• 제목/요약/키워드: Liquid scintillation counter

검색결과 77건 처리시간 0.024초

Effects of Steroid Hormones on Collagen Biosynthesis in Rat Aorta and Uterus

  • 민병무;김왕국;정동균
    • 대한치과의사협회지
    • /
    • 제19권7호통권146호
    • /
    • pp.609-614
    • /
    • 1981
  • Effects of steroid hormones on the collagen biosynthesis in aorta and uterus were studied with ovariectomized Sprague-Dawley rats. Effects of administration of hormones, such as estrogen, testosterone and prednisolone, to the ovariectomized animals were studied, comparing with the control. Each group was injected with ³H-proline and sacrificed, followed by removals of aorta and uterus. Separations and quantitative analyses of proline and hydroxyproline were performed by means of thin layer chromatography; and radioactivities of the separated amino acids were assayed by liquid scintillation counter. Normally the incorporation of ³H-proline into hydroxyproline was greater in uterus than in aorta, and collagen turnover rate of uterus was observed rapid as well than that of aorta. In the two tissues from ovariectomized rats, the incorporation rate of ³H-proline into hydroxypoline was markedly decreased than that of the former. Changes in the turnover rate of collagen in these tissues were not observed. Decrease in ³H-proline incorporation into collagen in ovariectomized rats was markedly antagonized by estrogen, but not influenced by prednisolone in the tissues tested.

  • PDF

밤바구미(Curculiodentipes) 유충의 cyclic AMP 농도와 CAMP-dependent protein kinase 활성도 변화 (concentration of cyclic AMP and activity of cyclic AMP-dependent Protein Kinase in Chestnut Weevil, Curculio dentipes)

  • 류진수;김유경이경로
    • 한국동물학회지
    • /
    • 제37권2호
    • /
    • pp.222-231
    • /
    • 1994
  • 밤바구미 유충기의 whole body로부터 cyclic AMP(CAMP)를 추출하여 농도 변화를 측정하였고 cyclic AMP-dependent protein kinase(PKA)를 부분 정제하여 활성도 변화를 조사하여 CAMP 농도와 PKA 활성도와의 소장관계를 비교하였다 CAMP 농도와 PKA 활성도는 HPLC와 liquid scintillation counter를 이용하여 측정하였다 CAMP 농도는 밤바구미 유충에서 월동전에 0.57 UMlg로 가장 높았고, 월동중에 0. 14 UMIS로 감소하였다가 월동후에 0.29 UMlg로 증가하였다 또한 PKA 활성도는 월동전에 2.56unit/mg로 가장 높았으며, 월동중에 0.62 unit/mg로 감소하다가 월동후에 07 unit/mg로 다시 증가하여 CAMP 농도 변화와 유사한 경향을 나타내었다. 이는 월동전에 휴면에 대비하여 최대의 취식으로 지방체 축적이 가장 많았고, 월동중에는 지방체의 소비가 증대되.기 때문에 감소하였다가, 월동후 휴면 종결과 유충-번데기 탈피를 준비하기 위해 'CAMP 농도와 PKA 활성도는 다시 증가하였다.

  • PDF

Insulin 투여가 백서치수 및 치은의 Collagen 생합성에 미치는 영향 (EFFECT OF INSULIN ADMINISTRATION ON THE COLLAGEN BIOSYNTHESIS IN INCISOR PULP AND GINGIVA OF RAT)

  • 김관식
    • 대한치과의사협회지
    • /
    • 제19권6호통권145호
    • /
    • pp.529-533
    • /
    • 1981
  • The effect of insulin on the collagen metabolism in dental pulp and gingiva was studied using Sprague-Dawley rat and ³H-proline was injected intraperitoneally and then sacrificed according to predetermined schedule. Lower incisor pulp and gingiva were removed immediatedly and hydrolysed with acid. After digestion, proline and hydroxyproline were separated and analysed quantitatively employing thin-layer chromatography and radioactivity of each amino acid was counted by liquid scintillation counter. The label incorporated into lower incisor pulp and gingiva and radioactivity of ³H-hydroxyproline were increased in insulin administered group. And disappearance rate of ³H-hydroxyproline was decreased. Those results indicated that amino acid, I.e. proline transport and collagen biosynthesis were increased in dental pulp and gingiva by insulin administration.

  • PDF

Self-Diffusion of THO within Tactic Poly(2-hydroxyethyl methacrylate) Membranes

  • Kim, Hye-Kyeong;Jhon, Mu-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • 제4권3호
    • /
    • pp.128-132
    • /
    • 1983
  • The self-diffusion experiment of water was performed across two series of tactic poly(2-hydroxyethyl methacrylate), P(HEMA) membranes prepared by crosslinking with various amount of hexamethylene diisocyanate (HMDIC). The tagging material was tritium hydroxide (THO) and the efflux of THO was counted on a Liquid Scintillation Counter. The transport data of THO show that the permeability decreases as the amount of HMDIC increased from 2.5 to 10 mole % and the self-diffusions coefficient shows a parallel trend with it. The diffusivity data was discussed in terms of the change of water structural orderliness within membranes. Using the relation between viscosities and diffusivities derived from Eyring's absolute rate theory, the corresponding viscosities of water within two series of tactic P(HEMA) membranes were obtained. From this, it is seen that the viscosity of water within tactic P(HEMA) membranes may have the same values with those of supercooling water whose temperature ranges from -28 to -$36^{\circ}C.$.

Organic and inorganic carbon-14 in discharges of JSC Institute of Nuclear Materials

  • E.I. Nazarov;A.A. Ekidin;A.V. Kruzhalov;M.E. Vasyanovich;A.I. Lysikov;P.N. Kalinkin;I.M. Russkikh
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2107-2111
    • /
    • 2023
  • The aim of the study is the activity concentration measurements of organic and inorganic 14C in the discharges of JSC "Institute of Nuclear Materials" (INM). In INM the research water-water reactor "IVV-2M" is operating. Collecting of 14C species was performed using a 14C sampler with a chromium oxide and platinum catalysts at different temperatures: 400, 550 and 700 ℃. The measurements of 14C activity were performed using a liquid scintillation counter. The share of organic 14C in emissions ranged from 0.30 to 0.84 and depends on the temperature of the catalyst, core structure and reactor operating mode.

Comparison of the Quantulus 1220 and 300SL Liquid Scintillation Counters for the Analysis of 222Rn in Groundwater

  • Kim, Hyuncheol;Jung, Yoonhee;Lee, Wanno;Choi, Guen-Sik;Chung, Kun Ho;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.395-401
    • /
    • 2016
  • Background: Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting $^{222}Rn$ in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect $^{222}Rn$ in groundwater. Materials and Methods: The Quantulus 1220 and 300SL were used to detect the presence of $^{222}Rn$. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a $^{222}Rn$ calibration source prepared with a $^{226}Ra$ source. Results and Discussion: The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was $0.08Bq{\cdot}L^{-1}$, while that of the 300SL was $0.20Bq{\cdot}L^{-1}$. The analytical results regarding $^{222}Rn$ in groundwater were less than 10% different between these LSCs. Conclusion: The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting $^{222}Rn$ in groundwater. Both LSCs can be applied to determine the levels of $^{222}Rn$ in groundwater under the management of the Ministry of Environment.

인삼사포닌의 모에 미치는 효과에 관한 연구

  • 김창규;심삼주;이옥섭
    • 대한화장품학회지
    • /
    • 제7권1호
    • /
    • pp.1-18
    • /
    • 1979
  • 인삼(人蔘)사포닌으로 처리(處理)한 모발(毛髮)의 인장강도(引張强度)와 신장도(伸張度)를 collagen 가수분해물(加水分解物)로 처리한 모발(毛髮)과 비교(比較)하였다. 모발(毛髮)에 인삼(人蔘)사포닌 흡수량(吸收量)은 high speed liquid chromatography로 측정(測定)하였으며 liquid scintillation counter로 확인(確認)하였다. 모발(毛髮)에 collagen 가수분해물(加水分解物)의 흡수량(吸收量)은 모발(毛髮)을 collagen 가수분해물(加水分解物) 용액(溶液)속에 침적(沈積)시켰을 때 처음 30분(分) 동안은 많은 량(量)의 흡착(吸着)이 일어났으나 1시간(時間) 경과후(經過後)부터는 더 이상(以上)의 증가(增加)는 보이지 않았다. 이와는 반대(反對)로 인삼(人蔘)사포닌의 경우(境遇)는 침적시간(沈積時間)의 증가(增加)에 비례(比例)하여 흡수량(吸收量)의 증가(增加)를 나타내었다. 실험결과(實驗結果)는 인삼(人蔘)사포닌이 collagen 가수분해물(加水分解物) 보다 모발(毛髮)에 더욱 효과적(效果的)임을 보여 주었고, 그리고 인삼(人蔘)사포닌의 모발(毛髮)에 대(對)한 흡수(吸收)와 인장강도(引張强度)의 증가(增加)는 모발(毛髮)의 strain-stress곡선(曲線)과 인삼(人蔘)사포닌의 계면활성(界面活性)에 의(依)해 설명(說明)하였다.

  • PDF

가열에 의한 지하수 중 222Rn 제거율 고찰 (Study on 222Rn reduction rate in boiling groundwater)

  • 김문수;김현구;박선화;김형섭;주병규;김동수;조성진;양재하;권오상;김태승
    • 분석과학
    • /
    • 제28권5호
    • /
    • pp.353-360
    • /
    • 2015
  • 지하수 중 라돈은 끓임으로서 쉽게 제거할 수 있다. 다양한 라돈 농도를 가진 13 개 지하수 시료를 이용하여 가열 시간과 온도를 변경시키며 라돈의 제거효율을 평가하였다. 지하수 시료는 Bladder 펌프를 이용하여 채수하였고 용존산소, 수소이온농도 등의 현장수질은 Flow cell을 이용하여 측정 하였다. 경과시간 및 수온 별로 분취한 시료의 라돈 농도는 액체섬광계수기(LSC)로 분석하였다. 실험결과, 온도가 높을수록 경과시간에 따른 지하수 중 라돈의 제거율도 높아지며 지하수 중 라돈의 초기농도가 높을수록 경과시간에 따른 지하수 중 라돈의 제거율은 낮아진다. 즉, 지하수 중 라돈의 농도가 높을수록 가열에 의한 라돈 제거 시 더 많은 시간과 에너지를 필요로 한다. 따라서 지하수 중 라돈 제거율은 주로 라돈초기농도, 가열온도, 그리고 가열시간에 의해 결정된다.

연구로 2호기 수조 콘크리트의 $^3H$$^{14}C$ 공간분포 (Spatial Distributions of $^3H$ and $^{14}C$ in the Shielding Concrete of KRR-2)

  • 홍상범;김희령;정근호;강문자;정경환;정운수;박진호
    • 방사성폐기물학회지
    • /
    • 제4권4호
    • /
    • pp.329-334
    • /
    • 2006
  • 연구로 2호기 해체과정에서 발생한 방사화된 수조 콘크리트 내의 깊이에 따른 $^3H$$^{14}C$의 방사능 분포를 고온연소로와 액체섬광계수기를 이용하여 분석하였다. 또한 향후 연구로 2호기 해체과정에서 발생된 콘크리트폐기물의 핵종재고량 평가에 활용하기 위하여 $^3H$$^{14}C$ 측정결과와 감마방출핵종과의 상관관계를 도출하였다. $^3H$$^{14}C$의 검출하한값은 0.048 및 0.028 Bq/g이다. 연구로 2호기 수조 콘크리트 내의 $^3H$$^{14}C$의 깊이별 방사능 분포는 콘크리트 표면으로부터 멀어질수록 지수적으로 감소하는 경향을 보여주었다. 또한,$^3H$$^{14}C$의 비방사능은 콘크리트에 존재하는 $^{60}CO$의 비방사능과 좋은 상관관계를 나타내었다.

  • PDF

LSC 장비를 이용한 교정시 Activity 및 Geometry 차이에 의한 영향 평가 (Effect Evaluation by Activity and Geometry Difference in Calibration on LSC)

  • 한상준;이경진;이승진;김희강;박응섭
    • Journal of Radiation Protection and Research
    • /
    • 제33권1호
    • /
    • pp.21-26
    • /
    • 2008
  • Activity가 20만 dpm인 고상 $^3H$ 표준선원을 사용하여 액체섬광계수기에 대한 교정을 수행할 경우 환경시료와는 Activity 및 Geometry 차이가 존재하고, 계측조건 차이로 인해 많은 불확실성이 존재할 수 있지만 이에 대한 연구결과가 없는 실정이다. 따라서 본 연구에서는 민감도분석을 통해 최적의 계측조건을 도출한 후 그 결과에 근거하여 Geometry 및 Activity 차이에 의한 영향을 정량적으로 평가하였고, 각 항목에 의한 영향이 나타날 경우 추가실험을 통해 원인을 규명하였다. 계측 결과에 대한 검증을 수행하기 위해 Chi-square test와 방사능오차분석을 수행하였고, 민감도분석 결과 본 연구에서 제안한 방법이 기존 방법에 비해 $1{\sim}3%$정도 오차가 감소하였다. 방사능오차분석 결과 Activity 차이에 의한 영향은 무시할 수 있었지만 Geometry 차이에 의한 영향이 크게 나타났고, 이에 대한 원인을 규명한 결과 비수용성인 플라스틱용기는 반사체 역할을 하였고, Activity가 높을수록 플라스틱에 의한 영향은 무시할 수 있었으며, 선원형태 차이에 의한 영향이 지배적인 것으로 나타났다.