• 제목/요약/키워드: Load Capacity Coefficient

검색결과 177건 처리시간 0.028초

해수열원 스크류 히트펌프의 연간 난방운전 성능 시뮬레이션 (A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump)

  • 백영진;김민성;장기창;강병찬;라호상;김현주
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.488-493
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

  • PDF

Test and simulation of circular steel tube confined concrete (STCC) columns made of plain UHPC

  • Le, Phong T.;Le, An H.;Binglin, Lai
    • Structural Engineering and Mechanics
    • /
    • 제75권6호
    • /
    • pp.643-657
    • /
    • 2020
  • This study presents experimental and numerical investigations on circular steel tube confined ultra high performance concrete (UHPC) columns under axial compression. The plain UHPC without fibers was designed to achieve a compressive strength ranged between 150 MPa and 200 MPa. Test results revealed that loading on only the UHPC core can generate a significant confinement effect for the UHPC core, thus leading to an increase in both strength and ductility of columns, and restricting the inherent brittleness of unconfined UHPC. All tested columns failed by shear plane failure of the UHPC core, this causes a softening stage in the axial load versus axial strain curves. In addition, an increase in the steel tube thickness or the confinement index was found to increase the strength and ductility enhancement and to reduce the magnitude of the loss of load capacity. Besides, steel tube with higher yield strength can improve the post-peak behavior. Based on the test results, the load contribution of the steel tube and the concrete core to the total load was examined. It was found that no significant confinement effect can be developed before the peak load, while the ductility of post-peak stage is mainly affected by the degree of the confinement effect. A finite element model (FEM) was also constructed in ABAQUS software to validate the test results. The effect of bond strength between the steel tube and the UHPC core was also investigated through the change of friction coefficient in FEM. Furthermore, the mechanism of circular steel tube confined UHPC columns was examined using the established FEM. Based on the results of FEM, the confining pressures along the height of each modeled column were shown. Furthermore, the interaction between the steel tube and the UHPC core was displayed through the slip length and shear stresses between two surfaces of two materials.

Fundamental Properties of Porous Concrete by Aggregate Size

  • Kim, Moo-Han;Kim, Gyu-Yong;Baik, Yong-Kwan;Kim, Jae-Hwan;Cho, Bong-Suk
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권2E호
    • /
    • pp.117-124
    • /
    • 2006
  • Porous concrete has been used recently for the purpose of decreasing the load on the earth environment. It consists solely of cement, water and coarse aggregate of uni form size. Its fundamental properties are considerably affected by the physical properties of aggregate because the aggregate is the main material for the most part in its mix proportion. Because of this reason, this study carried out an investigation of the influence of the size and type of aggregate on the fundamental properties of porous concrete. It is shown that the fundamental properties of porous concrete was seldom affected by the size of aggregate except for the case of using $2.5{\sim}5mm$ aggregate but varied significantly by the type of aggregate. In particular, the compressive strength of porous concrete using $2.5{\sim}5mm$ aggregate was much higher than that using other aggregate, and its void ratio and coefficient of permeability was lower. Moreover, the capacity to maintain the permeability of porous concrete was found to vary by the size and type of aggregate. Of particular notice was that it decreased greatly when $2.5{\sim}5mm$ aggregate was used. Unlike ordinary concrete, porous concrete exhibited very high dynamic modulus of elasticity at early age and continued to increase but slowly afterwards.

축열조를 채용한 수평형 지열원 히트펌프 온실 난방 시스템에 관한 연구 (A Study on the Horizontal Ground Source Beat Pump Greenhouse Heating System with Thermal Storage Tank)

  • 박용정;김경훈
    • 에너지공학
    • /
    • 제15권3호
    • /
    • pp.194-201
    • /
    • 2006
  • 온실은 작물의 성장조건을 맞추기 위해서 야간 및 추운 날에는 난방을 해야 한다. 지열원 히트펌프 시스템은 냉난방 시스템에서 두드러진 관심을 보이고 있다. 축열조를 채용한 수평형 지열원 히트펌프 시스템을 온실에 적용하여 성능특성을 조사하였다. 그리고 축열조를 채용한 이유를 자세하게 설명하였다. 축열조는 지열원 히트펌프 시스템의 난방능력보다 큰 난방부하를 대응할 수 있다. 연구 결과, 시스템전체의 성능계수는 2.69로 나타났다.

Study on energy dissipation mechanism of cross-shaped BRB with built-up angle steel

  • Yanmin Yang;Ying Xiong;Peng Wang;Xiangkun Meng;Tianyuan Cai
    • Earthquakes and Structures
    • /
    • 제25권2호
    • /
    • pp.113-123
    • /
    • 2023
  • A novel type of buckling restrained brace with built-up angle steel was developed. The core segment was formed by welding angle steel, and the middle section was reduced by cutting technology to solve the problem that the end of BRB was easy to buckle. The experimental program has been undertaken to study the performance of BRBs with different unbonded materials (silica gel, kraft paper) and different filler materials (ordinary concrete, full light-weight concrete). Four specimens were designed and fabricated for low cycle reciprocating load tests to simulate horizontal seismic action. The failure mode, hysteretic curves, tension-compression unbalance coefficient and other mechanical parameters were compared and analyzed. The finite element software ABAQUS was used to conduct numerical simulation, and the simulation results were compared with the experimental phenomena. The test results indicated that the hysteretic curve of each specimen was plump. Sustaining cumulative strains of each specimen was greater than the minimum value of 200 required by the code, which indicated the ductility of BRB was relatively good. The energy dissipation coefficient of the specimen with silica gel as unbonded material was about 13% higher than that with kraft paper. The experimental results were in good agreement with the simulation results.

원심모형시험에 의한 편심하중을 받는 얕은기초의 거동 (The Behavior of Shallow Foundation under Eccentric Loads by Centrifuge Model Experiment)

  • 유남재;이명욱;박병수;정길수
    • 산업기술연구
    • /
    • 제22권A호
    • /
    • pp.229-240
    • /
    • 2002
  • This paper is an experimental and numerical work of Investigating the bearing capacity of shallow foundation of rubble mound under eccentric loads. Parametric centrifuge model tests at the 50g level environments with the model footings in the form of strip footing were performed by changing the loading location of model footing, relative density and materials for ground foundation. For the model ground, crushed rock sampled from a rocky mountain was prepared with a grain size distribution of having an identical coefficient of uniformity to the field condition. Model ground was also prepared with relative densities of 50 % and 80 %. For loading condition, model tests with and without eccentric load were carned out to investigate the effect of eccentric loads and a numerical analysis with the commertially available software of FLAC was performed. For numerical estimation with FLAC, the hyperbolic model of a nonlinear elastic constitutive relationship was used to simulate the stress-stram constitutive relationship of model ground and a series of triaxial compression test were carried out to find the parameters for this model Test results were analyzed and compared with Meyerhof method (1963), effective area method based on the limit equilibrium method, and a numerical analysis with FLAC.

  • PDF

Finite element and design code assessment of reinforced concrete haunched beams

  • Gulsan, Mehmet Eren;Albegmprli, Hasan M.;Cevik, Abdulkadir
    • Structural Engineering and Mechanics
    • /
    • 제66권4호
    • /
    • pp.423-438
    • /
    • 2018
  • This pioneer study focuses on finite element modeling and numerical modeling of three types of Reinforced Concrete Haunched Beams (RCHBs). Firstly, twenty RCHBs, consisting of three types, and four prismatic beams which had been tested experimentally were modeled via a nonlinear finite element method (NFEM) based software named as, ATENA. The modeling results were compared with experimental results including load capacity, deflection, crack pattern and mode of failure. The comparison showed a good agreement between the results and thus the model used can be effectively used for further studies of RCHB with high accuracy. Afterwards, new mechanism modes and design code equations were proposed to improve the shear design equation of ACI-318 and to predict the critical effective depth. These equations are the first comprehensive formulas in the literature involving all types of RCHBs. The statistical analysis showed the superiority of the proposed equation to their predecessors where the correlation coefficient, $R^2$ was found to be 0.89 for the proposed equation. Moreover, the new equation was validated using parametric and reliability analyses. The parametric analysis of both experimental and predicted results shows that the inclination angle and the compressive strength were the most influential parameters on the shear strength. The reliability analysis indicates that the accuracy of the new formulation is significantly higher as compared to available design equations and its reliability index is within acceptable limits.

지열원 히트펌프시스템의 실사용을 통한 난방성능연구 (Heating Performance of a Ground Source Heat Pump System through Actual Operation)

  • 구경민;정영만;황유진;이재근;장세용;김인규;진심원;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1341-1346
    • /
    • 2008
  • This paper presents the heating performance of a water-to-refrigerant type ground source heat pump system (GSHP) installed in a school building. The evaluation of the heating performance has been conducted under the actual operating conditions of GSHP system in the winter. Ten units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. For analyzing the heating performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the heating capacity and the input power were evaluated for determining the heating performance of the GSHP system. The average heating coefficient of performance (COP) of the heat pump was found to be 5.1 at partial load of 46.9%, while the overall system COP was found to be 4.2.

  • PDF

지열원 히트펌프시스템의 실사용을 통한 난방성능연구 (Heating Performance of a Ground Source Heat Pump System through Actual Operation)

  • 구경민;정영만;황유진;이재근;장세용;김인규;진심원;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.788-793
    • /
    • 2008
  • This paper presents the heating performance of a water-to-refrigerant type ground source heat pump system (GSHP) installed in a school building. The evaluation of the heating performance has been conducted under the actual operating conditions of GSHP system in the winter. Ten units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. For analyzing the heating performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the heating capacity and the input power were evaluated for determining the heating performance of the GSHP system. The average heating coefficient of performance (COP) of the heat pump was found to be 5.1 at partial load of 46.9%, while the overall system COP was found to be 4.2.

  • PDF

익스팬션 앵커의 콘크리트 콘 파괴강도 평가 (Evaluation of Concrete Cone Breakout Strength of Expansion Anchors)

  • 김성용;김규석
    • 한국강구조학회 논문집
    • /
    • 제15권6호통권67호
    • /
    • pp.649-660
    • /
    • 2003
  • 본 논문은 비균열 무근콘크리트에 매입된 익스팬션 앵커의 인발내력을 평가하기 위한 실험적 연구이다. 앵커의 인발실험은 익스 팬션 앵커에 해당하는 고하중 앵커와 웨지 앵커를 대상으로 대상으로 삽입깊이, 콘크리트 강도 및 연단거리을 변수로 하여 실험을 수행하였다. 후시공 앵커의 설계식은 EOTA와 ACI 318-02 규준의 근거가 되는 CCD 방법이 제안되어 있다. 본 연구에서는 비균열 무근콘트리트에 매입된 익스팬션 앵커의 콘크리트 콘 파괴강도에 관한 설계식을 분석하였으며, 고하중 앵커와 웨지 앵커의 실험값을 CCD 방법의 예측값과 비교 평가하였다. 실험 결과, 비균열 무근콘크리트에 매입된 웨지 앵커의 콘크리트 콘 파괴 시 공칭강도의 계수는 CCD 방법에 근거하여 9.94임을 알 수 있었다. 고하중 앵커의 콘크리트 콘 파괴 시 공칭강도의 계수는 CCD 방법에 근거하여 11.50임을 알 수 있었다.