• Title/Summary/Keyword: Load Master

Search Result 134, Processing Time 0.028 seconds

A Study on Result Differences of Flight's Weight and Balance by Load Master (항공기 탑재 관리사들의 개인 특성에 따른 Weight and Balance C.G. 결과)

  • Lee, Gyu-Jin;Lee, Yun-Cheol
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.23 no.3
    • /
    • pp.81-87
    • /
    • 2015
  • Load master is authorized to be controlled all of loading stuffs for safety of flight such as passenger, baggage, cargo and e.t.c. There are many things are missed even though the weight and balance is the most important process. This study analyzes how the differences of C.G. by among ten load masters of each careers. This study is tested how load-master takes load-control by the respective result based on differences of each practical experiences, gender and a number of certification. In result, all of load masters set C.G. on the stability region. But the practical experience of load master is relative to set better C.G. for economical effectiveness of weight and balance control work.

Verification and Application of MASTER for Load Follow Operation

  • Park, Yong-Soo;Cho, Byung-Oh;Lee, Chang-Ho;Jung, Yil-Sup;Park, Chan-Oh
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.231-236
    • /
    • 1996
  • The xenon dynamics module in the nuclear design code MASTER was verified through a simulation calculation. The simulation result shows that the xenon dynamics module in MASTER can trace and predict xenon behavior with accuracy under any core transient state and therefore can simulate load follow operations.

  • PDF

Dynamic design of master robots (마스터 로봇의 동역학적 설계)

  • 김창호;조국훈;한창수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1293-1296
    • /
    • 1997
  • We investigate a design methodology for master arm which is employed in remote-site control. Though counter-balancing has been employed for the purpose of lessening the actuator loads, it results in the increase of dynamic load at the task position. Therefore, there exist a trade-off between counter-balacing and dynamic performance. The concept of a composite index is introduced to simulataneously consider those two effects in the design of master arms. Several alternative designs of master arms are suggested.

  • PDF

An Experimental Study on The Friction Coefficient of Rubbers for Clutch Master Cylinder Cup-Seals (클러치 마스터실린더 컵-시일 고무의 마찰계수 실험 연구)

  • 이재천;임문혁;이병수;장지현;정용승;허만대;최병기
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.112-118
    • /
    • 2003
  • The friction coefficients of the rubber for clutch master cylinder were experimentally measured in this study. The cylindrical rubber samples for primary cup-seal and secondary cup-seal were tested against the aluminum or the steel plates of master cylinder housing under the various conditions of brake oil temperatures and normal loads. Dry sliding friction coefficients were also measured under various load conditions. The test revealed following results. First, the friction coefficient under fluid lubrication condition in general decreases, as the oil temperature or normal load increases. Second, the steel plate of low surface roughness yielded comparatively low friction coefficient on the range of 0.30∼0.67. On the other hand, the aluminum plate of high surface roughness yielded high friction coefficient on the range of 0.31∼1.15. Third, the friction coefficient of dry surface contact decreases as the normal load increases. This is contrary to the general principle of friction coefficient between metal plates.

Study of improvement control logic about unit master control(UMC) (Unit master control(UMC) 제어로직 개선에 관한 연구)

  • Park, Doo-Yong;Lim, Gyun-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1707_1708
    • /
    • 2009
  • Unit master control(UMC)는 발전소의 요구 부하신호를 설정하는 최상위의 제어레벨이며 UMC의 설정값은 자동급전 지령신호(Automatic Dispatch System : ADS) 또는 운전원이 설정하는 값에 따라 보일러 및 터빈 Master에 Unit 요구 신호를 출력하여 하위제어 레벨인 공기, 연료, 급수 등을 조절할 수 있는 기기에 Unit 부하 요구 신호(Unit Load Demand : ULD)에 따라 제어 되도록 하는 방법으로서, Unit 목표부하 설정, Unit 목표부하 상/하한 제한, 목표부하 변화율 제한, 주파수 보정, Runback/Rundown/ Runup, 보일러 및 터빈 Demand 신호생성의 기능을 가지고 있다.

  • PDF

Parallel Sensorless Speed Control using Power Angle for Dual SPMSMs Fed by a Single Inverter (단일 인버터 기반 두 대의 영구자석 동기전동기 병렬운전에서 전력각을 이용한 속도제어기법)

  • Kim, Kyung-Hoon;Yun, Chul;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1481-1487
    • /
    • 2017
  • This paper proposes a sensorless speed control algorithm for parallel-connected dual Surface-mounted Permanent Magnet Synchronous Motors fed by a single inverter. For stable parallel operation of synchronous motors with a single inverter, each motor has to be constantly kept in the synchronization state regardless of load torque. If the master motor with the larger load is controlled, the synchronous state will be maintained. Therefore, detection of the master motor is essential. Conventionally, the master motor is determined by comparing the rotor position error from the relation between the back-EMF for torque angle and the flux position. consequently, the position sensor is deemed essential for finding the rotor position. In this paper, we proposed a method that decides the magnitude of the load from the power angle of two motors due to the load variation and selects the motor to control through the sign function for the sensorless speed control without the position sensor. The results of simulation and experiment conducted verify the efficacy of the proposed method.

Master-Slave type DC-DC Converters Parallel Operation by ZCT method (ZCT방식의 master-slave형 DC-DC컨버터 병렬운전)

  • 박상은;송승찬;진정태;이기홍;성세진
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.655-658
    • /
    • 1999
  • In this paper, Parallel operation of two DC-DC converters which we have ever done before need two CTs to do load current sharing. However, we have proposed a new method called ZCT method that can share load current with only a CT as doing parallel operation two converters with same converter capacity. To confirm parallel performance by a proposed DC-DC converter parallel operation method, we have done computer simulation and experiment. It is certain that we have showed to achieve two converters current sharing performance efficiently through simulation and experiment at result.

  • PDF

Web Server Cluster's Load Balancing for Security Session

  • Kim Seok-Soo
    • Journal of information and communication convergence engineering
    • /
    • v.3 no.2
    • /
    • pp.93-95
    • /
    • 2005
  • In order to create security session, security keys are preconfigured between communication objects. For this purpose, Handshake Protocol exists. The pre-master secret key that is used in this process needs to interpreted by a server to create master secret key, whose process requires a big calculation, resulting in deteriorating system's transmission performance. Therefore, it is helpful in increasing transmission speed to reuse secret keys rather than to create them at every connection.

Development of Human Interface System for IMS : Dynamic Design of Master Robots (IMS를 위한 Human Interface 시스템 개발 : 마스터 로봇의 동역학적 설계)

  • 김창호;이병주;한창수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.12
    • /
    • pp.148-161
    • /
    • 1998
  • We investigate a design methodology for master arm which is employed in remote-site control. Though counter-balancing has been employed for the purpose of lessening the actuator loads, it results in the increase of dynamic load at the task position. Therefore, there exists a trade-off between counter-balancing and dynamic performance. The concept of a composite index is introduced to simultaneously consider those two effects in the design of master arms. Several alternative designs of master arms are suggested.

  • PDF

Design and Implementation of a Fast DIO(Digital I/O) System (고속 DIO(Digital I/O) 시스템의 설계와 제작)

  • Lee, Jong-Woon;Cho, Gyu-Sang
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.5
    • /
    • pp.229-235
    • /
    • 2006
  • High speed PC-based DIO(Digital I/O) system that consists of a master device and slave I/O devices is developed. The PCI interfaced master device controls all of serial communications, reducing the load on the CPU to a minimum. The slave device is connected from the master device and another slave device is connected to the slave device, it can repeated to maximum 64 slave devices. The slave device has 3 types I/O mode, such as 16 bits input-only, 16 bits output-only, and 8bits input-output. The master device has 2 rings which can take 64 slaves each. Therefore, total I/O points covered by the master is 2048 points. The slave features 3 types of input/output function interchangeability by DIP switch settings. Library, application, and device driver software for the DIO system that have a secure and a convenient functionality are developed.