• 제목/요약/키워드: Liquid line

검색결과 537건 처리시간 0.035초

Tuned liquid column dampers with adaptive tuning capacity for structural vibration control

  • Shum, K.M.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • 제20권5호
    • /
    • pp.543-558
    • /
    • 2005
  • The natural frequencies of a long span bridge vary during its construction and it is thus difficult to apply traditional tuned liquid column dampers (TLCD) with a fixed configuration to reduce bridge vibration. The restriction of TLCD imposed by frequency tuning requirement also make it difficult to be applied to structure with either very low or high natural frequency. A semi-active tuned liquid column damper (SATLCD), whose natural frequency can be altered by active control of liquid column pressure, is studied in this paper. The principle of SATLCD with adaptive tuning capacity is first introduced. The analytical models are then developed for lateral vibration of a structure with SATLCD and torsional vibration of a structure with SATLCD, respectively, under either harmonic or white noise excitation. The non-linear damping property of SATLCD is linearized by an equivalent linearization technique. Extensive parametric studies are finally carried out in the frequency domain to find the beneficial parameters by which the maximum vibration reduction can be achieved. The key parameters investigated include the distance from the centre line of SATLCD to the rotational axis of a structure, the ratio of horizontal length to the total length of liquid column, head loss coefficient, and frequency offset ratio. The investigations demonstrate that SATLCD can provide a greater flexibility for its application in practice and achieve a high degree of vibration reduction. The sensitivity of SATLCD to the frequency offset between the damper and structure can be improved by adapting its frequency precisely to the measured structural frequency.

한전 초전도전력케이블 냉각시스템 성능시험 (Performance Test of Cooling System for the KEPCO HTS Power Cable)

  • 양형석;김동락;손송호;임지현;최하옥;이병섭;최연석;류희석;황시돌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2206-2210
    • /
    • 2007
  • As a power transmission line supplying power to a densely populated city, the high temperature superconducting (HTS) cable is expected to one of the most effective cables with a compact size because of its high current density. The verification of HTS power cable system have been progressed by KEPRI. A cooling system for a 3-phase 100m HTS power cable with 22.9kV/1.25kA was installed and tested at KEPCO's Gochang power testing center in Korea. The system consists of a liquid nitrogen decompression cooling system with a cooling capacity of 3kW and a closed circulation system of subcooled liquid nitrogen. Several performance tests of the cable system with respect to the cooling such as cooling capacity, heat load and temperature stability, were performed at several temperatures. Thermal cycle test, cool-down to liquid nitrogen temperature and warm-up to room temperature, was also performed to investigate thermal cycle influences. The outline of the installed cooling system and performance test results are presented in this paper.

  • PDF

A new description of the fractal dimension of particle aggregates in liquid medium

  • Xing, Jun;Ding, Shiqiang;Liu, Zhengning;Xu, Jirun
    • 한국입자에어로졸학회지
    • /
    • 제11권4호
    • /
    • pp.99-105
    • /
    • 2015
  • The possible existence forms of particle aggregates in liquid medium are classified into four different types according to their morphological characteristics, including the single particles that are separated from each other, the linear aggregates in which all component particles are located in a line, the planar aggregates where all particles are arranged on a plane, and the volumetric aggregates where all particles forms a three-dimensional space. These particle aggregates with different space morphologies have different fractal dimensions and different influence on the rheological phenomena of the solid-liquid system. The effects of various aggregates on the suspension viscosity are analyzed and related with the particle concentration, and then a mathematical model is presented to determine the fractal dimensions of various aggregates by measuring the apparent viscosity of the solid-liquid system. In the model, the viscous fractal dimension is developed as a new concept, the fractal dimensions of different aggregates can be obtained separately and then the relative components of various aggregates experimentally analyzed.

Modeling of Liquid Entrainment and Vapor Pull-Through in Header-Feeder Pipes of CANDU

  • Cho Yong Jin;Jeun Gyoo Dong
    • Nuclear Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.142-152
    • /
    • 2004
  • The liquid entrainment and vapor pull-through offtake model of RELAP5/MOD3 had been developed for SBLOCA (Small Break Loss of Coolant Accident). The RELAP5/MOD3 model for horizontal volumes accounts for the phase separation phenomena and computes the flux of mass and energy through a branch when stratified conditions occur in the horizontal pipe. In the case of CANDU reactor, this model should be used in the coolant flow of 95 feeders connected to the reactor header component under the horizontal stratification in header. The current RELAP5 model can treat the only 3 directions junctions; vertical upward, downward, and side oriented junctions, and thus improvements for the liquid entrainment and vapor pull-through model were needed for considering the exact angles. The RELAP5 off-take model was modified and generalized by considering the geometric effect of branching angles. Based on the previous experimental results, the critical height correlation was reconstructed by use of the branch line connection angle and validation analyses were also performed using SET. The new model can be applied to vertical upward, downward and angled branch, and the accuracy of the new correlations is more improved than that of RELAP5.

LC/MS/MS를 이용한 수중의 카바릴·유기인계 농약 동시분석 (Simultaneous determination of carbaryl & organophosphorous pesticides in water by liquid chromatography-tandem mass spectrometry)

  • 박근영;신정철;표동진
    • 분석과학
    • /
    • 제31권1호
    • /
    • pp.39-46
    • /
    • 2018
  • 온라인 고체상 추출을 이용한 LC/MS/MS를 사용하여 carbaryl과 유기인계 농약 7 종을 동시에 분석하는 방법을 확립하였다. 분석 대상농약은 carbaryl, diazinon, methyl-demeton, fenitrothion, malathion, parathion, phenthoate, EPN 등 8 종이다. 본 연구에서는 온라인 고체상 추출과 LC/MS/MS의 ESI positive mode로 전처리 없이 물 시료 $500{\mu}L$를 직접 주입하여 10분안에 분석하였다. 농약 8 종의 회수율은 86.8~100 % 였고, 정확도는 90.6~98.8 %로 90 %이상이었고, 정밀도는 1.3~5.2 %로 나타났으며 검출한계 및 정량한계는 각각 $0.05{\sim}0.28{\mu}g/L$, $0.16{\sim}0.89{\mu}g/L$ 였다. $0.5{\mu}g/L$에서 $8.0{\mu}g/L$까지 다섯 개의 농도로 검량선을 작성한 결과 모든 물질의 상관계수(r2)가 0.99이상을 나타냈다. 방법의 유효성 평가를 한 결과 모든 내용에서 적합하므로확립한 분석방법으로 수질 시료에서 농약을 조사한 결과 모두 검출되지 않았다.

LCD(Liquid Crystal Display) Panel의 결점 검사 (Automatic Inspection for LCD Panel Defect)

  • 이유진;이중현;고국원;조수용;이정훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.946-949
    • /
    • 2005
  • This paper deals with the algorithm development that inspects defects such as Bright Defect Dots, Dark Defect Dots, and Line Defect caused by the process of LCD(Liquid Crystal Display). While most of LCD production process is automated, the inspection of LCD panel and its appearance depends on manual process. So, the quality of the inspection is affected by the condition of worker. Especially, the more LCD size increases, the more the worker feels fatigued, which causes the probability of miss judgement. So, the automated inspection is required to manage the consistent quality of the product and reduce the production costs. In this paper, to solve these problems, we developed the imaging processing algorithm to inspect the defects in captured image of LCD. Experimental results reveal that we can recognize various types of defect of LCD with good accuracy and high speed.

  • PDF

Acrylonitrile 제조공정에서 Acstonitrile의 회수에 관한 연구 (A Study on the Recovery of Acetonitrile in the Process of Acrylonitrile)

  • 이진우;박동원
    • 공업화학
    • /
    • 제5권6호
    • /
    • pp.1016-1023
    • /
    • 1994
  • Acrylonitrile 제조시 부산물로 생성되는 acetonitrile-water 공비혼합물에서 용매추출하여 acetonitrile을 회수하기 위하여 benzene, toluene, o-xylene, ethylacetate 및 monochlorobenzene을 용매로 선택하여 $25^{\circ}C$ 에서 solvent(1)-water(2)-acetonitrile(3)계의 액-액 평형데이타를 구하였으며, 그 실험데이타의 건전성을 조사하였고, tie line과 plait point조성을 결정하였다. 또한 NRTL, UNIQUAC 및 modified UNIQUAC모델식에 적용하여 parameter를 추산하고 각 용매에 대한 분배계수와 선택도를 결정하였다.

  • PDF

신경망무고장모델과 이중퍼지로직을 사용한 냉방기 고장진단 알고리즘 (Fault Diagnosis Algorithm of an Air-conditioning System by using a Neural No-fault Model and a Dual Fuzzy Logic)

  • 한도영;정남철
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.791-799
    • /
    • 2006
  • The fault diagnosis technologies may be applied in order to decrease the energy consumption and the maintenance cost of an air-conditioning system. In this paper, a fault diagnosis algorithm was developed by using a neural no-fault model and a dual fuzzy logic. Five different faults, such as the compressor valve leakage, the liquid line blockage, the condenser fouling, the evaporator fouling, and the refrigerant leakage of an air-conditioning system, were considered. The fault diagnosis algorithm was tested by using a fault simulation facility. Test results showed that the algorithm developed for this study was effective to detect and diagnose various faults. Therefore, this algorithm may be practically used for the fault diagnosis of an air-conditioning system.