• 제목/요약/키워드: Load compensator

검색결과 246건 처리시간 0.025초

A Voltage and Frequency Controller for Stand Alone Pico Hydro Generation

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.267-274
    • /
    • 2009
  • This paper deals with a voltage and frequency (VF) controller for an isolated power generation system based on an asynchronous generator (AG) driven by a pico hydro turbine. The proposed controller is a combination of a static compensator (STATCOM) and an electronic load controller (ELC) for decoupled control of the reactive and active powers of the AG system to control the voltage and frequency respectively. The proposed generating system along with its VF controller is modeled in MATLAB using SIMULINK and PSB (Power System Block Sets) toolboxes. The performance of the controller is verified for the proposed system and feeding various types of consumer load such as linear/non-linear, balanced/unbalanced and dynamic loads.

Average Current Control for Parallel Connected Converters

  • Jassim, Bassim M.H.;Zahawi, Bashar;Atkinson, David J.
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1153-1161
    • /
    • 2019
  • A current sharing controller is proposed in this paper for parallel-connected converters. The proposed controller is based on the calculation of the magnitudes of system current space vectors. Good current distribution between parallel converters is achieved with only one Proportional-Integral (PI) compensator. The proposed controller is analyzed and the circulating current impedance is derived for paralleled systems. The performance of the new control strategy is experimentally verified using two parallel connected converters employing Space Vector Pulse Width Modulation (SVPWM) feeding a passive RL load and a 2.2 kW three-phase induction motor load. The obtained test results show a reduction in the current imbalance ratio between the converters in the experimental setup from 53.9% to only 0.2% with the induction motor load.

A minimum energy control of a load-sensing hydraulic servo system

  • Kim, S.D.;Cho, H.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집(한일합동학술편); 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.747-752
    • /
    • 1987
  • The dynamic characteristics of a load-sensing hydraulic servo system are complex and highly unstable. Another property of the system is that the setting value of pump compensator is closely related to energy efficiency as well as control performance of the system. This necessitates the development of an effective control algorithm which guarantees good control performance, stability and energy efficiency. This paper considers a suboptimal PID control for the velocity control problem of the load-sensing hydraulic servo system. The results of simulations studies and experiments show that the proposed suboptimal controller can produce much better control performance than nonoptimal controllers and give effective energy efficiency.

  • PDF

첨단 AI 기법을 이용한 전력 변환기의 고성능 제어기 개발 (A Development of Intelligent Robust Precision Control System for Power Conversion System using AI)

  • 고종선;이용재;김규겸;한후석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.92-95
    • /
    • 2001
  • This study presents neural load disturbance observer that used to deadbeat load torque observer and regulation of the compensation gain by parameter estimator. As a result, the response of PMSM fellows that of the nominal plant. The load torque compensation method is compose of a neural deadbeat observer. To reduce of the noise effect, the post-filter, which is implemented by MA process, is proposed. The parameter compensator with RLSM(recursive least square method) parameter estimator is suggested to increase the performance of the load torque observer and main controller. The proposed estimator is combined with a high performance neural torque observer to resolve the problems. As a result, the proposed control system becomes a robust and precise system against the load torque and the parameter variation. A stability and usefulness, through the verified computer simulation, are shown in this paper.

  • PDF

STATCOM의 전압안정도개선 및 역률 보상 특성분석 (Characteristic Analysis of Voltage Stability Improvement and Power Factor Correction by STATCOM)

  • 박지용;박덕희;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권12호
    • /
    • pp.1507-1513
    • /
    • 1999
  • This paper describes simulation and experimental results to analyze the dynamic characteristics of STATCOM, which is connected to the ac system for compensation the power factor and improving the voltage stability. The simulation and experimental results confirm that the scaled model for STATCOM can properly compesate the power factor of the load and regulate the bus voltage at the common connection point.

  • PDF

시간지연을 갖는 프로세서의 견실한 2자유도 제어기 (Robust 2 D.O.F. Controller for the Precesses with dead-time)

  • 최주용;배종일;이만형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.319-319
    • /
    • 2000
  • In this paper, A dead-time compensator (DTC) for the processes with long dead-time is proposed. The processes which consist of dead-time, time-constant, gain are estimated by the linear least squares method in the frequency domain. A Smith predictor(SP) modified by including a filter becomes a two degree of freedom DTC. So the proposed DTC can yield the desirable setpoint and load disturbance responses separately. PI controller is used for the primary controller and the filter is tuned to be robust. Simulation examples demonstrate the properties of the proposed DTC.

  • PDF

유도전동기의 강인 속도 제어기에 관한 연구 (A Study on the Robust Speed Controller of Induction Motor)

  • 변황우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.612-615
    • /
    • 1997
  • In this paper, a robust speed controller considering the effect of uncertainty (plant parameter variation. external load disturbance. unmodeled and nonlinear dynamics etc..) for induction motor is proposed. Firstly. the dynamic model at nominal case of induction motor is estimated. Based on the estimated model. the IPSC ( Integral - Proportional Speed Controller) is designed. Then a DTRC (Dead-time Robust Controller) combining DTC ( Dead-time Compensator) & SRC (Simple Robust Controller) is designed to reduce the effects of parameter variation and external disturbance. Some simulated results are provided to demonstrate the effectiveness of the proposed controller.

  • PDF

부하불평형 해소를 위한 축소형 보상설비 개발 (Development of the down-scaled compensator for the solution of unbalanced load)

  • 김주락;한문섭;이장무;정호성;박현준;강문호;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.649-654
    • /
    • 2005
  • This paper proposes analysis on new equipment for power quality in electric railway. The proposed equipment consists of series inverter and parallel inverter. Each inverter is connected by capacitor as dc link. This structure can be compensated for active and reactive power in catenary through transformer.

  • PDF

외란관측기와 파라미터 보상기를 이용한 PMSM의 정밀속도제어 (Precision Speed Control of PMSM Using Disturbance Observer and Parameter Compensator)

  • 고종선;이택호;김칠환;이상설
    • 전력전자학회논문지
    • /
    • 제6권1호
    • /
    • pp.98-106
    • /
    • 2001
  • 본 논문에서는 영구자석 동기 전동기의 정밀 속도 제어의 방법으로 외란 관측기를 이용한 외란 보상방법과 파라미터 추정에 의해 보상기의 이득을 조절하도록 함으로서, 외란이 없는 등가 지표시스템의 응답 특성을 추정하도록 제안하였다. 외란 관측기에 의한 보상방법은 잘 알려진 데드비트 외란 관측기를 이용하였으며 잡음에 약한 데드비트 관측기의 단점을 보완하기 위하여 후단필터로서 MA처리를 통하여 잡음에 대한 영향을 줄이도록 하였다. 또한 관측기의 단점을 보완하기 위하여 후단필터로서 MA처리를 통하여 잡음에 대한 영향을 줄이도록 하였다. 또한 관측기의 파라미터와 실제 시스템의 파라미터의 차이로 발생하는 외란 추정 오차를 줄이고자 실제 시스템과 파라미터 보상기로 구성된 등가 시스템이 지표 시스템이 되도록 구성하였다. 시스템에 사용된 RLS파라미터 추정기는 외란에 의하여 편향된 추정 특성을 가진다. 이러한 파라미터 추정문제에 대하여 파라미터 추정기가 높은 성능을 갖는 데드비트 외란 관측기를 포함하도록 함으로서 외란에 의한 문제를 해결하였다. 이와 같이 제안된 제어기는 외란 및 파라미터 변화를 갖는 시스템에서 강인한 고정밀 제어를 할 수 있으며, 이의 안정성과 효용성을 컴퓨터를 이용한 모의 실험과 TMS320C31이 내장된 DS1102 DSP 보드를 이용하여 실험으로써 보였다.

  • PDF

Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations Part I : Analytical Study

  • Ahmed, Tarek;Noro, Osamu;Soshin, Koji;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권1호
    • /
    • pp.17-26
    • /
    • 2003
  • In this paper, the comparative steady-state operating performance analysis algorithms of the stand-alone single-phase self-excited induction generator (SEIG) is presented on the basis of the two nodal admittance approaches using the per-unit frequency in addition to a new state variable de-fined by the per-unit slip frequency. The main significant features of the proposed operating circuit analysis with the per-unit slip frequency as a state variable are that the fast effective solution could be achieved with the simple mathematical computation effort. The operating performance results in the simulation of the single-phase SEIG evaluated by using the per-unit slip frequency state variable are compared with those obtained by using the per-unit frequency state variable. The comparative operating performance results provide the close agreements between two steady-state analysis performance algorithms based on the electro-mechanical equivalent circuit of the single-phase SEIG. In addition to these, the single-phase static VAR compensator; SVC composed of the thyristor controlled reactor; TCR in parallel with the fixed excitation capacitor; FC and the thyristor switched capacitor; TSC is ap-plied to regulate the generated terminal voltage of the single-phase SEIG loaded by a variable inductive passive load. The fixed gain PI controller is employed to adjust the equivalent variable excitation capacitor capacitance of the single-phase SVC.