• Title/Summary/Keyword: Liquid Target

Search Result 324, Processing Time 0.023 seconds

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

The Clinical Significance and Detection of Intraperitoneal Micrometastases by $ThinPrep^{(R)}$ Cytology with Peritoneal Lavage Fluid in Patients with Advanced Gastric Cancer (진행성 위암 환자에서 복강 내 미세전이 진단을 위한 복강 세척액 $ThinPrep^{(R)}$ 세포진 굄사의 임상적 의의)

  • Ryu, Chun-Kun;Park, Jong-Ik;Min, Jae-Seok;Jin, Sung-Ho;Park, Sun-Hoo;Bang, Ho-Yoon;Chae, Gi-Bong;Lee, Jong-Inn
    • Journal of Gastric Cancer
    • /
    • v.8 no.4
    • /
    • pp.189-197
    • /
    • 2008
  • Purpose: Peritoneal lavage cytology is regarded as a useful diagnostic test for detecting intraperitoneal micrometastsis. However, there are currently no reports about cytological examination with $ThinPrep^{(R)}$ (CY), a newly introduced fluid-based diagnostic system, in patients with advanced gastric cancer (AGC). This study was performed to analyze the clinical significance of intraoperative peritoneal lavage for CY in AGC patients. Materials and Methods: 424 AGC patients were suspected to have serosal exposure macroscopically during surgery and they underwent intraoperative peritoneal lavage for CY between 2001 and 2006 at Korea Cancer Center Hospital. The clinical data, pathological data and CY results were collected and analyzed retrospectively. Results: The percentage of cytology positive results was 31.1%, and this was well correlated with the T-stage, N-stage and P-stage. The 3-year survival rates of CY0 and CY1 were 68.1% and 25.9%, respectively. According to the P-stage and CY, the 3-year survival rates were 71.1% in P0CY0, 38.9% in P0CY1, 38.5% in P1/2/3CY0 and 11.0% in P1/2/3CY1. Interestingly, both the P0CY1 and P1/2/3CY0 survival curves were similar figures, but they were significantly different from those of the other groups. Multivariate analysis indicated that CY was an independent, strong prognostic factor for survival, as well as sex, the T-stage, N-stage, P-stage, other metastasis and the serum CEA. CY1 was revealed as a risk factor for peritoneal recurrence in the curative resection group. Conclusion: The results certify indirectly that cytological examination using $ThinPrep^{(R)}$ is a very reliable diagnostic method for detecting intraperitoneal micrometastasis from the fact that it is not only a strong prognostic factor, but it is also a risk factor for peritoneal recurrence in AGC patients. Therefore intraoperative peritoneal lavage should be included in the routine intraoperative staging workup for AGC, and its result will provide a good target for the treatment of peritoneal micrometastasis.

  • PDF

A Study on the Analysis of Five Artificial Sweetners in Beverages by HPLC/MS/MS (HPLC/MS/MS를 이용한 음료류 중 인공감미료 동시분석에 관한 연구)

  • Lee, Seong-Bong;Yong, Kum-Chan;Hwang, Sun-Il;Kim, Young-Su;Jung, You-Jung;Seo, Mi-Young;Lee, Chang-Hee;Sung, Jin-Hee;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.327-333
    • /
    • 2014
  • A method for analysis of five artificial sweetners (sodium saccharin, aspartame, acesulfame-K, sucralose, cyclamate) in beverage samples was developed using high-performance liquid chromatography/triple quadrupole mass spectrometry (HPLC/MS/MS). The method uses a single-step dilution for sample preperation. Seperation was achieved on a $C_{18}$ column ($2.1{\times}150mm$, $3.5{\mu}m$) with A- 2% methanol (1 mM ammonium acetate), B-95% methanol (1 mM ammonium acetate) as mobile phase with gradient mode. The quantitation of target compounds was performed by external calibration in selected reaction monitorning (SRM) mode. The coefficient of determination of calibration curve for sodium saccharin, aspartame, acesulfame-K, sucralose and cyclamate were 0.9957, 0.9991, 0.9943, 0.9982 and 0.9948, respectively. The limits of detection (LODs) and limits of quantitation (LOQs) were in the range of 0.001~0.022 mg/L and 0.004~0.073 mg/L, repectively. Recoveries for beverage samples were in the range of 92.76~113.50% with RSD < 10.91%. The method has applied to the determination of the five sweetners in 102 beverage samples. Three artificial sweetners-aspartame, acesulfame-K, sucralose were detected from 42 samples. Sodium saccharin and cyclamate were not detected in all samples.

Evaluation of the Potential of Nitrogen Plasma to Cosmetics (질소 플라즈마의 화장품 가능성 평가)

  • Lee, So Min;Jung, So Young;Brito, Sofia;Heo, Hyojin;Cha, Byungsun;Lei, Lei;Lee, Sang Hun;Lee, Mi-Gi;Bin, Bum-Ho;Kwak, Byeong-Mun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.3
    • /
    • pp.189-196
    • /
    • 2022
  • Plasma refers to an ionized gas that is often referred to as "the fourth phase of matter", following solid, liquid, and gas. Plasma has traditionally been utilized for industrial applications such as welding and neon signs, but its promise in biomedical fields such as cancer treatment and dermatology has lately been recognized. Indeed, due to its beneficial effects in promoting collagen production, improving skin tone, and eliminating harmful bacteria in the skin, plasma treatment constitutes an important target for dermatological research. In this study, a plasma device for cosmetic manufacturing based on nitrogen, the main component of the atmosphere, was designed and assembled. Moreover, nitric oxide (NO) was selected since is easier to follow and evaluate than other nitrogen plasma active species, and its contents were measured to perform a quantitative and qualitative evaluation of plasma. First, an injection method, using different proximities labeled "sinking" and "non sinking" treatments, was performed to test the most efficient plasma treatment method. As a result, it was observed that the formulation obtained by a non sinking treatment was more effective. Furthermore, toner and ampoule were selected as cosmetics formulations, and the characteristics of the formulation and changes in the injected plasma state were observed. In both formulations, the successful injection of NO plasma was 2 times higher in toner formulation than ampoule formulation, and it gradually decreased with time, having dissipated after a week. It was confirmed that the nitrogen plasma used did not affect the stability of the toner and ampoule formulations at low temperature (4 ℃), room temperature (25 ℃), and high temperature (37 ℃ and 50 ℃) conditions. The results of this study demonstrate the potential of plasma cosmetics and highlight the importance of securing the stability of the injected plasma.