• Title/Summary/Keyword: Lithium-Ion Battery

Search Result 956, Processing Time 0.024 seconds

Lithium-ion Stationary Battery Capacity Sizing Formula for the Establishment of Industrial Design Standard

  • Chang, Choong-koo;Sulley, Mumuni
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2561-2567
    • /
    • 2018
  • The extension of DC battery backup time in the DC power supply system of nuclear power plants (NPPs) remains a challenge. The lead-acid battery is the most popular at present. And it is generally the most popular energy storage device. However, extension of backup time requires too much space. The lithium-ion battery has high energy density and advanced gravimetric and volumetric properties. The aim of this paper is development of the sizing formula of stationary lithium-ion batteries. The ongoing research activities and related industrial standards for stationary lithium-ion batteries are reviewed. Then, the lithium-ion battery sizing calculation formular is proposed for the establishment of industrial design standard which is essential for the design of stationary batteries of nuclear power plants. An example of calculating the lithium-ion battery capacity for a medium voltage UPS is presented.

Exposure Assessment Study on Lithium-Ion Battery Fire in Explosion Test Room in Battery Testing Facility

  • Mi Sung Jo;Hoi Pin Kim;Boo Wook Kim;Richard C. Pleus;Elaine M. Faustman;Il Je Yu
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.114-117
    • /
    • 2024
  • A lithium-ion battery is a rechargeable battery that uses the reversible reduction of lithium ions to store energy and is the predominant battery type in many industrial and consumer electronics. The lithium-ion batteries are essential to ensure they operate safely. We conducted an exposure assessment five days after a fire in a battery-testing facility. We assessed some of the potentially hazardous materials after a lithium-ion battery fire.We sampled total suspended particles, hydrogen fluoride, and lithium with real-time monitoring of particulate matter (PM) 1, 2.5, and 10 micrometers (㎛). The area sampling results indicated that primary potential hazardous materials such as dust, hydrogen fluoride, and lithium were below the recommended limits suggested by the Korean Ministry of Labor and the American Conference of Governmental Industrial Hygienists Threshold Limit Values. Based on our assessment, workers were allowed to return to work.

Space Qualification of Small Satellite Li-ion Battery System for the Secured Reliability (소형인공위성용 리튬이온 배터리시스템의 신뢰성 확보을 위한 우주인증시험)

  • Park, Kyung-Hwa;Yi, Kang-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.4
    • /
    • pp.351-359
    • /
    • 2014
  • This paper introduces the lithium ion battery system for LEO(Low Earth Orbit) small satellites. This study proves the reliability of lithium ion batteries applying to the space application. The specifications for lithium ion battery unit are proposed to supply power to the satellite and the overall mechanical design including structural simulation to confirm the reliability of the lithium ion BMS(Battery Management System) under the space environment and launching conditions. The results of structural simulation, functional tests, and space environmental tests show the lithium ion battery system is space qualified. Space qualification of the small satellite battery system to secure reliability of BMS and lithium ion batteries lend credibility for using lithium ion batteries in space application.

Development of a new Li-Ion Pack-Battery for improving the electrical properties (전기적인 특성향상을 위한 리튬이온전지팩 개발)

  • Gang, Young-Gu;Kweon, Hyun-Kyu;Seo, Myung-Su;Park, Chang-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.2
    • /
    • pp.90-95
    • /
    • 2009
  • This paper presents a new lithium ion unit-cell and pack battery by using a new formulation ratio of material. The three types of formulation ratio for the unit-cell were used. The life cycle and basic properties of the lithium ion unit-cell$({\Psi}18{\times}65(mm))$ about one of them were acquired by the charge-discharge experiment. The nominal voltage, nominal capacity and cycle life output of the lithium ion unit-cell is respectively 3.7V, 2.4Ah, and above 500cycle. Pack type lithium ion battery has the size of $29.5{\times}73.5{\times}115(mm)$ and the weight of 300g. As the results, the weight and bulk of lithium ion battery used to a safety lamp were decreased to 1/4 and 1/7. In addition, the comparison of the new lithium ion battery and lead storge battery for confirming the effectiveness of the new lithium ion battery have been performed.

  • PDF

Improved Low-temperature Performance of Lithium Secondary Battery Using Energy Circulating Operation (리튬 이차전지의 저온 성능 개선을 위한 에너지 순환 작동 연구)

  • Yoon, Hyun-Ki;Ha, Sang-Hyeon;Lee, Jaein
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.421-428
    • /
    • 2021
  • Lithium-ion secondary batteries exhibit advantageous characteristics such as high voltage, high energy density, and long life, allowing them to be widely used in both military and daily life. However, the lithium-ion secondary battery does have its limitation; for example, the output power and capacity are readily decreased due to the increased internal impedance during discharging at a lower temperature (-32℃, military requirement). Also, during charging at a lower temperature, lithium dendrite growth is accelerated at the anode, thereby decreasing the battery capacity and life as well. This paper describes a study that involves increasing the internal temperature of lithium-ion secondary battery by energy circulation operation in a low-temperature environment. The energy circulation operation allows the lithium-ion secondary battery to alternately charge and discharge, while the internal resistance of lithium-ion battery acts as a heating element to raise its own temperature. Therefore, the energy circulation operation method and device were newly designed based on the electrochemical impedance spectroscopy of the lithium-ion secondary battery to mediate the battery performance at a lower temperature. Through the energy circulation operation of lithium ion secondary battery, as a result of the heat generated from internal resistance in an extremely low-temperature environment, the temperature of the lithium-ion secondary battery increased by more than 20℃ within 10 minutes and showed a 75% discharging capacity compared with that at room temperature.

Improvement of Available Battery Capacity in Electric Vehicles

  • Liu, Yow-Chyi
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.497-506
    • /
    • 2013
  • This paper proposes a new method to improve the available battery capacity in electric vehicles by connecting lead-acid batteries with lithium-ion battery in parallel to supply power. In addition, this method combines the discharge characteristics of batteries to improve their efficiency and lower their cost for electric vehicles. A lithium-ion battery set is used to connect with N sets of lead-acid batteries in parallel. The lead-acid battery supplies the initial power. When the lead-acid battery is discharged by the load current until its output voltage drops to the cut-off voltage, the power management unit controls the lead-acid battery and changes it to discharge continuously with a small current. This discharge can be achieved by connecting the lead-acid battery to a lithium-ion battery in parallel to supply the load power or to discharge its current to another lead-acid or lithium-ion battery. Experimental results demonstrates that the available capacity can be improved by up to 30% of the rated capacity of the lead-acid batteries.

Lifetime Management Method of Lithium-ion battery for Energy Storage System

  • Won, Il-Kuen;Choo, Kyoung-Min;Lee, Soon-Ryung;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1173-1184
    • /
    • 2018
  • The lifetime of a lithium-ion battery is one of the most important issues of the energy storage system (ESS) because of its stable and reliable operation. In this paper, the lifetime management method of the lithium-ion battery for energy storage system is proposed. The lifetime of the lithium-ion battery varies, depending on the power usage, operation condition, and, especially the selected depth of discharge (DOD). The proposed method estimates the total lifetime of the lithium-ion battery by calculating the total transferable energy corresponding to the selected DOD and achievable cycle (ACC) data. It is also demonstrated that the battery model can obtain state of charge (SOC) corresponding to the ESS operation simultaneously. The simulation results are presented performing the proposed lifetime management method. Also, the total revenue and entire lifetime prediction of a lithium-ion battery of ESS are presented considering the DOD, operation and various condition for the nations of USA and Korea using the proposed method.

Data-Driven Approach for Lithium-Ion Battery Remaining Useful Life Prediction: A Literature Review

  • Luon Tran Van;Lam Tran Ha;Deokjai Choi
    • Smart Media Journal
    • /
    • v.11 no.11
    • /
    • pp.63-74
    • /
    • 2022
  • Nowadays, lithium-ion battery has become more popular around the world. Knowing when batteries reach their end of life (EOL) is crucial. Accurately predicting the remaining useful life (RUL) of lithium-ion batteries is needed for battery health management systems and to avoid unexpected accidents. It gives information about the battery status and when we should replace the battery. With the rapid growth of machine learning and deep learning, data-driven approaches are proposed to address this problem. Extracting aging information from battery charge/discharge records, including voltage, current, and temperature, can determine the battery state and predict battery RUL. In this work, we first outlined the charging and discharging processes of lithium-ion batteries. We then summarize the proposed techniques and achievements in all published data-driven RUL prediction studies. From that, we give a discussion about the accomplishments and remaining works with the corresponding challenges in order to provide a direction for further research in this area.

The Simulation of Single Phase Multi-Level Converter which can control the SOC of Lithium-Ion Battery Units (리튬이온 배터리의 SOC 제어가 가능한 단상 멀티레벨 컨버터 시뮬레이션)

  • Kim, Jae-Hong;Kim, Eel-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.122-128
    • /
    • 2011
  • This paper proposes a new control scheme of lithium ion battery units based on single phase multi-level converter. In the DC/AC converter applications using battery storage system, it is necessary to control the balancing voltage of individual battery units for high efficiency utilization. Using the proposed control scheme, the DC/AC single phase converter system is applied. To verify the effectiveness of the proposed control scheme, computer simulation is accomplished. In the computer simulation, lithium-ion battery units and single phase multi-level converter system are modeled and carried out using Psim simulation program. It will be helpful for design and applications of energy storage system with lithium-ion battery.

An Experimental Study on the Charging/Discharging Characteristics and Safety of Lithium-Ion Battery System for Submarine Propulsion (잠수함 추진용 리튬이온전지 충방전 특성 및 안전성 확보를 위한 실험적 연구)

  • Kim, Beomseog;Sohn, Seung hyun;Kang, Seokjoong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.4
    • /
    • pp.225-233
    • /
    • 2021
  • Conventional submarine propulsion batteries have mainly used lead acid batteries, which have proved relatively safe, but in recent years, research on mounting lithium-ion batteries to improve the underwater operation capability of submarines is underway in advanced countries such as Japan. Korea has world-class technology in the development of electric vehicles and lithium-ion batteries for energy storage, but fire safety accidents continue to occur in electric vehicles and energy storage lithium-ion batteries. In order to mount the lithium-ion battery in a submarine, it is necessary to check the safety as well as whether the performance is improved compared to the lead acid battery. Through the charge/discharge experiment of this lithium-ion battery module unit, it was possible to measure how much performance was improved compared to the lead acid battery. Safety tests were conducted on the lithium-ion battery module assuming that it was mounted on a submarine, and it was confirmed that safety was secured when applied to a submarine. Since many modules are mounted on actual submarines, it has been confirmed that it can be applied to submarine systems by simulating charge/discharge characteristics through Hardware-in-the Loop(HILS). Through the results of this study, the application of lithium-ion batteries to submarines is expected to significantly improve the sustainability of underwater operations.