• 제목/요약/키워드: Load Transient Response

검색결과 226건 처리시간 0.026초

345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발 (The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer)

  • 안용호;박종범;송택상;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

IGBT를 적용한 300kVA급 대용량 무정전전원장치 개발 (Development of the 300kVA Large Capacity IGBT UPS)

  • 변영복;김태진;조기연;박성준;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2057-2059
    • /
    • 1998
  • In order to maintain a high quality output voltage, conventional UPS systems use complex filters with large passive components. To overcome this drawback, real time feedback control schemes have been invested. However, these techniques require a high inverter switching frequency to dynamically adapt to changing load conditions reduce harmonics of the output voltage, thereby rendering the system inadequate for high power applications. This paper presents real time digital signal processor(DSP) control of a large capacity UPS system feeding nonlinear loads to provide a sinusoidal inverter output voltage, unity input power factor, low bus voltage ripple, and excellent transient response.

  • PDF

입력 능동 부스트 컨버터를 고려한 역률개선회로의 특성분석 (A study on the characteristics of power factor correction circuits with input active boost converter)

  • 장준영;이관용;김철진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.270-272
    • /
    • 2003
  • Switching power supplies are widely used in many industrial fields. Power factor correction(PFC) circuits have tendency to be applied in new power supply designs. The input active power factor correction(APFC) circuits can be implemented using either the two-stage approach or the single-stage approach. The single-stage PFC circuit has advantage to reduce the number of components by eliminating a need for the PFC switch and control circuit. However, unlike in the two-stage approach, the do voltage on the energy storage capacitor in a single-stage PFC circuit is not well regulated. As a result. in universal line application($90{\sim}265Vac$), the storage capacitor voltage varies with the load and line variation. In this paper, the performance of output voltage regulation and transient response are clarified here. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results of 2 [kW] prototype converter.

  • PDF

1.5V 60A급 VRM의 인덕터 손실 분석에 관한 연구 (A study on core loss analysis of 1.5V 60A class VRM)

  • 전현;이달우;안태영;최광보
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.449-451
    • /
    • 2005
  • In this paper, to report the experimental results the core losses of VRM inductor. The VRM, that has a output voltage 1.5V, output current 60A, maximum power of 90W. Experimental results verify, the VRM has a almost same data of fast transient response, a efficiency test with high flux and ferrite inductor. A maximum power conversion efficiency of the experimental VRM was measured at 92% within 0.2% load regulation.

  • PDF

연료전지 축전지 하이브리드 동력원의 접속 특성 분석 (Load Analysis of the FuelCell/Battery Hybrid Power System)

  • 이봉도;이원용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3081-3083
    • /
    • 2000
  • Fuel cell/battery hybrid power systems were studied to develop high efficient zero-emission fuel cell electric vehicles, Fuel cells were used as an auxiliary energy source and batteries were used as a transient power source. The fuel cell system is used to supply the average power demand. Dynamic response of the hybrid systems was simulated using PSPICE program and also tested experimentally, The results can be used to design the interface module and to determine the power requirement between the fuel cell unit and the battery pack.

  • PDF

외란 관측기와 Dead-Beat 제어기를 이용한 UPS 인버터 제어 알고리즘 (Inverter Control algorithm for UPS using Dead-Beat controller with disturbance Observer)

  • 장재영;송중호;최익;최주엽;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1196-1198
    • /
    • 2000
  • In this paper, a new approach for digital feedback control of PWM inverter is proposed, in which an output DB(Dead-Beat) control is achieved combined with a simple disturbance observer. The deadbeat controller, which is constructed multiple loop control scheme for PWM inverter, is used for fast transient response. The disturbance observer can make the disturbances be cancelled by adding feedforward compensating loop in controller. The simulation result show the proposed control scheme can achieved good voltage regulation against large load variations.

  • PDF

Wire Rope형 배관 지진$\cdot$진동완충기의 설계 (Design of the Wire Rope Type Snubber for Earthquake and Vibration of Piping System)

  • 김영중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.173-179
    • /
    • 1998
  • The piping system of a power plant suffers not only thermal expansion according to the temperature variation, but also many kinds of load: steady state vibrations due to the equipment operation or fluid flow, and transient vibrations due to the earthquake or explosion, etc. The snubbers are usually installed on the piping system to allow thermal expansion, and to reduce dynamic responses. Most snubbers are kinds of hydraulic and mechanical type, which can be degraded by leakage and abrasion, and required much cost for maintenance and replacement. Recently the wire rope type snubbers are developed and applied to the power plant, and proved as effective to reduce piping system vibration. Wire rope type snubber uses the bending rigidity and energy dissipation properties of ropes. This paper presents the procedure of design, and the method to apply hysteresis curve to the dynamic response analysis. Experiments were also conducted to confirm design results.

  • PDF

Adaptive Control for Speed of Wound Rotor Induction Motor With Slip Energy Recovery

  • Tunyasrirut, Satean;Kanchanatep, Attapol;Ngamwiwit, Jongkol;Furuya, Tadayoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.419-422
    • /
    • 1998
  • This paper presents how to design speed control of wound rotor induction motors with slip energy recovery. The speed is limited at some range of sub-synchronous speed of the rotating magnetic field. The problem with speed control by adjusting resistance value in the rotor circuit reduces the efficiency of power, because of the slip energy is lost when it passes through the rotor resistance. The control system is designed to maintain efficiency of motor, where it recovers loss energy by returning it to the system to improve the efficiency. A new PI control method of adaptive control [1],[13]is applied for the system with cascade type PI controller on the main loop to keep the speed constant and the internal loop to adjust the rotor appropriated current of the load provides the good transient response without overshoot.

  • PDF

PSCAD/EMTDC를 이용한 전력선통신 채널모델링 및 시뮬레이션에 관한 연구 (A Study of Channel Modeling and Simulation for Power Line Communication Systems using PSCAD/EMTDC)

  • 이종주;차재상;신명철
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권6호
    • /
    • pp.279-285
    • /
    • 2006
  • Power line communication channels are very complicated and models for communication channels vary with the types of electrical equipment, devices and load fluctuations. So, modeling and analysis of power line channels for implementation of power line communication systems is a very important process. Power line channel modeling and simulation are performed based on power system transient simulation models and power system CAD tools to create precise and accurate models. In this paper, a channel modeling and simulation method is proposed for power line communication systems using PSCAD/EMTDC, in which a PN 63 sequence code generator is applied for impulse response of the power line channel in the simulation model.

Over Current Protection Schemes for Active Filters with Series Compensators

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.134-145
    • /
    • 2004
  • This paper presents and analyses protection schemes for a series active compensator, which consists of a Unified Power Quality Conditioner (UPQC) or a hybrid active power filter. The proposed series active compensator operates as a high impedance "k(D)" for the fundamental components of the power frequency during over current conditions in the distribution system. Two control strategies are proposed in this paper. The first strategy detects the fundamental source current using the p-q theory. The second strategy detects the fundamental component of the load current in the Synchronous Reference Frame (SRF). When over currents occur in the power distribution system momentarily, the proposed schemes protect the series active compensator without the need for additional protection circuits, and achieves excellent transient response. The validity of the proposed protection schemes is investigated through simulation and compared with experimental results using a hybrid active power filter systems.