• 제목/요약/키워드: Liquid nitrogen

검색결과 1,380건 처리시간 0.027초

액체 $N_2$의 동적 절연파괴 특성 (Dynamic Electrical Breakdown Characteristics of Liquid Nitrogen)

  • 김영석;정종만;곽민환;백승명;장현만;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.359-362
    • /
    • 1998
  • Electrical breakdown characteristics of liquid nitrogen(LNd used as both coolant and insulator for high $T_c$ superconductor system is very important. This paper presents dynamic breakdown characteristics of liquid nitrogen by quench penomena of thermal bubble under high electric field. As the result, the breakdown mechanism of $LN_2$ depends on thermal bubble effect. The breakdown voltage decreases slightly with increasing heating. In the Electrode arrangement, electrical breakdown voltage of horizontal arrangement appears lower than that of vertical arrangement.

  • PDF

초전도케이블 냉각시스템의 냉각특성 시험 (Test of The HTS Power Cable Cooling System)

  • 염한길;고득용;김익생;김춘동;김도형
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.281-283
    • /
    • 2003
  • High temperature superconducting power cable requires forced flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65K and 80K. Subcooler heat exchanger uses saturated liquid nitrogen boiling on the shell side to subcool the circulating liquid nitrogen stream that cools the HTS cable. The paper describes performance tests of the cooling system. The test items are heat exchanging performance of subcooler. pressure drop between supply and return lines, heat transfer coefficient inside former, cable cryostat heat leak and simulation of electrical load of HTS cable.

  • PDF

공구와 칩 사이에서의 Liquid Nitrogen의 마찰 효과 (Friction on the Tool-chip Interface Under Liquid Nitrogen Cooling)

  • Jun Seong Chan
    • 대한안전경영과학회지
    • /
    • 제4권2호
    • /
    • pp.237-249
    • /
    • 2002
  • A cutting fluid can improve machining quality and tool life by maintaining the tool toughness and by providing a lubrication effect to reduce the friction between the chip and tool interface. Although liquid nitrogen as an environmentally safe coolant has been widely recognized in cryogenic machining, its function as a lubricant is plausible due to its chemical inertness, physical volatility and low viscosity. Since a reduced friction is a direct witness of the lubrication effect from a tribological viewpoint, this paper presents an evaluation of the apparent friction coefficient on the tool-chip interface in cryogenic cutting operations to prove and characterize the lubricity of LN2 in cryogenic machining. The mathematical approaches have been formulated to derive the normal and frictional forces on the tool-chip interface for the oblique cutting tests.

극저온 터보펌프 성능시험설비의 개발 (Development of Cryogenic Turbopump Test Facility)

  • 강정식;김진선;김진한
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.340-345
    • /
    • 2003
  • Cryogenic turbopump test facility(CTTF) is designed and developed. Hydraulic and cavitation performance of turbopump in cryogenic environment can be measured. Working fluid is liquid nitrogen and operating temperature is $-197^{\circ}C$. Liquid nitrogen run tank, catch tank and pressurizing tank has been built and remote tank pressure control system are installed. Maximum power of turbopump is 320kW and its maximum speed is 32000rpm. Cryogenic fluids and lubricating systems are effectively separated that long test times are acquired. Therefore hydraulic and cavitation performance can be measured accurately and effectively. This facility will contribute greatly to the development of turbopump for KSLV.

  • PDF

극저온 액체의 동적 절연파괴 특성 (Dynamic Electrical Breakdown Characteristics of Cryogenic Liquid)

  • 김상현;김현희;김영석;정종만;정순용
    • 한국전기전자재료학회논문지
    • /
    • 제11권4호
    • /
    • pp.321-326
    • /
    • 1998
  • Electrical breakdown characteristics of liquid nitrogen($LN_2$) taking into consideration for application of high $T_c$ superconductor is very important. Also $LN_2$ will be used as both coolant and insulator in superconducting generator. In this paper, we investigated ac breakdown characteristics of cryogenic nitrogen gas above a $LN_2$ for rod-to plane electrode configuration. As result the breakdown mechanism of $LN_2$is dependence on bubble effect. And breakdown voltage is a ratio on bubble s size but electrodes arrangement is to make no difference. The breakdown voltage decreases slightly with increasing flow velocity, it again decreases abruptly with increasing flow velocity. These results were interpreted as the within pressure of rod electrode and Maxwell force.

  • PDF

고온초전도 케이블의 유전 특성 (Dielectric Characteristics of HTS Cable)

  • 곽동순;김해종;조전욱;성기철;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.64-68
    • /
    • 2002
  • According to the increasing power demand for the future construction of many underground cables will be required. However, construction of new ducts for power cables will be more difficult. Therefore, research work for realizing the high temperature superconducting(HTS) cable has advanced, where the development of electrical insulating system at cryogenic temperature is one of the major researches. For an electrical insulation design of HTS cable, it is important to understand not only breakdown but also partial discharge and dielectric loss($tan{\delta}$) in liquid nitrogen/paper composite insulation system. In this paper, we investigated breakdown characteristics in liquid nitrogen/paper composite insulation system for the application to HTS cable. And, we studied the breakdown characteristics of the multi-layer and butt gap of the insulation papers in liquid nitrogen. Also, we measured dielectric loss($tan{\delta}$) of the mini-model Cable made of TERLAM IPP.

  • PDF

Insulation Characteristics of the Model Cable for 22.9 kV Class HTS Power Cable

  • Kim, Hae-Jong;Seong, Ki-Chul;Cho, Jeon-Wook;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Kim, Sang-Hyun
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.542-543
    • /
    • 2005
  • In this paper, describes the fabrication and dielectric insulation characteristics experimental results of the model cable for the 22.9kV class HTS power cable. The model cable were tested with partial discharge(PD), AC and impulse withstand voltage in liquid nitrogen($LN_2$) and liquid nitrogen pressure. In these test results, PD inception stress and AC, impulse breakdown strength increase as the pressure of the liquid nitrogen increases.

  • PDF

아미노산 액비가 벤트그라스잔디(Bentgrass)의 생장과 토양에 미치는 영향 (The Effect of Liquid Fertilizer Contained Amio acids on Growth of Bentgrass(Agrostis palustris Huds) and the Chemical Characteristics of Soil)

  • 김영선;이규승;함선규
    • 한국잔디학회:학술대회논문집
    • /
    • 한국잔디학회 2004년도 제17차 한국잔디학회 정기총회 및 춘계학술발표회
    • /
    • pp.24-31
    • /
    • 2004
  • 본 실험은 잔디에 아미노산 비료를 시비하였을 때, 잔디의 생육과 토양에 미치는 영향에 대해 조사하였다. 토양의 화학성을 비교한 결과 아미노산 액비 처리구에서의 토양 중 질소 이용율이 대조구에 비해 증가하였다. 작물의 화학성을 비교한 결과 아미노산 액비 처리구에서 질소 함량, 고토 함량 및 엽록소함량이 대조구에 비해 높았고, 잔디의 생체중과 건물중이 증가하였다 본 실험을 통해 아미노산 액비를 시비할 경우 잔디의 토양 중 질소 이용율이 증가하여 잔디의 생육에 도움이 되고 있음을 알 수 있었다.

  • PDF

Flow boiling of liquid nitrogen in narrow annular channels

  • Zhang P.;L., Qi S.;Z., Wang R.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권4호
    • /
    • pp.1-5
    • /
    • 2008
  • Flow and heat transfer characteristics of liquid nitrogen in narrow annular channels are very important for many practical applications. In the present study, the experimental investigation of flow boiling of liquid nitrogen in narrow annular channels with gap size of 0.2 and 0.5 mm is carried out. The pressure drop and heat transfer coefficients are experimentally measured. The comparison of the theoretical models for the pressure drop and the correlations of the flow boiling to the experimental results are carried out.

Concentric Double Pipe 열교환기에서 냉각수 급랭 현상의 모사에 대한 연구 (Study on Simulation of Cooling Water through Concentric Double Pipe Heat Exchanger )

  • 최안철;이성우;신익호;최성웅
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.741-747
    • /
    • 2023
  • In this study, the heat transfer characteristics were numerically analyzed to investigate the possibility of utilizing cooling water using liquid nitrogen. From the study, as the mass flow rate of the hot fluid increased, the heat transfer rate increased by 8.9-81.7%. And lowering the inlet temperature of the hot fluid resulted in increase in the heat transfer rate by 33.8-71.5%. As for the filling level of liquid nitrogen, as higher filling level led to a decrease in the outlet temperature and an increase in the overall heat transfer coefficient.