• Title/Summary/Keyword: Liver CT 검사

Search Result 109, Processing Time 0.022 seconds

The Effect of Attenuation Correction with CT on the Interpretation of Myocardial Perfusion SPECT: in Patients with Normal Coronary Angiogram (관상동맥조영술상 정상소견을 보인 환자에서 전산화단층촬영술(CT)를 이용한 감쇠보정이 심근관류 SPECT의 판독에 미치는 영향)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Kyu-Chang;Lee, Hyung-Woo;Hong, Geu-Ru;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.246-251
    • /
    • 2005
  • Purpose: There has been many reports for the effect of attenuation correction on myocardial perfusion SPECT. We studied the effect of attenuation correction with CT (computed tomography) in patients with normal coronary angiography. Materials and Methods: Fifteen patients with normal coronary artery on angiography and low likelihood of coronary artery disease were enrolled in this study (male: 6, female: 9, mean age: $58{\pm}8$ year). Myocardial perfusion SPECT was done with Millennium VG with Hawkeye device (GE, SPECT/CT camera). A visual analysis and polar map quantification (Emory tool box) was performed. In quantitative analysis, percent uptake of each myocardial wall on polar map (percent of maximal uptake) was compared between non-corrected (NC) and corrected (AC) images. Results: Visual analysis showed AC images led to an increase of uptake in the inferior wall, but decrease of uptake in the anterior wall, apex and septum. liver activity is also increased in AC images. In quantitative analysis, the percent uptake is decreased in the anterior wall, apex and septum, but increased in the inferior wall. It is helpful to interpret the images in the inferior wall after AC, but difficult in the apex and anterior wall after AC. Conclusion: AC is helpful in the inferior wall. But in the apex or anterior wall, AC must be carefully applied to normal perfused myocardium.

The Clinical Usefulness of NP-59 Scintigraphy in Adrenal Cortical Diseases (NP-59 부신 신티그라피의 임상적 유용성에 관한 연구)

  • Kim, Duk-Kyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.108-115
    • /
    • 1997
  • $^{131}I-6{\beta}$-iodomethyl-19-norcholesterol(NP-59) has an advantage to assess adrenal dysfunction caused by adrenal cortical disorders. The aim of this study is to evaluate the clinical usefulness of NP-59 scintigraphy in each adrenal disease. Ten patients who did eleven NP-59 adrenal scintigraphies at Dong-A University Hospital from March 1990 to December 1996 were selected as the subject. Among the subject there were 5 cases of Cushing's syndrome, 2 cases of incidentaloma, 1 case of metastatic adrenal tumor, liver cirrhosis with hirsutism and hypertension respectively. Among 5 cases of Cushing's syndrome, there were 2 cases of Cushing's disease, 2 cases of adrenal adenoma and 1 case of adrenal carcinoma. There are no disagreement between clinical diagnosis and scan finding in Cushing's syndrome. In 2 incidentaloma cases, even though one is interpretated as a functioning tumor, both of 2 cases could avoid unnecessary biopsy according to scintigraphy result. One case of hirsutism, clinically adrenal originated, revealed the normal scintigraphic finding after dexamethasone suppression scan. It could suggest that the etiology of hirsutism was extra-adrenal origin. One case of hypertension took the study to exclude the possibility of primary aldosteronism. Normal suppression scan finding revealed that primary aldosteronism did not exist in this case. In conclusion, NP-59 scintigraphy was very useful in diagnosis and differential diagnosis of Cushing's syndrome and it could avoid unnecessary biopsy in the incidental adrenal tumor.

  • PDF

Chronic Hereditary Tyrosinemia Type I with Novel Mutation in FAH Gene (FAH gene novel mutation을 가진 만성형 Hereditary tyrosinemia 1형)

  • Yang, Sungmin;Choi, Hyo Won;Kang, Yun Koo;Lee, Jin-Sung;Namgoong, Mee Kyung
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.20 no.2
    • /
    • pp.55-62
    • /
    • 2020
  • A 22-month-old girl who had taken iron supplements due to iron deficiency anemia, presented bloody mucoid stool for one month. She had a bruise at the right periorbital area due to minor trauma and hepatosplenomegaly. Laboratory studies showed anemia, thrombocytopenia, elevated alkaline phosphatase (ALP), hypophosphatemia, decreased haptoglobin, hypocomplementemia, negative direct/indirect Coomb's test, normal vitamin D3 level and high PTHi. Wrist x-ray showed no signs of rickets. The abdominal ultrasound showed only accessory spleen. Tandem mass spectrometry was normal. During follow up, bloody stool regressed after seven days of withdrawal of iron supplement and cow milk, and the total CO2 level had been within 15-20 mEq/L with normal anion gap. NGS (next generation sequencing) panel test for evaluation of renal tubular acidosis showed negative results. After low dose steroid and vitamin D supplements under the impression of hypocomplementemic vasculitis, thrombocytopenia, C3/C4, decreased haptoglobin, and elevated ALP level became normal. At 57 months of age, laboratory findings showed elevated liver enzyme, ALP and gamma-glutamyl transferase again. And liver cirrhosis with splenomegaly and diffuse renal disease were reported with abdomen CT scan. Liver biopsy reported macro- and micronodular cirrhosis. Urine organic acid profile showed elevated succinylacetone level. Whole exome sequencing revealed novel compound heterozygous mutations (NM_00137.2:c.107T>C, NM_00137, 2:c.614T>C) in FAH gene and confirmed by Sanger sequencing. Consequently, the patient was diagnosed as chronic hereditary tyrosinemia type I. She started low phenylalanine/tyrosine diet and nitisinone treatment. Our case had presented symptoms very slowly, which is the first case of chronic tyrosinemia type I in South Korea.

The Evaluation of Usefulness of 99Mo-99mTc Generator Using(n,γ)99Mo Developed by Korea Atomic Energy Research ((n,γ)99Mo를 이용한 99Mo-99mTc발생기의 유용성 평가)

  • Seo, Han Kyung;Kim, Jeong Ho;Shim, Cheol Min;Kim, Byung Cheol;Choi, Do Cheol;Gwon, Yong Ju;Park, Yung Sun;Kim, Dong Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.48-52
    • /
    • 2013
  • Purpose: The Molybdenum which is the raw material of $^{99}Mo-^{99m}Tc$ generator is produced from the nuclear reactor. However, output has dwindled as the two nuclear reactors supplying the bulk of radioactive material-one in Chalk River, Ontario and the other in Petten, the Netherlands-have been closed for repairs or maintenance. This resulted in the enhancement of its price. So $^{99}Mo-^{99m}Tc$ generator using$(n,{\gamma})^{99}Mo$ is developed by Korea Atomic Energy Research Institute (KAERI). Medicinal availability of this generator is evaluated in this study. Materials and Methods: The radioactivity of $^{99m}Tc$ eluted in generator 1, 2 and 3 unit developed by KAERI was measured. The quality control test of generator such as appearance test, pH test, LAL test, sterility test, chemical impurity (Al) test and radiochemical purity test were performed. Planar and SPECT/CT image sof SD rat (6 weeks, Female) at 2 hr after injection of $^{99m}Tc-HDP$ (hydroxymethylenediphosphonate) (TechneScan HDP, Malinckrodt Medical, Dutch) and $^{99m}Tc-DPD$ (diphosphono-1, 2-propanedicarboxylicacid) (TECEOS, CIS bio international, France) which were labeled with $^{99m}Tc$ eluted in KAERI and commercial generator (40.5 GBq, Malinckrodt Medical, Dutch) using SPECT/CT camera (Symbia, Siemense, Germany) were obtained respectively. Results: The mean radioactivity of $^{99m}Tc$ elution generator 1unit was 4.18 GBq (113 mCi), generator 2 unit was 4.73 GBq (128 mCi) and generator 3 unit was 3.33 GBq (90 mCi). All quality control tests were within normal limit except pyrogentest. Pyrogen test was positive. Planar and SPECT/CT images of rat injected $^{99m}Tc-HDP$ which was labeled with $^{99m}Tc$ eluted in commercial generator show increased uptake in bone, stomach and bowl. Planar images show increased uptake in liver and bone in case of $^{99m}Tc-DPD$. However, images of rat injected $^{99m}Tc-HDP$ and $^{99m}Tc-DPD$ which were labelled $^{99m}Tc$ eluted in KAERI generator show increased uptake in bone, liver and spleen. Conclusion: If shortcoming is removed such as pyrogen and liver appearance, domestic role as an alternative generator is thought to be able to fill and to secure the national medical service by supplying $^{99m}Tc$ when the supply of $^{99m}Tc$ be comes short.

  • PDF

Dorsal Cavoatrial Bypass for Congenital Interruption of IVC (선천성 하대정맥 중단 환자의 후방 대정맥-우심방 우회 수술 치료 증례)

  • Choe, Ju-Won;Hong, Joon-Hwa;Sohn, Dong-Suep;Cho, Dai-Yun
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.525-528
    • /
    • 2010
  • Congenital interruption of the inferior vena cava (IVC) can lead to secondary hepatic congestion, portal hypertension, and liver cirrhosis. A 49-year-old woman was admitted to the gynecology department with symptoms of menorrhalgia, known uterine myoma, and anemia. Abdominal computed tomography (CT) and venography performed at our hospital revealed congenital interruption of the IVC. The patient underwent retrohepatic cavoatrial bypass surgery with a polytetrafluoroethylene (PTFE) 16-mm ringed graft via posterolateral thoracotomy, and recovered without major complications. A retroperitoneal approach via posterolateral thoracotomy provides appropriate visualization during dorsal cavoatrial bypass in treating patients with congenital interruption of IVC.

Atypical Manifestation of Primary Hepatocellular Carcinoma and Hepatic Malignancy Mimicking Lesions (원발성 간세포암의 비특이적 영상 소견 및 간암으로 오인될 수 있는 병변에 대한 영상의학적 고찰)

  • Jiyoung Yoon;So Hyun Park;Su Joa Ahn;Young Sup Shim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.4
    • /
    • pp.808-829
    • /
    • 2022
  • Hepatocellular carcinoma (HCC) can be diagnosed noninvasively on multiphasic CT and MRI based on its distinctive imaging findings. These features include arterial phase hyperenhancement and washout on portal or delayed phase images. However, radiologists face significant diagnostic challenges because some HCCs exhibit atypical imaging characteristics. In addition to many HCC-mimicking lesions, such as arterioportal shunts, combined HCC-cholangiocarcinoma, intrahepatic cholangiocarcinoma, and hemangioma present a challenge for radiologists in actual clinical practice. The ability to distinguish HCCs from mimickers on initial imaging examinations is crucial for appropriate management and treatment decisions. Therefore, this pictorial review presents the imaging findings of atypical HCCs and HCCs mimicking malignant and benign lesions and discusses important clues that may help narrow down the differential diagnosis.

Development of Image Quality Measurement Method of Coronary Angiography Using Image Analysis Program (영상 분석 프로그램을 이용한 관상동맥 혈관 조영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.111-120
    • /
    • 2020
  • Research should be actively conducted for the ability of X-ray equipment and Retrospective image analysis of X-ray equipment used in hospitals. Retrospective image analysis of X-ray machines, CT and MRI of radiology and medical equipment has been actively conducted. However, image quality measurement using angiography equipment of angiography room is mostly measured with phantom, and image quality measurement on image after being taken by actual patient is insufficient and researches on accurate image quality measurement method are remarkable. It is in short supply. Therefore, through this study, the researcher devised a method to measure the image quality of the acquired image after coronary angiography, and to provide a high quality image to the operator. The equipment and programs used were angiographic examination equipment (Axiom Artis Zee Ceiling) and Image J program. Subjects were images automatically saved in PACS program after coronary angiography.For image quality measurement, selected the AP Caudal 30° image that show the LCA vessel well and the LAO 30° image that show the RCA vessel well during the coronary angiography. In order to measure the background and ROI of the selected image by selecting an image, a criterion on how to find and measure a section where the overlap of the shadow, such as blood vessel, liver and lung is minimized, is presented. In conclusion, there is no exact standard for analyzing an image quality measurement method of angiography image. Therefore, in order to provide quality images to the practistioners, not only the technicians of the equipment but also the users who actually use them should become researchers and conduct research on image quality measurement in various ways. Thus, it is expected to provide excellent images to patients.

A Simulation Study on Image Quality of Virtual Monochromatic Image using Dual-energy Method (이중에너지 방법을 이용한 가상 단색 영상의 화질 시뮬레이션 연구)

  • Son, Ki-Hong;Lee, Soo-Yeul;Kim, Dae-Hong;Chung, Myung-Ae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.553-558
    • /
    • 2022
  • The purpose of this work was a simulation study to evaluate the virtual monochromatic (VM) image quality of blood vessels compared to the monochromatic image. Dual-energy images were obtained based on the linear attenuation coefficients of five materials at 50 keV and 80 keV at low- and high-energies, respectively. A weighting factor is required to synthesize the VM image, and the liver and bone were used as basis materials to obtain the weighting factor. VM images were synthesized at energies ranging from 30 keV to 100 keV. Image quality was evaluated by Contrast to noise ratio (CNR) and noise by setting calcium and contrast medium as signals and blood as background. According to the results, the energies with the maximum CNR were 50 keV and 60 keV for calcium and contrast medium, respectively. The energies showing the minimum noise were 70 keV, 70 keV, and 60 keV in calcium, iodine contrast medium, and blood, respectively. The VM image can contribute to the improvement of diagnostic performance in CT examination because it can implement an image at the optimal energy that minimize noise and maximize CNR.

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Protective Effect of Saengshik Supplementation on Lead Induced Toxicity in Rats (생식의 섭취가 납중독 흰쥐의 피해 경감에 미치는 영향에 관한 연구)

  • Oh, Young-Joo;Kim, Jae-Min;Song, Si-Wan;Ha, Hyo-Cheol;Kim, Hyun-Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.7
    • /
    • pp.959-967
    • /
    • 2005
  • Lead is a ubiquitous environmental and industrial pollutant that causes a major health concerns. It is known to induce a broad range of physiological, biochemical, and behavioral dysfunctions in laboratory and humans, including hematopoietic system, kidneys, liver, and reproductive system. This study was conducted to investigate the effect of Saengshik supplementation on the lead-induced toxicity in rats. Five week old male Sprague­Dawley rats were randomly assigned to five groups for six weeks as followings: control group (CT), lead acetate treated group (PT), and lead acetate groups administered with three different dosages of Saengshik $(SI2.5-12.5\%,\;S25-25\%,\;and\;S50-50\%).$ Lead acetate (12 mg/rat) was intragastrically administered daily for 6 weeks. The results were summarized as follows; Weight gain and food efficiency ratio were significantly lower (p<0.05) in lead administered group compared with those of the control group. Also, significant lead-induced alteration in blood hemoglobin (HGB), hematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and reticulocyte distribution width (RDW) were observed. In the liver of lead-exposed animals, there was an increase in the lipid peroxidation (MDA) and the level of glutathione (GSH), but superoxiede dismutase (SOD) activity did not change. Lead-exposed animals with $25\%\;and\;50\%$ Saengshik supplementation showed marked improvements in the values of MCH, MCV, and RDW. Also, the level of HCT was significantly increased by $50\%$ Saengshik supplementation. The levels of liver MDA in $12.5\%\;and\;50\%$ Saengshik administered groups and GSH level in $50\%$ Saengshik administered group were significantly decreased compared to the lead administered group. Also, hepatic SOD activity tended to increase in the presence of Saengshik supplementation. Furthermore, the accumulation of lead in liver and kidney was reduced by presence of Saneghshik supplementation. Liver lead concentration was significantly reduced by both $25\%\;and\;50\%$ Saengshik supplementations and kidney lead concentration was significantly reduced by the $25\%$ Saengshik supplementation. These results show that Saengshik may have a protective effect against lead intoxication but the mechanism of their effects remains unclear.