• 제목/요약/키워드: Liquid subcooling

검색결과 51건 처리시간 0.023초

강제대류 및 핵비등영역에 있어서 액적유량과 분무냉각 열전달의 상관관계에 관한 연구 (Correlation of Droplet Flow Rate and Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region)

  • 김영찬
    • 한국분무공학회지
    • /
    • 제13권3호
    • /
    • pp.143-148
    • /
    • 2008
  • In the present study, the correlation between the Nusselt number and Reynolds number was developed for forced convection and nucleate boiling region in spray cooling. Also the effect of droplet subcooling on spray cooling heat transfer was investigated. Full cone spray nozzles were employed for spray cooling experiment, and water and FC-77 were used for developing the correlation. From the experimental results, the correlation between the Nusselt number and Reynolds number based on droplet-flow-rate was developed. The correlation shows good predictions with ${\pm}30%$ error for water and FC-77.

  • PDF

원통형 용기내의 상변화물질에서의 응고 열전달에 관한 연구 (경사각 변화의 영향) (A Study on Heat Transfer Phenomena during Solidification in a Circular Tube Containing Phase Change Material (Effect of Inclination))

  • 송하진;김영중;오수철;임장순
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.182-192
    • /
    • 1994
  • This paper focuses on the investigation of the heat transfer phenomena that occur inside the cylindrical tube. The inclination of the tube is adopted as a principal parameter varying from vertical to horizontal. The phase change material employed in this experiment is 99 percent pure n-docosane paraffin($C_{22}$ $H_{46}$). It is found that the amount of solidified mass during a prescribed solidifying period is not sensitive to the inclination of the tube but to the local layer thickness. It is studied that the latent energy is the largest contributor to the total extracted energy. The sensible energy($E_{s1}$, $E_{s2}$, $E_{s3}$) may not be negligible at the large wall-subcooling and initial-liquid-superheating, also at the first step of solidifying.

  • PDF

Derivation of Mechanistic Critical Heat Flux Model and Correlation for Water Based on Flow Excursion

  • Chang, Soon-Heung;Kim, Yun-Il;Baek, Won-Pil
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.349-355
    • /
    • 1996
  • In this study, the mechanistic critical heat flux (CHF) model and correlation for water are derived based on flow excursion (or Ledinegg instability) criterion and the simplified two-phase homogeneous model. The relationship between CHF for the water and the principal parameters such as mass flux heat of vaporization, heated length-to-diameter ratio, vapor-liquid density ratio and inlet subcooling is derived on the developed correlation. The developed CHF correlation predicts very well at the applicable ranges, 1 < P < 40 bar, 1, 300 < G 27, 00 kg/$m^2$s and inlet quality is less than -0.1. The overall mean ratio of predicted to experimental CHF value is 0.988 with standard deviation of 0.046.

  • PDF

高溫表面의 冷却時 再水着 溫度 에 관한 硏究 (A Study of Rewetting Temperature in Cooling of Hot Surfaces)

  • 정문기;이영환;박종석
    • 대한기계학회논문집
    • /
    • 제9권4호
    • /
    • pp.463-470
    • /
    • 1985
  • 본 논문에서는 가열관을 이용한 실험과 고온표면위에 놓인 물방울의 증발실험 을 통하여 재수착온도에 미치는 영향인자들을 분석하였으며, 이러한 분석결과를 토대 로 재수착온도상관식을 제시하였다.

수평관에서 R22 대체냉매 및 R134a의 포화증기 온도변화에 따른 외부 응축 열전달계수에 관한 연구 (External Condensation Heat Transfer Coefficients of R22 Alternative Refrigerants and R134a According to the Saturated Vapor Temperature Change on a Smooth Tube)

  • 유길상;황지환;박기정;정동수
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.729-735
    • /
    • 2005
  • In this study, external condensation heat transfer coefficients (HTCs) were measured on a horizontal smooth tube at the saturated vapor temperature of $30^{\circ}C,\;39{\circ}C,\;and\;50^{\circ}C$ for R22, R410A, R407C, and R134a with the wall subcooling of $3\~8^{\circ}C$. The HTCs of all refrigerants are the highest at $30^{\circ}C,\;39{\circ}C,\;and\;50^{\circ}C$ in order. This trend is due to its excellent thermodynamic properties of the liquid phase. The measured data of HTCs were compared with the calculated ones by Nusselt's equation for a smooth tube. Measured HTCs of R22, R134a, R410A are $4.2\~7.5\%$ higher than prediction respectively while those of R407C are $15.6\~28.9\%$ lower than the prediction.

병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구 (Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition)

  • 강인석;최동규;김택영
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.

환상이중원관에서 R-113의 비등열전달에 관한 연구 (A Study on the Boiling Heat Transfer of R-113 in a Concentric Annular Tube)

  • 김명환;김철환;오철;윤석훈;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권5호
    • /
    • pp.12-23
    • /
    • 1994
  • The two-phase flow is observed in power plants, chemical process plants, and refrigeration systems etc., and it is very important to solve the heat transfer mechanism of a boiler, an automic reactor, a condenser and various types of evaporators. Recently, the problem of two phase heat transfer is braught up in many regions with development of energy saving technique. In flow boiling system it is necessary to store data in each condition because the heat transfer characteristics of flow boiling region vary by the change of flow pattern and the magnetude of heat flux to tube length, and be subtly affected by the flow and heating condition. So basic study for knowing flow pattern in heat transfer region and the relation between heat transfer characteristic and flow condition is desired to accumulate data in wide variety of liquid and flow system in the study of heat transfer of two phase flow. In this study R-113 was selected as working fluid whose properties were programmed by least square method, and experiment was conducted in the region of mass flow $1.628{\times}10^6$~$4.884{\times}10^6$/kg/$m^2$hr with inlet subcooling 10~3$0^{\circ}C$, sustaining test section inlet pressure to 1.5kg$_f$/$cm^2$abs.

  • PDF

Critical Heat Flux in Uniformly Heated Vertical Annulus Under a Wide Range of Pressures 0.57 to 15.0 MPa

  • Chun, Se-Young;Chung, Heung-June;Hong, Sung-Deok;Yang, Sun-Kyu;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.128-141
    • /
    • 2000
  • The critical heat flux (CHF)experiments have been carried out in a wide range of pressures for an internally heated vertical annulus. The experimental conditions covered ranges of pressures from 0.57 to 15.01 MPa, mass fluxes of 0 kg/$m^2$s and from 200 to 650 kg/$m^2$s, and inlet subcoolings from 85 to 413 kJ/kg. The characteristics of the present data and the effect of pressure on CHF are discussed. Most of the CHFs were identified to dryout of the liquid film in the annular or annular-mist flow. For the mass flux of 200 kg/$m^2$s, there were the indications that the CHF occurred at the transition from annular to annular-mist How in the pressure range of 3~10 MPa. For the mass fluxes of 550 and 650 kg/$m^2$s, the CHFs had a maximum value at a pressure of 2~3 MPa, and the pressure at the maximum CHF values had a trend moving toward the pressure at the peak value of pool boiling CHF as the mass flux decreased. The CHF data under a zero mass flux condition indicate that both the effects of pressure and inlet subcooling on the CHF were smaller, compared with those on the CHF with net water upward flow.

  • PDF

DEVELOPMENT OF A WALL-TO-FLUID HEAT TRANSFER PACKAGE FOR THE SPACE CODE

  • Choi, Ki-Yong;Yun, Byong-Jo;Park, Hyun-Sik;Kim, Hee-Dong;Kim, Yeon-Sik;Lee, Kwon-Yeong;Kim, Kyung-Doo
    • Nuclear Engineering and Technology
    • /
    • 제41권9호
    • /
    • pp.1143-1156
    • /
    • 2009
  • The SPACE code that is based on a multi-dimensional two-fluid, three-field model is under development for licensing purposes of pressurized water reactors in Korea. Among the participating research and industrial organizations, KAERI is in charge of developing the physical models and correlation packages for the constitutive equations. This paper introduces a developed wall-to-fluid heat transfer package for the SPACE code. The wall-to-fluid heat transfer package consists of twelve heat transfer subregions. For each sub-region, the models in the existing safety analysis codes and the leading models in literature have been peer reviewed in order to determine the best models which can easily be applicable to the SPACE code. Hence a wall-to-fluid heat transfer region selection map has been developed according to the non-condensable gas quality, void fraction, degree of subcooling, and wall temperature. Furthermore, a partitioning methodology which can take into account the split heat flux to the continuous liquid, entrained droplet, and vapor fields is proposed to comply fully with the three-field formulation of the SPACE code. The developed wall-to-fluid heat transfer package has been pre-tested by varying the independent parameters within the application range of the selected correlations. The smoothness between two adjacent heat transfer regimes has also been investigated. More detailed verification work on the developed wall-to-fluid heat transfer package will be carried out when the coupling of a hydraulic solver with the constitutive equations is brought to completion.

수직 벽면에서 과냉 핵비등 시 열유속 분배에 관한 실험적 연구 (Experimental Study on Heat Flux Partitioning in Subcooled Nucleate Boiling on Vertical Wall)

  • 송준규;박준석;정샛별;김형대
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.465-474
    • /
    • 2014
  • 본 연구에서는 비등 열유속 분배 모델의 예측 정확성을 검증하기 위하여 수직평판 자연대류 과냉 비등에서 기화, 급랭, 및 단상대류 열전달 기구에 대한 열유속 분배 특성을 실험적으로 조사하였다. 비등 열유속의 분배를 위해 적외선 열화상 기법과 전반사 가시화 기법을 동기화하여 비등 표면의 열유속 분포와 액상-기상 분포를 동시에 측정하여 분석하는 실험을 수행하였다. 실험은 대기압 조건에서 과냉도 $10^{\circ}C$를 가지는 물을 이용하여 수행하였으며, 벽면과열도 $12^{\circ}C$ 및 평균 열유속 $283kW/m^2$ 조건에 대한 실험 결과를 분석에 활용하였다. 실험을 통해 획득된 열유속 분배 결과는 상관식을 이용한 예측 결과와 큰 차이를 보였으며, 기포이탈직경과 기포이탈 시 주변의 과열액체층이 함께 뜯겨져 나가는 효과를 고려한 기포영향인자가 차이를 만드는 주요 원인들로 파악되었다.