of pollutant sources of a watershed is similar to those of watershed where the equation developed.

발전용 가스엔진의 개발 및 연소특성에 관한 연구 (A Study on the Development and the Combustion Characteristics of a Stationary Gas Engine)

  • 김현규;우석근;전충환;장영준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권6호
    • /
    • pp.128-139
    • /
    • 2000
  • Environmental concerns and shortage of petroleum have promoted considerable interest in the use of alternate fuels in stationary diesel engine. In this study, a heavy-duty, intercooler-turbocharged 6-cylinder stationary diesel engine was converted into stationary gas engine fueled with propane or natural gas for the cogeneration plants. One of the most important factors in the combustion features of a stationary gas engine is the fuel composition and operating parameters in terms of compression ratio, spark advance, and engine loads. Experiments with different fuel gas and load conditions were carried out with combustion pressure analysis and NOx measurement. Combustion analysis based on P-$\theta$ diagrams was also investigated by means of combustion duration and cycle variation. Compression ratio is 10.0 and ignition timing is set by using the gasoline setting as a base line and advanced toward BTDC. The results show that fuel composition and spark advance have dominant effects on combustion and NOx characteristics at operating conditions.

  • PDF

지역난방 사용자 구성비에 따른 열소비 패턴 분석 (Heat Consumption Pattern Analysis by the Component Ratio of District Heating Users)

  • 이훈;이민경;김래현
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.211-225
    • /
    • 2013
  • 본 연구에서는 서로 다른 위도의 도시 유형별로 주택과 건물 구성비를 가진 3지역을 선정하여 대상 지역별로 2008년 1년간(1.1~12.31)의 실제 운전실적을 이용하여 지역난방 사용자의 일일 및 연간 열소비 패턴을 분석하고, 지역별 상호 차이점을 파악하기 위하여 주택과 건물의 열소비 패턴을 비교 분석하였다. 특히 본 연구에서는 실제 주택 및 건물 지역난방 사용자가 사용한 열소비 패턴을 매시간대별로 파악하고, 연결 열부하(난방면적 ${\times}$ 단위열부하 : 시설용량과 지역난방 배관망의 설계기준이 되는 열부하로 난방면적에 용도별 단위열부하를 곱하여 산출[Gcal/h])와의 관계를 분석하여 일일, 연간 및 최대 부하율 결과값을 도출함으로써 주택 및 건물 지역난방 사용자 비율에 따른 최적의 열원시설 용량산정이 가능케 하고 수요개발(해당 시설용량으로 열공급이 가능한 지역난방 사용자의 범위로 각 사용자기계실의 연결열부하 합과 같음.)단계에서의 정확한 방향을 제시할 수 있는 근거를 도출하였다.

유리섬유/알루미늄 혼성 적층판의 인장특성과 파괴인성 평가 (Evaluation on Tensile Properties and Fracture Toughness of Glass Fiber/Aluminum Hybrid Laminates)

  • 우성충;최낙삼
    • 대한기계학회논문집A
    • /
    • 제29권6호
    • /
    • pp.876-888
    • /
    • 2005
  • Tensile properties and fracture toughness of monolithic aluminum, fiber reinforced plastics and glass fiber/aluminum hybrid laminates under tensile loads have been investigated using plain coupon and single-edge-notched specimens. Elastic modulus and ultimate tensile strength of GFMLs showed different characteristic behaviors according to the Al kind, fiber orientation and composition ratio. Fracture, toughness of A-GFML-UD which was determined by the evaluation of $K_{IC}$ and $G_{IC}$ based on critical load was similar to that of GFRP-UD and was much higher than monolithic Al. Therefore, A-GFML-UD presented superior fracture toughness as well as prominent damage tolerance in comparison to its constituent Al. By separating Al sheet from GFMLs after the test, optical microscope observation of fracture zone of GFRP layer in the vicinity of crack tip revealed that crack advance of GFMLs depended on the orientation of fiber layer as well as Al/fiber composition ratio.

대체혼합냉매를 사용하는 Lorentz-Meutzner의 이중 증발기 냉동 시스템의 성능에 관한 연구 (A Study of Lorentz-Meutzner's Two Evaporator Refrigeration System Using Alternative Refrigerant Mixtures)

  • 박영무
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.123-136
    • /
    • 1992
  • A preliminary thermodynamic design model of two-evaporator refrigerator/freezer system is constructed. This system is based on Lorentz-Meutzner cycle using refrigerant mixtures. This model screens alternative refrigerant (R32, R125, R143a, R22, R134a, R152a, R124, R142b, R123) mixtures to select the best performance-giving refrigerant mixtures and its composition for the system. Also, it estimates the effects of cooling temperatures of intercoolers, evaporator's area ratio, cooling load ratio on the performance of the system. The COP of the system ranges from 1.4 to 1.6, which is superior to that of the single evaporator system charged with R12 by 13% to 29%. Among 15 mixtures, R22/R123, R143a/R123, R32/R142b, and R32/R124 (in the order of high COP) are most recommendable. For the case of R22/R123, R22 mass fraction more than 0.5(Load Ratio=1.0) or 0.7(Load Ratio=0.33) is recomended in order to replace R12 without reduction in volumetric capacity when keeping the compressor as the same one. COP has the highest value with X(R22)=0.7 and 0.8, respectively. For the case of R143a/R123, in the similar manner, mass fraction of R143a is more than 0.5 or 0.6 while best performance occurs at X(R143a)=0.8. Higher temperature intercooler is more important for the performance of the system than lower temperature intercooler. The area ratio of evaporators is roughly proportional to load ratio of the evaporators.

  • PDF