• 제목/요약/키워드: Load Shedding

검색결과 166건 처리시간 0.036초

주파수 변화율을 이용한 동적부하차단 방안 (A Scheme on the Dynamic Load Shedding Using Rate of Frequency Decline)

  • 이소영;장병태;이재욱;오화진;조범섭;김재현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.301-306
    • /
    • 2003
  • When a bulk power system experiences a serious disturbance or heavy load trip, the system frequency may drop and even collapse if the total generating power does not supply the system demand sufficiently. Since an isolated power system possesses a lower inertia and comes with limited reserves, the load shedding by under frequency relay becomes an important strategy to keep system natural frequency. This paper presents a scheme to determine the load shedding criteria by using the rate of change of frequency when the large disturbance happens.

지역별 직접부하제어 잠재량을 고려한 부하차단 확보량 결정에 관한 연구 (A Study on the Determination of Minimum Local Load Shedding Considering the Regional DLC Potentials)

  • 심건보;김정훈;황성욱;이창호;조인승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.407-409
    • /
    • 2002
  • This paper proposes a process using the load shedding scenario method that determines the minimum local load shedding quantity considering the local DLC(Direct Load Control) potentials. So this method is applied to Kyung-In area and determined the load shedding of this area with comparison to its DLC potentials.

  • PDF

A New Traffic Load Shedding Scheme in Microcellular CDMA with Uniform and Non-uniform Traffic Load

  • Park, Woo-Goo;Rhee, Ja-Gan;Lee, Hu;Lee, Sang-Ho
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권5호
    • /
    • pp.33-39
    • /
    • 1997
  • In this paper we proposed a new traffic load shedding scheme which maximizes the throughput of traffic control by decreasing the load of the hot-spot cell using minimum load cell selection (MLCS) algorithm and deployed control flow of calls to define characteristic for hadoff region. we compared the performance of the random shedding approach with that of the proposed algorithm. The results of simulation show that MLCS algorithm minimizes the cal blocking rate under a high-density traffic compared to the random shedding scheme.

  • PDF

유도전동기 부하 고려 시 저전압 부하차단을 이용한 전력계통 안정도 향상 방안 (Using the Under Voltage Load Shedding for Stability Enhancement of Power Systems Considering Induction Motor Load)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제65권1호
    • /
    • pp.1-6
    • /
    • 2016
  • Recently, proportion of the induction motor load is gradually increased. When a contingency in the power systems, it has been discovered phenomenon that the voltage is delayed recover caused mechanical characteristics of the induction motor load. It can be a serious impact on the voltage stability of the power system considering induction motor load. The scheme to mitigate this phenomenon tripping off the motors to prevent voltage drop and delayed voltage recovery on the load demand side. Fault induced delayed voltage recovery phenomenon is caused by stalling of small induction motor load in transmission level contingencies. In this paper, fault induced delayed voltage recovery phenomenon mitigation method implementation under voltage load shedding on the korean power system considering induction motor load.

전력계통 신뢰도 강화를 위한 저주파계전기의 적정 부하차단 방안 (Load Shedding Schemes of Under Frequency Relay to Improve Reliability in Power Systems)

  • 김규호;송경빈;김일동;양정재;조범섭
    • 전기학회논문지
    • /
    • 제59권7호
    • /
    • pp.1214-1220
    • /
    • 2010
  • This paper proposes an efficient under frequency relay load shedding scheme for the korea power system which is more than two times than the system size and its capacity of the power system 10 years ago. The proposed method is keeping the power system stability and supports for the operating system during critical situations such as big disturbances and unstable in supply and demand. In order to determine the number of load shedding steps, the load to be shed per step, and frequency level, it is necessary to investigate and analyze maximum losses of generation due to the biggest contingency, maximum system overload, maximum keeping frequency, maximum load to be shed, and recovery frequency. The proposed method is applied to Off-peak load(25,400MW) and Peak load(62,290MW) of Korea Electric Power Corporation to demonstrate its effectiveness.

Implementation of Under Voltage Load Shedding for Fault Induced Delayed Voltage Recovery Phenomenon Alleviation

  • Lee, Yun-Hwan;Park, Bo-Hyun;Oh, Seung-Chan;Lee, Byong-Jun;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.406-414
    • /
    • 2014
  • Significant penetration of induction motor loads into residential neighborhood and commercial regions of local transmission systems at least partially determine a vulnerability to a fault induced delayed voltage recovery (FIDVR) event. Highly concentrated induction motor loads with constant torque could stall in response to low voltages associated with system faults. FIDVR is caused by wide spread stalling of small HVAC units (residential air conditioner) during transmission level faults. An under voltage load shedding scheme (UVLS) can be an effective component in a strategy to manage FIDVR risk and limit the any potential disturbance. Under Voltage Load Shedding take advantage of the plan to recovery the voltage of the system by shedding the load ways to alleviation FIDVR.

경험적 법칙을 사용한 부하 차단에 관한 연구 (Load shedding algorithm based on heuristic search)

  • 백영식;권영한;정태호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.366-369
    • /
    • 1991
  • Load shedding algorithm has been developed using heuristic search and D.C flow method. The line flow error with a D.C method was improved in this paper. Minimization of load shedding was obtained with heuristic search method. Although analytical method have been mixed with expert algorithm the C language fitted well for this purpose.

  • PDF

공간 데이터스트림의 입력 빈도와 데이터 밀집도 기반의 동적 부하제한 기법 (Dynamic Load Shedding Scheme based on Input Rate of Spatial Data Stream and Data Density)

  • 정원일
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2158-2164
    • /
    • 2015
  • u-GIS 환경에서는 실시간으로 유입되는 공간 데이터 스트림으로 인해 발생되는 부하를 제한하기 위한 연구가 계속되고 있다. 그러나 기존의 비공간 데이터 기반의 부하 제한 기법은 공간 데이터의 특성을 고려하지 않아 공간 질의 처리의 정확도를 감소시킨다. 또한, 공간 데이터 기반의 부하 제한 기법도 공간 데이터 스트림의 입력 빈도 변화와 공간 데이터의 밀집도를 반영하지 않아 질의 처리 정확도와 질의 처리 성능이 저하되는 문제가 존재한다. 이에 본 논문에서는 u-GIS 환경에서 부하 발생 빈도를 최소화하고 연속 질의 처리 성능과 정확도를 향상시키기 위해 공간 데이터의 밀집도와 공간데이터스트림의 입력 변화량을 이용하여 동적으로 부하를 제한하는 기법을 제안한다. 제안 기법에서는 부하제한 요구시 공간 이용도에 따라 질의에 참여할 확률이 낮은 데이터를 샘플링함으로써 연속 질의 처리 결과의 정확도와 질의 처리 속도를 향상시킬 수 있다.

Synchro-Phasor 데이터를 이용한 수도권 전압 안정화 제어 스킴 개발에 관한 연구 (Study on the Development of Load Shedding Scheme for Improving Voltage Stability of Seoul Metropolitan Area using Synchro-phasor Data)

  • 신정훈;남수철;백승묵;이재걸;문승필;김태균
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1530-1539
    • /
    • 2010
  • Recent technology advancement related to computer & communication and measuring devices allows system operators to adopt more intelligent monitoring and control systems to their power systems in order to prevent massive system blackout. Among them, wide-area monitoring and control(WAMAC) system based on synchro-phasor technology has been widely applied to power systems for their own purposes. In this paper, the study on the development of load shedding scheme to improve voltage stability in KEPCO system is introduced. Summary of WAMAC technology being developed and applied in the world through extensive literature survey is proposed. And methodology to develop voltage stability index and multi-step load shedding scheme based on synchro-phasor data is also presented.

우선도를 고려한 지역 부하차단에 관한 전문가 시스템 (An Expert system On Local load shedding With priority)

  • 유미복;김재철;김응상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.161-164
    • /
    • 1992
  • In operation of power systems, operators must solve overloads in abnormal conditions instantaneously for restoring the power system to normal state. Earlier works proposed the power flow distribution and the load shedding decision, developed by the expert system, for settling overloads. This paper presents a method for solving special conditions in the earlier works which requires less amount of loads than that of the load shedding, in particular, of the load shedding considering the priority. This paper uses the effort system to improve the ability of a beginner as well as of trained operators for operating the power system during emergency operation. To prove efficiency of the proposed method, this paper has adopted the model system with 13 bus for obtaining simulation results and used the prolog language to implement the system.

  • PDF