• 제목/요약/키워드: Load Distribution Method

검색결과 1,426건 처리시간 0.026초

Optimal Calculation Method of Distribution Loss in Distribution Systems

  • Rho Dae-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.109-115
    • /
    • 2005
  • Recently, the needs and concerns regarding power loss have been increasing according to energy conservation at the level of the national policies and the business strategies of power utilities. In particular, the issue of power loss is the main factor for determining rates for electrical consumption in the deregulation of the electrical industry. However, because of the lack of management for power loss load factors (LLF) it is difficult to make a calculation for power loss and to make a decision concerning the electric rates. Furthermore, loss factor (k-factor) in Korea, which is of primary significance in the calculation of distribution power loss, has been used as a fixed value of 0.32 since the fiscal year 1973. Therefore, this study presents the statistical calculation methods of the loss factors classified by load types and seasons by using the practical data of 65 primary feeders that have been selected by appropriate procedures. Based on the above, the algorithms and methods, as well as the optimal method of the distribution loss management classified by facilities such as primary feeders, distribution transformers and secondary feeders is presented. The simulation results demonstrate the effectiveness and usefulness of the proposed methods.

Reliability Evaluation of a Distribution System with wind Turbine Generators Based on the Switch-section Partitioning Method

  • Wu, Hongbin;Guo, Jinjin;Ding, Ming
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.575-584
    • /
    • 2016
  • Considering the randomness and uncertainty of wind power, a reliability model of WTGs is established based on the combination of the Weibull distribution and the Markov chain. To analyze the failure mode quickly, we use the switch-section partitioning method. After defining the first-level load zone node, we can obtain the supply power sets of the first-level load zone nodes with each WTG. Based on the supply sets, we propose the dynamic division strategy of island operation. By adopting the fault analysis method with the attributes defined in the switch-section, we evaluate the reliability of the distribution network with WTGs using a sequential Monte Carlo simulation method. Finally, using the IEEE RBTS Bus6 test system, we demonstrate the efficacy of the proposed model and method by comparing different schemes to access the WTGs.

Multi-criteria performance-based optimization of friction energy dissipation devices in RC frames

  • Nabid, Neda;Hajirasouliha, Iman;Petkovski, Mihail
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.185-199
    • /
    • 2020
  • A computationally-efficient method for multi-criteria optimisation is developed for performance-based seismic design of friction energy dissipation dampers in RC structures. The proposed method is based on the concept of Uniform Distribution of Deformation (UDD), where the slip-load distribution along the height of the structure is gradually modified to satisfy multiple performance targets while minimising the additional loads imposed on existing structural elements and foundation. The efficiency of the method is demonstrated through optimisation of 3, 5, 10, 15 and 20-storey RC frames with friction wall dampers subjected to design representative earthquakes using single and multi-criteria optimisation scenarios. The optimum design solutions are obtained in only a few steps, while they are shown to be independent of the selected initial slip loads and convergence factor. Optimum frames satisfy all predefined design targets and exhibit up to 48% lower imposed loads compared to designs using a previously proposed slip-load distribution. It is also shown that dampers designed with optimum slip load patterns based on a set of spectrum-compatible synthetic earthquakes, on average, provide acceptable design solutions under multiple natural seismic excitations representing the design spectrum.

Temperature dependent buckling analysis of graded porous plate reinforced with graphene platelets

  • Wei, Guohui;Tahouneh, Vahid
    • Steel and Composite Structures
    • /
    • 제39권3호
    • /
    • pp.275-290
    • /
    • 2021
  • The main purpose of this research work is to investigate the critical buckling load of functionally graded (FG) porous plates with graphene platelets (GPLs) reinforcement using generalized differential quadrature (GDQ) method at thermal condition. It is supposed that the GPL nanofillers and the porosity coefficient vary continuously along the plate thickness direction. Generally, the thermal distribution is considered to be nonlinear and the temperature changing continuously through the thickness of the nanocomposite plates according to the power-law distribution. To model closed cell FG porous material reinforced with GPLs, Halpin-Tsai micromechanical modeling in conjunction with Gaussian-Random field scheme are used, through which mechanical properties of the structures can be extracted. Based on the third order shear deformation theory (TSDT) and the Hamilton's principle, the equations of motion are established and solved for various boundary conditions (B.Cs). The fast rate of convergence and accuracy of the method are investigated through the different solved examples and validity of the present study is evaluated by comparing its numerical results with those available in the literature. A special attention is drawn to the role of GPLs weight fraction, GPLs patterns through the thickness, porosity coefficient and distribution of porosity on critical buckling load. Results reveal that the importance of thermal condition on of the critical load of FGP-GPL reinforced nanocomposite plates.

Bearing Load Distribution Studies in a Multi Bearing Rotor System and a Remote Computing Method Based on the Internet

  • Yang, Zhao-Jian;Peng, Ze-Jun;Kim, Seock-Sam
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.946-954
    • /
    • 2004
  • A model in the form of a Bearing Load Distribution (BLD) matrix in the Multi Bearing Rotor System (MBRS) is established by a transfer matrix equation with the consideration of a bearing load, elevation and uniform load distribution. The concept of Bearing Load Sensitivity (BLS) is proposed and matrices for load and elevation sensitivity are obtained. In order to share MBRS design resources on the Internet with remote customers, the basic principle of Remote Computing (RC) based on the Internet is introduced ; the RC of the BLD and BLS is achieved by Microsoft Active Server Pages (ASP) technology.

배전용 변압기 부하사용 패턴분류 (Pattern Classification of Load Demand for Distribution Transformer)

  • 윤상윤;김재철;이영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.89-91
    • /
    • 2001
  • This paper presents the result of pattern classification of load demand for distribution transformer in domestic. The field data of load demand is measured using the load acquisition device and the measurement data is used for the database system for load management of distribution transformed. For the pattern classification, the load data and the customer information data are also used. The K-MEAN method is used for the pattern classification algorithm. The result of pattern classification is used for the 2-step format of load demand curve.

  • PDF

데이터베이스를 이용한 부하패턴별 수용가 특징 모델링 (Customer Characteristics Modeling for Each Load Pattern using the Database)

  • 이영석;김재철;오정환;윤상윤;박창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.416-418
    • /
    • 2001
  • This Paper presents the 2-step load cycle of daily load curve for representative load pattern of power distribution transformer. We decide the representative load pattern of distribution transformer in domestic using the pattern classification algorithm. The K-mean method is used for the pattern classification algorithm. The acquisition equipment of field load data is utilized for 96-sample distribution transformers and the field data is used in the construction of the database for the creation of daily load pattern.

  • PDF

Fluctuating wind loads across gable-end buildings with planar and curved roofs

  • Ginger, J.D.
    • Wind and Structures
    • /
    • 제7권6호
    • /
    • pp.359-372
    • /
    • 2004
  • Wind tunnel model studies were carried out to determine the wind load distribution on tributary areas near the gable-end of large, low-rise buildings with high pitch planar and curved roof shapes. Background pressure fluctuations on each tributary area are described by a series of uncorrelated modes given by the eigenvectors of the force covariance matrix. Analysis of eigenvalues shows that the dominant first mode contributes around 40% to the fluctuating pressures, and the eigenvector mode-shape generally follows the mean pressure distribution. The first mode contributes significantly to the fluctuating load effect, when its influence line is similar to the mode-shape. For such cases, the effective static pressure distribution closely follows the mean pressure distribution on the tributary area, and the quasi-static method would provide a good estimate of peak load effects.

터널 설계조건을 고려한 하중분배율의 정량적 산정에 관한 연구 -ring-cut 굴착공법을 중심으로- (A Study on the Quantitative Evaluation of the Load Distribution Factors Considering the Design Conditions of Tunnel Especially for the Ring-cut Excavation Method)

  • 장석부;문현구
    • 한국지반공학회지:지반
    • /
    • 제14권5호
    • /
    • pp.5-16
    • /
    • 1998
  • 공사중 터널은 막장부의 종방향 및 횡방향 아치거동에 의하여 주변 지반은 3차원적 변형거동을 보이나, 터널 안정성 해석에는 전산효율 등의 이유로 2차원 수치해석법이 일반적으로 적용되고 있다. 하중분배율은 터널의 굴진효과를 고려하기 위하여 2차원 해석에 도입된 것으로 지반변위, 숏크 리트 및 록볼트와 같은 1차 지보재의 하중 등과 같은 해석결과에 큰 영향을 미친다. 또한, 3차원 해석을 이용한 기존의 연구에 의하면, 지반의 변형특성, 터널크기, 굴진장 등이 하중분배율에 주요한 영향을 미친다는 사실이 입증되었다. 그러나, 설계조건에 대한 하중분배율의 정량적 산정법의 부재 로 인하여 실제 해석시에는 설계조건을 무시한 하중분배율이 적용되고 있는 실정이다. 이에, 본 논문에서는 기존 연구(정 대열, 1993)에서 제시한 72개의 3차원 해석결과에 대한 회귀분석을 통하여 하중분배율을 정량적으로 산정할 수 있는 방법을 제시하였다. 또한. ring-cut공법은 막장의 자립성 이 매우 불량한 조건에 적용되는 공법임에도 불구하고 기존의 2차원 해석 법으로는 막장코아의 진 지효과를 고려하지 못하는 문제점이 있었다. 따라서, 2차원 및 3차원 수치해석을 통하여 ring-cut공 법에 대한 기존 해석법의 문제점을 검토하였으며 본 공법에 대한 하중분배율의 보정치를 제시하였 다.

  • PDF

부하불평형 및 부하모형을 고려한 복합배전계통의 분산형전원의 연계 방안 (Interconnection of Dispersed Generation Systems considering Load Unbalance and Load Model in Composite Distribution Systems)

  • 이유정;김규호;이상근;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.266-274
    • /
    • 2004
  • This paper presents a scheme for the interconnection of dispersed generator systems(DGs) based on load .unbalance and load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The unbalance is involved with many single-phase line segment. . Voltage profile improvement and system loss minimization by installation of DGs depend greatly on how they are placed and operated in the distribution systems. So, DGs can reduce distribution real power losses and replace large-scale generators if they are placed appropriately in the distribution systems. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 13 bus and 34 bus test systems to demonstrate its effectiveness.