• Title/Summary/Keyword: Load Capability

Search Result 657, Processing Time 0.032 seconds

Evaluation for the Cooling Capability of Secondary Cooling Tower in HANARO (하나로 2차 냉각탑의 냉각능력 평가)

  • Park, Yong-Chul;Wu, Jong-Sup;Cho, Yeong-Gurb;Ryu, Jeong-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.345-350
    • /
    • 2000
  • The heat produced by the fission in the fuel of HANARO, 30 MW research reactor, is transferred from the primary cooling water to the secondary cooling water through heat exchangers, and the heat absorbed by the secondary cooling water is released into the atmosphere by the 33 MW cooling tower which is a mechanical induced draft and counter flow type. If the outlet temperature of cooling tower exceeds 33 of due to the loss of the cooling tower performance under reactor operation above $50\%$ of the full power, the reactor power should be reduced to half of the full power for safe operation. Therefore, the cooling capability of cooling tower should be maintained for the reactor to be normally operated. To predict the capability of cooling tower for full power reactor operation of 30 MW, the performance test of cooling tower was done at the reactor present power of 24 MW and the capability was respectively evaluated by characteristics and performance curves methods in accordance with the Code of Cooling Tower Institute of U.S.A. to confirm the reliability of evaluation. As a result, it was confirmed, through the results of each evaluation, that the cooling capability of cooling tower meets the design required heat load. Also, the equations of the performance and the characteristics curves of the cooling tower, based on the collected data during this performance test, was obtained for developing the calculation program to predict the cooling capability during reactor operation.

  • PDF

A Study of TRM and ATC Determination for Electricity Market Restructuring (전력산업 구조개편에 대비한 적정 TRM 및 ATC 결정에 관한 연구)

  • 이효상;최진규;신동준;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.129-134
    • /
    • 2004
  • The Available Transfer Capability (ATC) is defined as the measure of the transfer capability remaining in the physical transmission network for further commercial activity above already committed uses. The ATC determination s related with Total Transfer Capability (TTC) and two reliability margins-Transmission Reliability Capability (TRM) and Capacity Benefit Margin(CBM) The TRM is the component of ATC that accounts for uncertainties and safety margins. Also the TRM is the amount of transmission capability necessary to ensure that the interconnected network is secure under a reasonable range of uncertainties in system conditions. The CBM is the translation of generator capacity reserve margin determined by the Load Serving Entities. This paper describes a method for determining the TTC and TRM to calculate the ATC in the Bulk power system (HL II). TTC and TRM are calculated using Power Transfer Distribution Factor (PTDF). PTDF is implemented to find generation quantifies without violating system security and to identify the most limiting facilities in determining the network’s TTC. Reactive power is also considered to more accurate TTC calculation. TRM is calculated by alternative cases. CBM is calculated by LOLE. This paper compares ATC and TRM using suggested PTDF with using CPF. The method is illustrated using the IEEE 24 bus RTS (MRTS) in case study.

Calculation of Active Power Transfer Capability using Repeated Power Flow Program

  • Ham, Jung-Pil;Kim, Jung-Hoon;Lee, Byung-Ha;Won, Jong-Ryul
    • KIEE International Transactions on Power Engineering
    • /
    • v.12A no.1
    • /
    • pp.15-19
    • /
    • 2002
  • The power transfer capability is determined by the thermal, dynamic stability and voltage limits of the generation and transmission systems. The voltage stability depends on the reactive power limit and it affects the power transfer capability to a great extent. Then, in most load flow analysis, the reactive power limit is assumed as fixed, relatively different from the actual case. This paper proposes a method for determining the power transfer capability from a static voltage stability point of view using the IPLAN which is a high level language used with PSS/E program. The f-V curve for determining the power transfer capability is determined using Repeated Power Flow method. It Is assumed that the loads are constant and the generation powers change according to the merit order. The maximum reactive power limits are considered as varying similarly with the actual case and the effects of the varied maximum reactive power limits to the maximum power transfer capability are analyzed using a 5-bus power system and a 19-bus practical power system.

Optimal Distributed Computation with Communication Delays (통신지연이 있는 분산처리의 최적화)

  • Kim, Hyoung-Joong;Jee, Gyu-In;Lee, Jang-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.748-752
    • /
    • 1991
  • Tree network consisting of communicating processors is considered. The objective is to minimize the computation time by distributing the processing load to other nodes. The effect of the order of load distribution on the processing time is addressed. An algorithm which optimally determines the order of load distribution is developed. It is shown that the order depends only on the channel capacity between nodes but not on the computing capability of each node.

  • PDF

Composition and Operation of Direct Load Control(DLC) System for use of Demand Side (수용가용 직접부하제어시스템의 구성 및 운영)

  • Park J.C.;Choi M.G.;Lee Y.G.;Kim S.J.;Jeong B.H.;Choe G.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1260-1262
    • /
    • 2004
  • Direct Load Control(DLC) system is a load management program for stablization of electric power supply-demand. It is a series of acts limiting the demand of selected demand side at peak load or other time periods. Recently, power supply-demand instability due to dramatic increase in power usage such as summertime air-conditioning load has brought forecasts of decrease in power supply capability. Therefore heightening the load factor through systematic load management, in other words, Direct Load Control became necessary. By examining the composition and operation of the DLC system, this paper provides conceptional understanding of the DLC system and help in system research.

  • PDF

Advanced performance evaluation system for existing concrete bridges

  • Miyamoto, Ayaho;Emoto, Hisao;Asano, Hiroyoshi
    • Computers and Concrete
    • /
    • v.14 no.6
    • /
    • pp.727-743
    • /
    • 2014
  • The management of existing concrete bridges has become a major social concern in many developed countries due to the large number of bridges exhibiting signs of significant deterioration. This problem has increased the demand for effective maintenance and renewal planning. In order to implement an appropriate management procedure for a structure, a wide array of corrective strategies must be evaluated with respect to not only the condition state of each defect but also safety, economy and sustainability. This paper describes a new performance evaluation system for existing concrete bridges. The system evaluates performance based on load carrying capability and durability from the results of a visual inspection and specification data, and describes the necessity of maintenance. It categorizes all girders and slabs as either unsafe, severe deterioration, moderate deterioration, mild deterioration, or safe. The technique employs an expert system with an appropriate knowledge base in the evaluation. A characteristic feature of the system is the use of neural networks to evaluate the performance and facilitate refinement of the knowledge base. The neural network proposed in the present study has the capability to prevent an inference process and knowledge base from becoming a black box. It is very important that the system is capable of detailing how the performance is calculated since the road network represents a huge investment. The effectiveness of the neural network and machine learning method is verified by comparing diagnostic results by bridge experts.

A New Evaluation Methodology of Service Restoration Capability in Distribution Systems (배전계통 복구능력 평가방안 및 응용)

  • Im, Seong-Il;Jin, Bo-Geon;Lee, Seung-Jae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.7
    • /
    • pp.333-340
    • /
    • 2002
  • To secure a service continuity is one of the most important mission in the ower distribution system operation. In this paper the necessary and sufficient condition to guarantee 100% service restoration capability for any fault on the system is reported. An evaluation methodology of the restoration capability(or restorability) is developed based on the developed restoration conditions. Applications of the developed concept to the system operation in the normal and emergency states, that would enhance the supply reliability of the system are described. They include enhancement of restoration capability adapting to load change, identification of best open switch and supervised switch positions.

Analysis for Light Load Regulation of LLC Converter using Bode Plot (보드 선도를 이용한 LLC 컨버터의 경 부하 레귤레이션 특징 분석)

  • Yeon, Cheol-O;Moon, Gun-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.506-513
    • /
    • 2016
  • In general, LLC converters show great promise in applications that require high efficiency, especially under light load conditions. In particular, LLC converters feature wide gain capability with pulse-frequency modulation and zero voltage switching over entire load conditions. However, output voltage increases in light load conditions. In this study, Bode plot and impedance asymptotes analyses were conducted to obtain insights into the regulation characteristics of LLC converters under light load conditions. To improve the regulation characteristic of LLC converters, a new resonant tank with an additional capacitor is proposed. The design guideline for the proposed LLC converter is determined by the Bode plot and impedance asymptotes analyses. Therefore, the proposed LLC converter achieves the light load regulation while maintaining the advantages of typical LLC converters.

The Site Selection of 100MVA STATCOM for Voltage Stability Enhancement in Korean Metropolitan Area (수도권 전압안정도 향상을 위한 100MVA STATCOM 위치선정 연구)

  • Chang, Byung-Hoon;Kim, Soo-Yul;Han, Jeong-Yeol;Choi, Don-Keun;Song, Hwa-Chang;Lee, Byong-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1543-1548
    • /
    • 2007
  • This paper reports a study on determination of the adequate location of 100 MVA STATCOM regarding the transfer capability enhancement on the metropolitan interface as well as the economy in system operation. The base case in the study was established considering a scenario of the energy support to North Korea from the KEPCO (Korea Electric Power Corporation) system through a HVDC interconnection. In the base case, the energy support was approximately modeled with a load of 1500 MW, and by the load addition, the system was weakened in terms of voltage stability and transfer capability. After a thorough investigation on the case, the location of the STATCOM was decided to compensate the reactive deficit of the modified system and to maximize the operational benefit which can be estimated by FV analysis.