• Title/Summary/Keyword: Liquid ambient

Search Result 283, Processing Time 0.026 seconds

Effects of Temperature on the Pharmacokinetics of Ciprofloxacin in the Cultured Black Rockfish (Sebastes schlegeli) and Olive Flounders (Paralichthys olivaceus)

  • Kim Jin Woo;Jo Mira;Jung Sung Hee;Jee Bo Young;Choi Dong Lim;Jo QTae
    • Fisheries and Aquatic Sciences
    • /
    • v.5 no.3
    • /
    • pp.200-205
    • /
    • 2002
  • Temperature-dependent pharmacokinetics of ciprofloxacin (CIP) was studied in the cultured olive flounders, Paralichthys olivaceus, and black rockfish, Sebastes schlegeli using high performance liquid chromatography (HPLC) originally developed for quinolone determination from livestock. Pharmacokinetics of CIP was apparently affected by ambient water temperature. In a two-compartment model for flounders after oral dosage of 20 mg/kg, $K_{01},\;at\;13^{\circ}C$ and $23^{\circ}C$ were 4.18 and 1.20/hr, respectively. The $K_{10},\;T_{max}\;and\;C_{max}\;at\;13^{\circ}C$ were 5.574/hr, l4.37${\mu}g/mL\;and\;3.15{\mu}g/mL,$ respectively. The corresponding values at $23^{\circ}C$ were l2.84/hr, 15.39${\mu}g/mL\;and\;6.38{\mu}g/mL$, respectively. The AUC, $T_{1/2} (\alpha)\;and\;T_{1/2}\;(\beta)$ were 278.23 ${\mu}g \cdot hr/mL$, 0.24hr and 47.02hr at $13^{\circ}C$ and 3l7.8l${\mu}g \cdot hr/mL$, 0.30 hrs and 60.78hrs at $23^{\circ}C$ for the flounder, respectively. Similar CIP pharmacokinetics were revealed in the black rockfish after oral dosage of 20 mg/kg under the two water temperature regimes. These pharmacokinetical results have some implication in the optimal usage of recently introduced antibacterials in the farmed fish, which were primarily adapted for poultry and mammalian species.

Stabilization of Retinol through Incorporation into Liposomes

  • 이승철;육현균;이동훈;이경은;황용일;Richard D. Ludescher
    • BMB Reports
    • /
    • v.35 no.4
    • /
    • pp.358-363
    • /
    • 2002
  • Chemical and photochemical processes during storage and preparation rapidly degrade retinol, the most active form of vitamin A. therefore, the efficacy of incorporation into liposomes in order to modulate the kinetics of retinol degradation was investigated. Retinol was readily incorporated into multilamellar liposomes that were prepared form soybean phosphatidylcholine; the extent of the incorporation was 98.14±0.93% at pH 9.0 at a ratio of 0.01 : 1 (wt:wt) retinol : phospholipid. It was only marginally lower at higher retinol concentrations. The pH of the hydration buffer had a small effect. The incorporation efficiency ranged from 99.25±0.47% at pH 3 to 97.45±1.13% at pH 11. The time course of the retinol degradation in the aqueous solution in liposomes was compared to that of free retinol and free retinol with α-tocopherol under a variety of conditions of pH(3, 7, and 11), temperature(4, 25, 37, and 50℃), and light exposure(dark, visible, and UV). The retinol that was incorporated into the liposomes degraded significantly slower than the free retinol or retinol with α-tocopherol at pH 7 and 11. At pH 3, where the free retinol degrades rapidly, the degradation kinetics were similar in liposomes and the presence of α-tocopherol. At pH 7.0 and 4℃ in the light, for example, free aqueous retinol was completely degraded within 2 days, while only 20% of the retinol in the liposomes were degraded after 8 days. In general, the protective effect of the liposome incorporation was greater at low temperatures, at neutral and high pH, and in the dark. The results suggest that protection is greater in the solid, gel phase than in the fluid liquid crystalline phase lipids. These results indicate that the incorporation into liposomes can extend the shelf-life of retinol under a variety of conditions of temperature, pH, and ambient light conditions.

Determination of Antibiotic Residues: I. Extraction and Clean-up Methods for Solid Samples_A Review (시료 중 잔류 항생제 분석 방법: I. 고상 시료 전처리 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.600-627
    • /
    • 2016
  • Korea is one of the countries with a large veterinary antibiotics market, although antimicrobial resistance in bacteria is becoming a serious issue in many countries. The Korean government started to take interest in estimating the effects of livestock manure on rivers and agricultural soils and in monitoring of heavy metals, organic pollutants and antibiotics in the ambient water and soil. In this paper, pre-treatment methods to separate the selected antibiotics from solid samples were reviewed. It is essential to select an efficient and appropriate procedure for pre-treatment due to the high proportion of proteins and organics in biosolid samples. Pre-treatment consists of extraction followed by clean-up. Initially, homogenized samples were extracted by sonication, mechanical agitation or pressurized liquid extraction with methanol/acetonitrile/water mixture under acidic/basic conditions depending on the compound. However, aminoglycosides and colistin were extracted with 5% trichloroacetic acid and HCl, respectively. Since the ${\beta}-lactams$ are easily decomposed in acidic and basic conditions, they were extracted in neutral pH. Filtration with a membrane (pore size, $0.2{\mu}m$) or solid phase extraction with HLB and methanol, as eluents, was normally applied for the clean-up. At least, three different pre-treatment procedures should be adopted to screen all the selected antibiotics in solid samples.

An External Dose Assessment of Worker during RadWaste Treatment Facility Decommissioning

  • Chae, San;Park, Seungkook;Park, Jinho;Min, Sujung;Kim, Jongjin;Lee, Jinwoo
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.81-87
    • /
    • 2020
  • Background: Kori unit #1 is permanently shut down after a 40-year lifetime. The Nuclear Safety and Security Commission recommends establishing initial decommissioning plans for all nuclear and radwaste treatment facilities. Therefore, the Korea Atomic Energy Research Institute (KAERI) must establish an initial and final decommissioning plan for radwaste-treatment facilities. Radiation safety assessment, which constitutes one chapter of the decommissioning plan, is important for establishing a decommissioning schedule, a strategy, and cost. It is also a critical issue for the government and public to understand. Materials and Methods: This study provides a method for assessing external radiation dose to workers during decommissioning. An external dose is calculated following each exposure scenario, decommissioning strategy, and working schedule. In this study, exposure dose is evaluated using the deterministic method. Physical characterization of the facility is obtained by both direct measurement and analysis of the drawings, and radiological characterization is analyzed using the annual report of KAERI, which measures the ambient dose every month. Results and Discussion: External doses are calculated at each stage of a decommissioning strategy and found to increase with each successive stage. The maximum external dose was evaluated to be 397.06 man-mSv when working in liquid-waste storage. To satisfy the regulations, working period and manpower must be managed. In this study, average and cumulative exposure doses were calculated for three cases, and the average exposure dose was found to be about 17 mSv/yr in all the cases. Conclusion: For the three cases presented, the average exposure dose is well below the annual maximum effective dose restriction imposed by the international and domestic regulations. Working period and manpower greatly affect the cost and entire decommissioning plan; hence, the chosen option must take account of these factors with due consideration of worker safety.

Application of Semi-continuous Ambient Aerosol Collection System for Elemental Analysis (대기입자의 원소성분 배출특성연구를 위한 반-연속식 입자채취시스템 적용)

  • Park, Seung-Shik;Ko, Jae-Min;Lee, Dong-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.39-51
    • /
    • 2012
  • Aerosol slurry samples were collected in 60-min interval using Korean Semi-continuous Elements in Aerosol Sampler (KSEAS) between May 19 and June 6, 2010 at an urban site of Gwangju. The $PM_{2.5}$ samples were collected with a flow rate of 16.7 L/min and particles are grown by condensation of water vapor in a condenser maintained at ${\sim}5^{\circ}C$ after saturation by direct injection of steam. The resulting droplets are collected in a liquid slurry with a airdroplet separator. Concentrations of 16 elements (Al, Fe, Mn, Ca, K, Cu, Zn, Pb, Cd, Cr, Ti, V, Ni, Co, As, Se) in the collected slurry samples were determined off-line by ICP-MS. KSEAS sample analysis encompassed the sampling periods for which 24-hr average elemental species concentrations were calculated for comparison with those derived from 24-hr integrated filter samples. Relationship between elemental species measured by two methods indicated high correlation coefficients (r), mostly greater than r of 0.80. However, we note that concentrations of Al, K, Ca, Mn, and Fe, which are often associated with crustal elemental particles, in the KSEAS samples, were substantially lower (1.4~11 times) than those found in the typical filter-based samples. This discrepancy is probably due to difficulties in transferring insoluble dust particles to the collection vials in the KSEAS. Temporal profiles of elemental concentrations indicate that some transient events in their concentrations are observed over the sampling periods. For the elemental species studied, atmospheric concentrations during the transient events increased by factors of 4 in Mn~80 in Zn, compared to their background levels. Principle component analyses were applied to the hourly KSEAS data sets to identify sources affecting the concentrations of the metal constituents observed. In this study, we conclude that hourly measurements for particle-bound elemental constituents were extremely useful for revealing the short-term variability in their concentrations and developing insights into their sources.

Determination of Analytical Approach for Ambient PM2.5 Free Amino Acids using LC-MSMS (LC-MSMS를 이용한 대기 중 PM2.5 유리아미노산 분석 방법 연구)

  • Bae, Min-Suk;Park, Da-Jeong;Lee, Kwon-Ho;Cho, Seung-Sik;Lee, Kwang-Yul;Park, Kihong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.1
    • /
    • pp.54-63
    • /
    • 2017
  • Atmospheric nitrogen containing organic compounds(e.g. amino acids) has attracted considerable attention from the viewpoint of the oceanic biogeochemical cycle of nitrogen as well as the long range transfer. However, only a few measurements of organic nitrogen compounds have been conducted due to analytical difficulties. In this study, total of nine amino acids such as Glutamic acid, Histidine, Arginine, Tyrosine, Cystine, Valine, Methionine, Phenylalanine, Lysine have been analytically determined by Liquid Chromatography - Mass Spectrometry Mass Spectrometry (LC-MSMS). As results, Fragmentor Voltage (FV), Precursor Ion, Collision Energy, Product Ion related to individual amino acid compounds are shown. Based on the operational conditions, Lysine, Glutamine Acid, Tyrosine were analyzed during the China Oriented Smog Period. High concentrations of Lysine, Glutamine Acid, and Tyrosine are discussed with organic carbon (OC), elemental carbon (EC), and water soluble ions. The results can provide to understand the sources with aging process related to amino acids influenced by the long-range transport from the Yellow Sea area.

Development of a new vitrification solution, VSL, and its application to the cryopreservation of gentian axillary buds

  • Suzuki, Mitsuteru;Tandon, Pramod;Ishikawa, Masaya;Toyomasu, Takayuki
    • Plant Biotechnology Reports
    • /
    • v.2 no.2
    • /
    • pp.123-131
    • /
    • 2008
  • Vitrification methods are convenient for cryopreserving plant specimens, as the specimens are plunged directly into liquid nitrogen (LN) from ambient temperatures. However, tissues and species with poor survival are still not uncommon. The development of vitrification solutions with high survival that cover a range of materials is important. We attempted to develop new vitrification solutions using bromegrass cells and found that VSL, comprising 20% (w/v) glycerol, 30% (w/v) ethylene glycol, 5% (w/v) sucrose, 10% (w/v) DMSO and 10 mM $CaCl_2$, gave the highest survival following cryopreservation, as determined by fluorescein diacetate staining. However, the cryopreserved cells showed little regrowth, for unknown reasons. To check its applicability, VSL was used to cryopreserve gentian axillary buds and the performance was compared with those of conventional vitrification solutions. Excised gentian stem segments with axillary buds (shoot apices) were two-step precultured with sucrose to induce osmotic tolerance prior to cryopreservation. Gentian axillary buds cryopreserved using VSL following the appropriate preculturing approach exhibited 78% survival (determined by the regrowth capacity), which was comparable to PVS2 and PVS1 and far better than PVS3. VSL had a wider optimal incubation time (20-45 min) than PVS2 and was more suitable for cryopreserving gentian buds. The optimal duration of the first step of the preculture was 7-11 days, and preculturing with sucrose and glucose gave a much higher survival than fructose and maltose. VSL was able to vitrify during cooling to LN temperatures, as glass transition and devitrification points were detected in the warming profiles from differential scanning calorimetry. VSL and its derivative, VSL+, seem to have the potential to be good alternatives to PVS2 for the cryopreservation of some materials, as exemplified by gentian buds.

Preparation of SiO2/TiO2 Composite Fine Powder by Sol-Gel Process (Sol-Gel Process를 이용한 SiO2/TiO2 복합 미립자의 합성)

  • Koo, S.M.;Lee, D.H.;Ryu, C.S.;Lee, Y.E.
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.301-307
    • /
    • 1997
  • Monodisperse, spherical $SiO_2/TiO_2$ composite fine powders were prepared by modified Sol-Gel process which $TiO_2$ fine Powders was used as a seed particles for condensation of TEOS (Tetraethyl Orthosilicate). The reaction was carried out under $N_2$ atmosphere at ambient temperature using $NH_3$ as a catalyst. Ethanol was used as a solvent. Drying process was carried out with vacuum trap which cooled by liquid $N_2$. The reaction variables were the concentration of TEOS, the concentration of ammonia, the size of $TiO_2$ seed and molar ratio of $SiO_2/TiO_2$. The optimum condition for the preparation of $SiO_2/TiO_2$ composite fine powders without agglomeration was [TEOS]=0.3M, [$NH_3$]=0.7M, size of $SiO_2/TiO_2$ seed = 200~300nm.

  • PDF

Tensile Adhesive Chracteristics of Waterproofing System for Concrete Bridge Decks (교량 바닥판 조건에 따른 교면방수 시스템의 인장접착 특성)

  • Lee, Byung-Duck;Shim, Jae-Won;Park, Sung-Ki;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.4 no.3 s.13
    • /
    • pp.15-23
    • /
    • 2002
  • The waterproofing system's performance is known to show a determing by complex interaction of material factors, design details, and the quality of construction, and the waterproofing integrity of waterproofing membranes is determined by the bond to the deck and the amount of damage to the waterproofing membrane. In this research, the basic properties of waterproofing membranes on market and the tensile adhesive chracteristics of waterproofing systems of concrete bridge deck have also been investigated in the view of the damages frequently reported from job site. For the tensile adhesive strength of sheet waterproofing membranes, the results after asphalt concrete paving tends to increase more than before those. The results of the liquid waterproofing membranes are upside-down, and the more concrete has strength, the more strength of tensile adhesive increase. The ambient temperature of asphalt concrete when application of the waterproofing membrane has considerable influence on the performance of waterproofing system. As described above, waterproofing system can be influenced by several factors. If they are not considered under construction, the overlooking will cause the damages of pavement and waterproofing system after traffic opening.

  • PDF

Investigation of a Pseudo Capacitor with Polyacrylonitrile based Gel Polymer Electrolyte

  • Harankahawa, Neminda;Weerasinghe, Sandaranghe;Vidanapathirana, Kamal;Perera, Kumudu
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.107-114
    • /
    • 2017
  • Pseudo capacitors belong to one group of super capacitors which are consisted with non carbon based electrodes. As such, conducting polymers and metal oxide materials have been employed for pseudo capacitors. Conducting polymer based pseudo capacitors have received a great attention due to their interesting features such as flexibility, low cost and ease of synthesis. Much work has been done using liquid electrolytes for those pseudo capacitors but has undergone various drawbacks. It has now been realized the use of solid polymer electrolytes as an alternative. Among them gel polymer electrolytes (GPEs) are in a key place due to their high ambient temperature conductivities as well as suitable mechanical properties. In this study, composition of a polyacrylonitrile (PAN) based GPE was optimized and it was employed as the electrolyte in a pseudo capacitor having polypyrrole (PPy) electrodes. GPE was prepared using ethylene carbonate (EC), propylene carbonate (PC), sodium thiocyanate (NaSCN) and PAN as starting materials. The maximum room temperature conductivity of the GPE was $1.92{\times}10^{-3}Scm^{-1}$ for the composition 202.5 PAN : 500 EC : 500 PC : 35 NaSCN (by weight). Performance of the pseudo capacitor was investigated using Cyclic Voltammetry technique, Electrochemical Impedance Spectroscopy (EIS) technique and Continuous Charge Discharge (GCD) test. The single electrode specific capacity (Cs) was found out to be 174.31 F/g using Cyclic Voltammetry technique at the scan rate of 10 mV/s and within the potential window -1.2 V to 1.2 V. The same value obtained using EIS was about 84 F/g. The discharge capacity ($C_d$) was 69.8 F/g. The capacity fade over 1000 cycles was rather a low value of 4%. The results proved the suitability of the pseudo capacitor for improving the performance further.