• Title/Summary/Keyword: Load cells

Search Result 455, Processing Time 0.022 seconds

Load Variation Removal and Stack Durability Experiments to Improve Lifetime of Fuel Cell Stack for Hydrogen Electric Vehicles (수소전기차 연료전지 수명 향상을 위한 부하 변동 제거 및 스택 내구성 실험)

  • DONGWON LEE;BEOMJUN KIM;SEOUNGRO LEE
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.4
    • /
    • pp.370-376
    • /
    • 2024
  • Load variations reduce the lifespan of polymer electrolyte fuel cells (PEFCs). To analyze the impact of load variations on durability of PEFCs, two stacks were built and operated continuously for 400 hours, one under load variations and the other under constant current condition with the same energy output. Using the example model provided by Mathworks, we obtained load variation data for the experiments. The performance curves were measured every 100 hours and analyzed by current interruption method and electrochemical impedance spectroscopy. The degradation comparison shows a much larger decrease in performance under the load variation. The activation resistance, electrical resistance, and mass transfer resistance are all found to increase more.

Field Measurements with the Construction of Cut and Cover Tunnel (복개 터널구조물의 현장 시공에 따른 계측 분석 사례)

  • 박시현;이석원;이규필;배규진;전오성;이종성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.149-156
    • /
    • 2002
  • Field measurements were carried out in this study to investigate the behavior of cut and cover tunnel such as the distribution and the magnitude of the earth pressure during back fill process of the ground material. Three kinds of measuring instruments, such as the earth pressure load cell, the concrete strain gauge and the reinforcing bar meter of embedded type in concrete structure were installed and measured. Earth pressure load cells, installed after construction of the tunnel lining, measure the outside forces acting on the tunnel lining with radial directions. Three load cells were installed at the crown, the right and the left shoulder of the tunnel, respectively. Three sets of reinforcing bar meter were installed in the double reinforcements of the tunnel lining and their locations were the same with the position of the earth pressure load cells. Concrete strain gauge was installed only one site of the upper compressive part at the tunnel crown. Based on the measuring results in the field, the deformation and the earth pressure acting on the tunnel lining were investigated with the back fill process of the ground material. Considerations on the validity of the measuring results were paid. For the analysis of measurements, after dividing back fill process into three steps, various factors which affect on the behavior of tunnel lining were investigated at each step.

  • PDF

Low-Voltage and High-Current DC Output Realized by Multiple Power Cells Based on Deadbeat and Automatic Current Sharing Control

  • Liu, Jinfeng;Zhang, Yu;Wang, Xudong;IU, Herbert Ho-Ching
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1575-1585
    • /
    • 2017
  • This paper presents a synchronous generator with a distributed system of multiple parallel three-phase power cells. This generator can immediately output high DC. Each power cell comprises three-phase windings and a three-phase synchronous rectification bridge with a deadbeat control of load power feedforward, which can improve the characteristics of dynamic response and reflect the load variance in real time. Furthermore, each power cell works well independently and modularly using the method of automatic maximum current sharing. The simulation and experimental results for the distributed controller of multiple power cells demonstrate that the deadbeat control method can respond quickly and optimize the quality of the energy. Meanwhile, automatic maximum current sharing can realize the validity of current sharing among power cells.

A SMA-based morphing flap: conceptual and advanced design

  • Ameduri, Salvatore;Concilio, Antonio;Pecora, Rosario
    • Smart Structures and Systems
    • /
    • v.16 no.3
    • /
    • pp.555-577
    • /
    • 2015
  • In the work at hand, the development of a morphing flap, actuated through shape memory alloy load bearing elements, is described. Moving from aerodynamic specifications, prescribing the morphed shape enhancing the aerodynamic efficiency of the flap, a suitable actuation architecture was identified, able to affect the curvature. Each rib of the flap was split into three elastic elements, namely "cells", connected each others in serial way and providing the bending stiffness to the structure. The edges of each cell are linked to SMA elements, whose contraction induces rotation onto the cell itself with an increase of the local curvature of the flap airfoil. The cells are made of two metallic plates crossing each others to form a characteristic "X" configuration; a good flexibility and an acceptable stress concentration level was obtained non connecting the plates onto the crossing zone. After identifying the main design parameters of the structure (i.e. plates relative angle, thickness and depth, SMA length, cross section and connections to the cell) an optimization was performed, with the scope of enhancing the achievable rotation of the cell, its ability in absorbing the external aerodynamic loads and, at the same time, containing the stress level and the weight. The conceptual scheme of the architecture was then reinterpreted in view of a practical realization of the prototype. Implementation issues (SMA - cells connection and cells relative rotation to compensate the impressed inflection assuring the SMA pre-load) were considered. Through a detailed FE model the prototype morphing performance were investigated in presence of the most severe load conditions.

Manufacture and Calibration of Load Cells under 2-direction Shears and Uniaxial Compression (2축 전단, 1축 압축 Load Cell의 제작과 Calibration)

  • Jung, Dong-Wook;Lee, Kyung-Bo;Lee, Han-Seon;Kim, Hee-Cheul;Lee, Young-Hak;Lee, Ki-Hak
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.27-28
    • /
    • 2009
  • In earthquake simulation tests of building structures, it is sometimes necessary to measure the shear forces in two orthogonal directions and axial force of a particular member. This study shows the manufacture and calibration of load cells for measuring 2-direction shears and uniaxial compression.

  • PDF

Intelligent Diagnosis System for an Electronic Weighting Machine (전자 저울을 위한 지능형 고장 진단 시스템)

  • 김종원;김영구;조현찬;서화일;김두영;이병수
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.11 no.9
    • /
    • pp.807-810
    • /
    • 2001
  • Election Weighting Machine is used an electronic scale which has many trouble because of broken load cells. In this paper, we propose an Intelligent Diagnosis System will for an electronic weighting machine using fuzzy logic. It s purpose be detect of the load cell s trouble. The electronic circuit of system, which call junction box , will be connected resistance in a series at circuit of Wheatstone Bridge for monitoring the condition of load cells.

  • PDF

Study on precision improvement in weight measurement of an egg for the automatic egg sorting system (계란(鷄卵) 자동(自動) 선별기(選別機)의 난중측정(卵重測定) 정밀도(精密度) 향상(向上)에 관(關)한 기초연구(基礎硏究))

  • Kim, K.D.;Bok, J.S.
    • Korean Journal of Agricultural Science
    • /
    • v.27 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • The various errors existing in a weight measurement system in most automatic egg sorting system available in Korean poultry farms have caused a large amount of economic losses to the egg producers. The object of this study was an importance of egg measurement system by changing both the number and the arrangements of load cells to reduce measuring errors. The results obtained were summarized as follow : 1. Four arrangements of load cells were selected as follows : layout I : Conventional one load cell method layout II : One load cell located as egg moving direction layout III : Two load cells located facing each other layout IV : Two load cells located as parallel with egg moving direction 2. The results of egg weight measurement according to four arrangements (Layout I, II, III, IV) showed that the average errors were 1.1218g, 0.5953g, 0.7786g, 0.2793g respectively. This indicated that the Layout IV (measuring by 2 load cells located parallel with the egg moving direction) caused the lowest average error and the best in precision. 3. The average vibration of axis X, y, Z were resulted as $5.1937{\times}10^{-3}G$, $9.3604{\times}10^{-3}G$, and $16.8657{\times}10^{-3}G$ respectively when sorting large sized egg. This indicated that the vibration of axis-Z was relatively higher than those of axis-X, and axis-Y.

  • PDF

Method for measuring 3-axis cutting force of a pick cutter using the single-axis load cell array (1축 로드셀 배열을 사용한 픽 커터의 3축 절삭력 측정방법)

  • Kang, Hoon;Jang, Jin-Seok;Park, Jin-Young;Cho, Jung-Woo;Jung, Myeong-Sik;Lee, Jae-Wook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.749-755
    • /
    • 2016
  • A new method for measuring the 3-axis cutting forces of a pick cutter by substituting costly 3-D load cells is proposed in this paper. The proposed cutting force measurement method is capable of estimating the 3-axis cutting forces through mechanical constraints using four single-axis compressive load cells and shoulder bolts. The feasibility of the proposed method was verified by finite element analysis, and the accuracy of the force measurement of the developed force measurement device was investigated by conducting linear rock cutting tests. The tests showed that the new cutting force measurement method is able to measure 3-axis cutting forces with a relative error of approximately 6%. These results imply that the new method could be a suitable alternative to conventional 3-D load cells. In addition, it will allow a significant reduction of approximately 20-30% in the costs required for measuring the cutting force when compared to conventional 3-D load cells.