• 제목/요약/키워드: Liquid-vapor separator

검색결과 16건 처리시간 0.024초

혼합냉매의 성분비 조절을 통한 열펌프의 용량조절 (Capacity Modulation of a Heat Pump System by Changing the Composition of Refrigerant Mixtures)

  • 김민성;김민수;김용찬
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.258-266
    • /
    • 2000
  • Experimental investigation and cycle simulation of a capacity modulation of a heat pump system using a hydrofluorocarbon (HFC) refrigerant mixture, R32/134a as an alternative to R22, have been done. In the cycle simulation, the refrigeration system was operated by assigning the temperatures of the external heat transfer fluids with the heat exchangers generalized by an average effective temperature difference. Heating capacity, cooling capacity, and coefficient of performance (COP) of the system were investigated at several operating conditions. Experimental apparatus which had a refrigeration part and a composition changing part was built, and the performance of the heat pump system filled with R32/134a mixture was investigated. A gas-liquid separator was used in the experiment to change the composition by collecting the vapor and the liquid Phase separately, The mass fraction of the charged refrigerant in the heat pump system was 40/60 and 70/30 by weight percentage. The composition of the refrigerant with initial composition of 40/60 varied from 29/71 to 41/59 in the refrigeration cycle. For the refrigerant with initial composition of 70/30, the composition varied from 65/35 to 75/25.

  • PDF

LNG선박용 BOG 부분재액화 시스템 특성 연구 (Characteristics of boil-off-gas partial re-liquefaction systems in LNG ships)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.174-179
    • /
    • 2016
  • 해양의 환경오염을 줄이기 위하여 LNG 운송선박, 벙커링 선박 및 LNG를 연료로 추진되는 선박의 건조가 증가하고 있다. 이러한 LNG 선박의 저장탱크들은 외부로부터의 열유입으로 증발가스가 지속적으로 발생하고 있으며, 최근 국내 조선사들은 이 BOG를 재액화하여 회수하는 장치를 개발하여 보급하고 있다. 본 연구에서는 부분재액화 처리장치들의 이론적 최대 재액화 수율을 분석하고 재액화 수율에 미치는 영향 인자들을 비교하였다. 해석결과, BOG와 플래시 가스가 보유한 냉열을 열교환으로 간접 이용하는 부분재액화 처리장치는 최대 48.7%가 되었으며, BOG와 플래시 가스가 혼합 합체되어 냉열이 직접 이용되는 부분재액화 처리장치는 최대 41%로 해석되었다. 또한 액체 수율에 크게 영향을 미치는 인자로는 열교환기의 효율로 열교환기의 성능과 단열이 매우 중요한 것임을 알 수 있다.

재열기를 사용한 고성능 VI 사이클 열펌프의 난방 성능 특성에 관한 연구 (A Study on the Characteristics of Heating Performance of High-Performance Heat Pump with VI cycle using Re-Heater)

  • 이진국;최광환
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.69-75
    • /
    • 2015
  • In this study, the characteristics of heating performance of a high-performance air-cooled heat pump with vapor-injection(VI) cycle using re-heater was investigated experimentally. Devices used in the experiment is consist of a VI compressor, condenser, oil separator, refrigerant (economizer outlet refrigerant) re-heater, economizer, evaporator. And R410A was used as a working fluid. The experiment was conducted with two cycles(cycles A and B) for investigating heating performance. In case of cycle B, heat exchange was conducted by re-heater between outlet refrigerant of compressor and suction refrigerant of the VI system(Fig.1, re-heater). But the re-heater was not used in case of cycle A. As a result of this experiment, discharge temperature of refrigerator in compressor was shown higher value, when the cycle B was conducted, because of the heat exchange between suction refrigerant of VI cycle and outlet refrigerant of compressor in the re-heater than cycle A that was not use re-heater. it means that liquid hammer and the decrement of heating performance can be decreased by using re-heater. Also, Heating coefficient of performance(COPh) was shown about 2.98 in Cycle B which was 4% higher than Cycle A and from these results, It was confirmed that the improvement of the heating performance of heat pump with VI cycle can be achieved by applying re-heater.

대기입자의 원소성분 배출특성연구를 위한 반-연속식 입자채취시스템 적용 (Application of Semi-continuous Ambient Aerosol Collection System for Elemental Analysis)

  • 박승식;고재민;이동수
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.39-51
    • /
    • 2012
  • Aerosol slurry samples were collected in 60-min interval using Korean Semi-continuous Elements in Aerosol Sampler (KSEAS) between May 19 and June 6, 2010 at an urban site of Gwangju. The $PM_{2.5}$ samples were collected with a flow rate of 16.7 L/min and particles are grown by condensation of water vapor in a condenser maintained at ${\sim}5^{\circ}C$ after saturation by direct injection of steam. The resulting droplets are collected in a liquid slurry with a airdroplet separator. Concentrations of 16 elements (Al, Fe, Mn, Ca, K, Cu, Zn, Pb, Cd, Cr, Ti, V, Ni, Co, As, Se) in the collected slurry samples were determined off-line by ICP-MS. KSEAS sample analysis encompassed the sampling periods for which 24-hr average elemental species concentrations were calculated for comparison with those derived from 24-hr integrated filter samples. Relationship between elemental species measured by two methods indicated high correlation coefficients (r), mostly greater than r of 0.80. However, we note that concentrations of Al, K, Ca, Mn, and Fe, which are often associated with crustal elemental particles, in the KSEAS samples, were substantially lower (1.4~11 times) than those found in the typical filter-based samples. This discrepancy is probably due to difficulties in transferring insoluble dust particles to the collection vials in the KSEAS. Temporal profiles of elemental concentrations indicate that some transient events in their concentrations are observed over the sampling periods. For the elemental species studied, atmospheric concentrations during the transient events increased by factors of 4 in Mn~80 in Zn, compared to their background levels. Principle component analyses were applied to the hourly KSEAS data sets to identify sources affecting the concentrations of the metal constituents observed. In this study, we conclude that hourly measurements for particle-bound elemental constituents were extremely useful for revealing the short-term variability in their concentrations and developing insights into their sources.

천연혼합냉매를 이용한 압축/흡수식 고온히트펌프의 실험적 연구 (Experimental Study on Compression/Absorption High-Temperature Hybrid Heat Pump with Natural Refrigerant Mixture)

  • 김지영;박성룡;백영진;장기창;나호상;김민성;김용찬
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1367-1373
    • /
    • 2011
  • 본 연구에서는 천연냉매를 적용한 압축/흡수식 하이브리드 고온제조 히트펌프를 실험적으로 연구한 결과를 제시하였다. 압축/흡수식 히트펌프는 기존의 증기압축 히트펌프에 비해 고온영역을 포함한 넓은 생산온도범위, 높은 승온기능, 다양한 용량 제어방법 등 여러가지 장점을 가지고 있다. 제작된 하이브리드 히트펌프는 현재 실제 산업현장에 적용하기 이전의 초기 시제품 단계로 실험실에 설치하여 운전하였으며, 주요 구성부품으로는 이단압축기, 흡수기, 재생기, 과열냉각기, 용액 열교환기, 용액펌프, 기액분리기/정류기 등이다. 성능실험에서 $50^{\circ}C$의 열원을 고온 및 저온열원으로 사용한 결과 $90^{\circ}C$ 이상의 고온수 토출과 10 kW급의 난방 용량을 얻을 수 있었다. 혼합냉매의 성분비 변화에 따른 압축기/펌프 유량의 순환비 변화 및 다양한 성능변화를 실험적으로 관찰하였으며, 시스템의 효율과 용량에 있어 최적 성분비가 존재함을 확인하였다.

NH3/H2O 혼합냉매를 사용한 압축/흡수식 히트펌프 시스템의 흡수기 최적화에 관한 실험적 연구 (Experimental Study on Optimization of Absorber Configuration in Compression/Absorption Heat Pump with NH3/H2O Mixture)

  • 김지영;김민성;백영진;박성룡;장기창;나호상;김용찬
    • 대한기계학회논문집B
    • /
    • 제35권3호
    • /
    • pp.229-235
    • /
    • 2011
  • 본 연구는 암모니아/물 혼합냉매를 이용한 압축/흡수식하이브리드 히트펌프 개발에 관한 연구이다. 히트펌프 사이클은 증기압축식과흡수식을 혼합한 개념으로 이단압축기, 흡수기, 재생기, 과열냉각기, 용액열교환기(SHX), 용액펌프, 정류기, 기액분리기 등으로 구성되어 있다. 압축/흡수식 히트펌프는 상변화 열교환과정에서 높은 온도구배를 이용하여 $90^{\circ}C$ 이상의 고온을 제조하기 위한 목적으로 고안되었다. 특히 흡수기에서의 응축과정은 비열변화로 인하여 온도변화에 비선형성이 뚜렷한데, 시스템 성능 최적화를 위하여는 흡수기의 설계가 중요하다. 본 연구에서는 다수의 판형열교환기로 흡수기를 구성하였는데 열교환기의 용량, 형태, 배치에 따른 성능특성을 실험적으로 관찰하였다.