• Title/Summary/Keyword: Liquid ventilation

Search Result 44, Processing Time 0.026 seconds

Wet Chemical Process for Improving Air Quality in Semiconductor Manufacturing Process (반도체 생산공정의 대기질 개선을 위한 복합 대기오염물의 습식화학 제거공정)

  • Jun, Chang-Sung;Kim, Hak-Ju;Park, Young-Moo;Lee, Dae-Won;Ham, Dong-Suk;Jeon, Sang-Moon;Lee, Kwan-Young
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.109-114
    • /
    • 2007
  • In this study, we performed basic researches to develop wet purification system for improving air qualities of ventilation in semiconductor manufacturing process. Using 0.5 M aqueous solution of $KMnO_4$, 50 ppm of $NH_3$, SOx and NOx were reduced to 99% successfully. However, the removal of $O_3$ was limited to $22{\sim}30%$ for all the tested chemical solutionsincluding $KMnO_4$. Therefore, adoption of a dry ozone filter is necessary to reduce $O_3$ below a satisfactory level. For all the chemical solutions tested, NOx removal efficiency increased as NOx was mixed with $O_3$. As chemical solution was sprayed using water spraying system equipped with air atomizing type nozzle, the removal efficiencies of gaseous pollutants increased due to the increase of gas-liquid interfacial area.

  • PDF

Development of the Hospital Foodservice Facility Evaluation tools based on the General HACCP-based Sanitation Standards and Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설ㆍ설비 위생관리 점검도구 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.3
    • /
    • pp.339-353
    • /
    • 2003
  • The rapid increase in food borne illness outbreaks in Korea has been one of the major threats to the Nation's Health. Foodservice establishments have been identified as the major place for these outbreaks, mainly due to the lack of sanitary management and sanitary facility management practices. The purposes of the study were to develop hospital foodservice facility evaluation tools, based on the general HACCP-based standards and guidelines, for hospital food service establishments, to ensure the safety of these foodservices and to reduce the risk of food home illness. The scope of this study included: 1) an assessment of the current foodservice sanitation practices and managements for 6 general hospitals, with more than 400 beds, and 3 general hospitals, with less than 400 beds; 2) the development of foodservice establishments sanitation evaluation tools and sanitation standards, based on the HACCP system. The survey data showed varied results between the hospitals surveyed. Most of the hospital foodservice operations had many problems with ventilation and the plumbing. The total dimensional mean scores for the hospitals with more than 400 beds and less than 400 beds were 31.5 and 27.0, respectively. The highest dimension scores were for the water supply facility and lighting, with the lowest for insect and rodent control and toxic materials management. The levels of the mean scores were very low, especially for the general hospitals with less than 400 beds. These low mean scores may have arisen from critical problems within the hospital foodservice operations. The most needed facility management items for improvement were: storage shelf should be spaced 6 inches from the floor and walls, the use of three compartment sinks, utility sinks and cleaning facilities, with a floor drain for cleaning mops or liquid wastes, a ventilation hood designed to prevent dripping onto food, cooking facilities should be disassembled for washing and sanitizing, a separated hand washing sink and a sanitized food board for each area should be provided, all toxic material must have warning labels attached, and be stored in an area away from food preparation under padlock. The evaluation tool consisted of 14 dimensions, with 65 check-off items. The results of this study will provide basic facilities' guidelines to regulators, or foodservice industry personnel, wishing to build, or expend, and establish an efficient flow of food. As a result, food borne illnesses will be effectively prevented, and the Nation's health will be promoted for the development of their own sanitation standards, with a checklist for the safe production of foods.

Distribution of Radon Concentration at Subway Station in Seoul (서울시 지하철역사의 라돈농도분포 조사)

  • Lee Cheol-Min;Kim Yoon-Shin;Kim Jong-Cheol;Jeon Hyung-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.469-480
    • /
    • 2004
  • The radon concentrations were measured to survey distribution of radon concentrations in Seoul subway stations. The radon concentrations in air and water were measured at seventeen subway stations(Mapo, Chungjongno, Sodaemun, Kwanghwamun, Chongno3ga, Ulchiro4ga, Tangdaemun, Sangildong on Line 5;Nowon, Chunggye, Hagye, Kongnung, Taenung, Mokkol, Chunghwa, Sangbong, Myomok on Line 7) using the $RAdtrak^{TM}$ radon gas detector, Pylon AB-5 continuous passive radon detector and liquid scintillation counting method from January to May 1999. The major results obtained from this study were as follows: The long-term mean concentrations of radon were $61.8\;Bq/m^3$ in office, $78.9\;Bq/m^3$ in platform, $38.2\;Bq/m^3$ in concourse and $20.1\;Bq/m^3$ in outdoor, respectively. These levels were less than the action level ($148\;Bq/m^3$) of the U.S. EPA. The highest level of short-term mean concentrations was $116.55\;Bq/m^3$ at Chongno3ga station on the 5th line subway stations, while the lowest mean concentration was $19.55\;Bq/m^3$ at Mokkol station on the 7th line subway stations. The highest concentration of radon in the road water and storing underground water in the subway stations was $234.7\;KBq/m^3\;and\;155.5\;KBq/m^3$ in Sodaemun subway station, respectively. The results suggest that radon concentration in subway stations seems to be affected by ventilation and radon concentratin in underground water in the subway stations.

Analysis of Dynamic Characteristics of Pneumatic Driving Solenoid Valve (공압구동용 솔레노이드밸브의 동특성 해석)

  • Jang, Je-Sun;Kim, Byung-Hun;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.731-736
    • /
    • 2011
  • A pneumatic driving solenoid valve operates pneumatic control devices by opening/closing operating flow passage when the command is given by control system for the liquid-propellant feeding system of space launch vehicle. The simulation model of pneumatic driving solenoid valve is designed with AMESim to verify the designs and evaluate the dynamic characteristics and pneumatic behaviors of valve. To validate a valve simulation model, the simulation results of their operating durations of valve by AMESim analysis are compared with the results of experiments. In addition, the results of internal flow simulation with FLUENT are utilized to improve the accuracy of valve-modeling. Using the model, we analyze performance of valve; opening/closing pressure, operating time on various design factors; shape of control valve seat, drainage seat, rate of sealing diameter, volume of control cavity. This study will serve as one of reference guides to enhance the developmental efficiency of ventilation-relief valves with the various operating conditions, which shall be used in Korea Space Launch Vehicle-II.

  • PDF

Analysis of Dynamic Characteristics and Performance of Solenoid Valve for Pressurization Propellant Tank (추진제탱크 가압용 솔레노이드밸브의 작동특성 분석 및 해석)

  • Jang, Je-Sun;Kim, Byung-Hun;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.725-730
    • /
    • 2011
  • A 2-way solenoid valve regulates to maintain the pressure of ullage volume of propellant tanks when the command is given by control system for the liquid-propellant feeding system of space launch vehicle. The simulation model of solenoid valve for pressurization is designed with AMESim to verify the designs and evaluate the dynamic characteristics and pneumatic behaviors of valve. To validate a valve simulation model, the simulation results of their operating durations of valve by AMESim analysis are compared with the results of experiments. Using the model, we analyze performance of valve; opening/closing pressure, operating time on various design factors; shape of control valve seat, basic valve seat, rate of sealing diameter. This study will serve as one of reference guides to enhance the developmental efficiency of ventilation-relief valves with the various operating conditions, which shall be used in Korea Space Launch Vehicle-II.

  • PDF

Characteristics of VOCs and Formaldehyde Emitted from Floorings (바닥재로부터 방출되는 휘발성유기화합물과 폼알데하이드 특성)

  • Park, Hyun-Ju;Jang, Seong-Ki;Seo, Soo-Yun;Lim, Jun-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.1
    • /
    • pp.38-45
    • /
    • 2009
  • Since the seventies and the oil crisis, energy-saving measures have led to a reduction in the ventilation of room. The use of synthetic materials which emit various chemical substances had led to an increase in the concentration of indoor pollutants. "Sick building syndrome (SBS)" and "Sick house syndrome (SHS)" are worldwide problems. Also, the number of complaints about indoor air pollution caused by VOCs (Volatile organic compound) and HCHO (Formaldehyde) has increased. It is important that evaluating and understanding emission of indoor air pollutant from building materials. The object of this study was to evaluate emission test method for flooring such as wood based flooring, carpet tile, rubber tile, PVC sheet and tile, and to determine emission of TVOC and form-aldehyde. The quantity of TVOC and carbonyl compounds emission were sampled and measured by Tenax TA and gas chromatography/mass spectrometry (GC/MSD), 2,4-DNPH cartrige with ozone scrubber and high performance liquid from flooring. The TVOC concentration emitted from carpet tile was ($7.419\;mg/m^2 h$) the highest among 5 groups of test materials. In wood based flooring and PVC tile, the emitted concentration of toluene was high. And the dodecane emission was highest in carpet. The concentration of TVOC decreased by an increase in emission test period. After 7 days, the concentration of TVOC from floorings were about 50% below of the concentration at the first day. TVOC emission from wood based flooring, carpet tile, rubber tile, PVC sheet and tile were decreased in 28 days and remained steady after about 15 days. The concentration of formaldehyde emission from floorings showed extremely low.

An Experimental Study on the Critical Velocity Considering the Slope in Tunnel Fire (경사터널내 화재 발생시 경사도가 임계속도에 미치는 영향에 관한 연구)

  • Kim, Seung-Ryoul;Jang, Yong-Jun;Ryou, Hong-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.7-12
    • /
    • 2008
  • An experimental study has been conducted to investigate the effect of tunnel slope on critical velocity by using the model funnel of the 1/20 reduced-scale applying the Floods scaling law. the square liquid pool burners were used for methanol, acetone and n-heptane fires. tunnel. Tunnel slopes varied as five different degrees $0^{\circ}$, $2^{\circ}$, $4^{\circ}$, $6^{\circ}$ and $8^{\circ}$. The mass loss rate and the temperatures are measured by a load celt and K-type thermocouples for tunnel slope. Present study results in bigger the critical velocity than the research of Atikinson and Wu using the propane burner. Therefore, when estimating the critical velocity in slope tunnel, the variations of the heat release rate is an important factor. The reason is the ventilation velocity directly affects variation of heat release rate when slope tunnel fire occurred.

A Prediction Model for TVOC and HCHO Emission of Paint Materials (페인트에서 방출되는 TVOC 및 HCHO 방출량 예측모델)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.13-20
    • /
    • 2003
  • It is highly recognized that there is need for protection against indoor air pollution, as we realize environmental pollution is growing, For example, in an indoor environment, a person spends more than 80 percent of their time inside the building. Thus, concern about indoor decoration materials is growing, since they cause pollution in the rooms of an apartment, as well as in offices. As the indoor decoration materials become more diverse and lusurious, so the effect of VOCs(Volatile Organic Compounds) and HCHO(Formaldehy) is growing. The indoor decoration materials cause the Sick Building Syndrome, such as headaches, dizziness, or lack of concentraion, and they in turn cause serious deterioration in people's health. In this study, I probed the status of the indoor air pollution and carried on an investigation and analysis about the prevention technique. In doing so, I performed experimental tests and an assessment of the indoor decoration materials of an apartment. I also examined elements of the emitted and the emission. Finally, I examined the character of emissions, by changing environmental conditions, such as the temperature, humidity, and ventilation. With respect to VOCs tests, I applied the method of solid state adsorption using the adsorptive tube, based on the measurement of the American EPA TO-17, ASTM 5116-97, and the measurement of the Japanese Wall Decoration Industrial Association. The tested sample was analyzed by High Performance Liquid Chromatography, after going through the process of dissolvent extraction. As subjects of the test, Paint were selected. The process of this test is as follows; first, I figured out the character of the emission, by measuring the emitted concentration of VOCs and HOHC from the indoor decoration materials of an apartment. Second, I made a small-scale chamber and the test was processed in the chamber in order to suggest an environment-friendly prediction modlel development.

Recent Progress in Methods of Generating Water Mist for Fire Suppression

  • Guangxuan, Liao;Xin, Huang;Beihua, Cong;Jun, Qin;Jianghong, Liu;Xishi, Wang
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.251-265
    • /
    • 2006
  • To prevent the ozonosphere from being destroyed by Halon, it is an urgent task to find out Halon replacement. As one of the replacements water mist have showed broad applications by its advantages: little pollution to environment (not destroying the ozone layer or bring green house effect), extinguishing fire quickly, consuming a small quantity of water and having little damage to the protected objects. The methods of generating water mist strongly influence fire suppression effectiveness, which determine the cone angle, drop size distribution, flux uniformity, and momentum of the generating spray. The traditional water mist nozzle included pressure jet nozzles, impingement nozzles and twin-fluid nozzles. All of them have more or less disadvantages for fire suppression. Therefore, many research institutes and corporations are taking up with innovations in mist generation. This article provided some recent studies in State Key Laboratory of Fire Science (SKLFS) of University of Science and Technology of China. SKLFS have investigated new methods of generating water mist (i.e. effervescent atomization and ultrasonic atomization). and self developed a series of nozzles and developed advanced DPIVS (Digital Particle Image Velocimetry and Sizing) technique. Characteristics of water mist (the distribution of droplet sizes, flux density, spray dynamics and cone angle) produced by these nozzles were measured under different conditions (work pressure, nozzle geometry, etc.) using LDV/APV and DPTVS systems. A series of experiments were performed to study the fire suppression effectiveness in different fire scenario (different kindsof the fuel, fire size and ventilation conditions). The fire extinguishing mechanisms of water mist was also discussed.

  • PDF

Experimental and Numerical Investigation of the Effect of Load and Speed of T-GDI Engine on the Particle Size of Blow-by Gas and Performance of Oil Mist Separator (T-GDI 엔진의 속도 및 하중이 블로우바이 가스의 오일입자 크기와 오일분리기 성능에 미치는 영향에 대한 실험 및 수치적 연구)

  • Jeong, Soo-Jin;Oh, Kwangho
    • Journal of ILASS-Korea
    • /
    • v.25 no.4
    • /
    • pp.162-169
    • /
    • 2020
  • The worldwide focus on reducing the emissions, fuel and lubricant consumption in T-GDI engines is leading engineers to consider the crankcase ventilation and oil mist separation system as an important means of control. In today's passenger cars, the oil mist separation systems mainly use the inertia effect (e.g. labyrinth, cyclone etc.). Therefore, this study has investigated high efficiency cylinder head-integrated oil-mist separator by using a compact multi-impactor type oil mist separator system to ensure adequate oil mist separation performance. For this purpose, engine dynamometer testing with oil particle efficiency measurement equipment and 3D two-phase flow simulation have been performed for various engine operating conditions. Tests with an actual engine on a dynamometer showed oil aerosol particle size distributions varied depending on operating conditions. For instance, high rpm and load increases bot only blow-by gases but the amount of small size oil droplets. Submicron-sized particles (less than 0.5 ㎛) were also observed. It is also found that the impactor type separator is able to separate nearly no droplets of diameter lower than 3 ㎛. CFD results showed that the complex aerodynamics processes that lead to strong impingement and break-up can strip out large droplets and generate more small size droplets.