• Title/Summary/Keyword: Load Deviation

Search Result 344, Processing Time 0.024 seconds

Prediction of Thermal Load Distribution and Temperature of the Superheater in a Tangentially Fired Boiler (접선 연소식 보일러의 최종 과열기 열부하 분포 및 튜브 온도 예측에 관한 연구)

  • Park, Ho-Young;Sea, Sang-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.478-485
    • /
    • 2008
  • The extreme steam temperature deviation experienced in the superheater of a tangentially fired boiler can seriously affect its economic and safe operation. This temperature deviation is one of the main causes of boiler tube failures. The steam temperature deviation is mainly due to the thermal load deviation in the lateral direction of the superheater. The thermal load deviation consists of several causes. One of the causes is the non-uniform heat flow distribution of burnt gas on the superheater tube system. This distribution is very difficult to measure in situ using direct experimental techniques. So, we need thermal load model to estimate the tube temperature. In this paper, we propose a thermal load distribution model by using CFD analysis and plant data. We successfully predict the tube temperature and the steam flow rate in a final superheater system from the thermal load model and one dimensional heat-flow system analysis. The proposed model and analysis method would be valuable in preventing the frequent tube failure of the final superheater tubes.

Effect on Improvement of Muscle Strength Imbalance according to Load Deviation Pattern of Left and Right Arms in Upper Limbs (상지 좌우 운동부하 편차방식이 근력 불균형 개선에 미치는 영향)

  • Kang, Seung-Rok;Seo, Shin-Bae;Jeong, Gu-Young;Bae, Jong-Jin;Yu, Chang-Ho;Yu, Mi;Moon, Dong-An;Jeong, Jang-Sik;Kwon, Tae-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.9
    • /
    • pp.1026-1034
    • /
    • 2012
  • The purpose of this study was to verify the validation of effect on improvement of muscle strength unbalance according to exercise load deviation during rowing exercise. We performed evaluation of muscular activity and joint torque before the test. We recruited twenty subjects who one side's muscle strength is bigger in more 20% than other side. Subjects divided two groups. One is dominant left side and the other was dominant right side. Subjects performed rowing exercise in electric load deviation rowing equipment (Robo.gym, Humonic Co., Ltd., Daegu, Korea). Exercise performed four sets a day including 25 times a set, and three days a week. Measurements consist of evaluation of muscular activity and joint torque. Exercise load deviation adapted that different value of muscle strength in both arms multiplied 1RM% and added 1RM 50%. The results in adapted load deviation showed that the differences of maximal peak torque in 22.75% were getting increase significantly during exercise in 5.72%. This interpreted that rowing exercise with loading deviation types could provide muscle strength and muscular endurance exercise in same time for balance. Our study found out that loading deviation could provide muscle strength and muscular endurance exercise for improving muscle unbalance.

The Effect on Improvement of Muscle Strength Imbalance According to Load Deviation Protocol of Whole Body Vibration Exercise (부하 편차 방식의 전신진동운동이 하지 근력 불균형 개선에 미치는 효과)

  • Seo, Shin Bae;Kang, Seung Rok;Yu, Chang Ho;Min, Jin Young;Kwon, Tae Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.10
    • /
    • pp.1095-1101
    • /
    • 2013
  • The purpose of this study was to verify the effect on improvement of muscle strength unbalance according to load deviation protocol during whole body vibration exercise. Seventeen female volunteers (age $22{\pm}3$ years, height $160{\pm}4.9$ cm, weight $49{\pm}.8$ kg) participated in this experiment. The subjects performed squat exercise in WBV platform. Exercise were performed five set a day including 15 time a set, three days a week, and during 4 weeks. Vibration stimulus was 25Hz as frequency and intensity was dominant leg 1mm and non-dominant leg 4mm. The results in WBV group showed that the differences of peak torque in 16% were getting decreasing significantly after 4 weeks from 16.2% to 5.2%. This result means that WBV with load deviation protocol could provide muscle strength exercise for muscle strength balance. Our study found out that WBV of load deviation protocol could provide muscle strength exercise for improving muscle imbalance.

Asymptotics in Load-Balanced Tandem Networks

  • Lee, Ji-Yeon
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.155-162
    • /
    • 2003
  • A tandem network in which all nodes have the same load is considered. We derive bounds on the probability that the total population of the tandem network exceeds a large value by using its relation to the stationary distribution. These bounds imply a stronger asymptotic limit than that in the large deviation theory.

  • PDF

Asymptotics in Load-Balanced Tandem Networks

  • Lee, Ji-Yeon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.3
    • /
    • pp.715-723
    • /
    • 2003
  • A tandem network in which all nodes have the same load is considered. We derive bounds on the probability that the total population of the tandem network exceeds a large value by using its relation to the stationary distribution. These bounds imply a stronger asymptotic limit than that in the large deviation theory.

  • PDF

Transient Performance Improvement in the Boundary Control of Boost Converters using Synthetic Optimized Trajectory

  • Feng, Gaohui;Yuan, Liqiang;Zhao, Zhengming;Ge, Junjie;Ye, Xiuxi;Lu, Ting
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.584-597
    • /
    • 2016
  • This paper focuses on an improvement in the transient performance of Boost converters when the load changes abruptly. This is achieved on the basis of the nature trajectory in Boost converters. Three key aspects of the transient performance are analyzed including the storage energy change law in the inductors and capacitors of converters during the transient process, the ideal minimum voltage deviation in the transient process, and the minimum voltage deviation control trajectory. The changing relationship curve between the voltage deviation and the recovery time is depicted through analysis and simulations when the load suddenly increases. In addition, the relationship curve between the current fluctuation and the recovery time is obtained when the load suddenly decreases. Considering the aspects of an increasing and decreasing load, this paper proposes the transient performance synthetic optimized trajectory and control laws. Through simulation and experimental results, the transient performances are compared with the other typical three control methods, and the ability of proposed synthetic trajectory and control law to achieve optimal transient performance is verified.

A Study on the Parallel Operation Control Technique of On-line UPS System (무정전전원장치의 병렬운전 제어기법에 관한 연구)

  • 곽철훈;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.585-592
    • /
    • 2003
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between Inverters on synchronous d-q reference frame.

A Study on the Uniform Distribution of Steam Flow in the Superheater Tube System (과열기 관군에서의 증기유량 균일 배분 연구)

  • Park, Ho-Young;Kim, Sung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.416-426
    • /
    • 2008
  • The boiler tube failure often experienced in the superheater of a utility boiler can seriously affect the economic and safe operation of the power plant. It has been known that this failure is mainly caused by the thermal load deviation in the superheater tube system, and deeply intensified by the non-uniform distribution of steam flow rates. The nonuniform steam flow is distinctively prominent at low power load rather than at full power load. In this paper, we analyze the steam flow distribution in the superheater tube system by using one dimensional flow network model. At 30% power load, the deviation of steam flow rate is predicted to be within 0.8% of the averaged flow rate. This deviation can be reduced to 0.1% and 0.07% by assuming two cases, that is, the removal of 13th tube at each tube rows and the installation of intermediate header, respectively. The assumed two cases would be effective for the uniform steam flow distribution across 85 superheater tube rows.

Psychophysical Stess Depending on Repetition of Wrist Motion and External Load (손목 동작의 반복과 외부 부하에 따른 심물리학적 부하)

  • Kee, Do-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.123-128
    • /
    • 2004
  • This study investigated effect of arm posture, repetition of wrist motion and external load on perceived discomfort. The arm postures were controlled by shoulder flexion, elbow flexion, and ist motions such as flexion, extension, radial deviation and ulnar deviation. An experiment was conducted to measure discomfort scores for experimental treatments using the magnitude estimation, in which the L16 orthogonal array was adopted for reducing the size of experiment. The results showed that while the effect of the shoulder flexion, repetition of wrist motion and external load was statistically significant at $\alpha=0.05$or 0.10, that of the elbow and wrist motions was not. Discomfor ratings increased linearly as levels of wrist repetition and external load increased. This implies that the existing posture classification schemes such as OWAS, RULA, which do not properly consider effect of motion repetition and external load, may underestimate postural load. Based on the regression equation for wrist repetition and external load, isocomfort region indicating the region within which discomfort scores were expected to be the same was proposed. It is recommended that when assessing risk of postures or developing new posture classification schemes, motion repetition and external load as well as posture itself be fully taken into consideration for precisely evaluating postural stress.