• 제목/요약/키워드: Liquid Scintillator

검색결과 22건 처리시간 0.017초

Measurement of Gamma-ray Yield from Thick Carbon Target Irradiated by 5 and 9 MeV Deuterons

  • Araki, Shouhei;Kondo, Kazuhiro;Kin, Tadahiro;Watanabe, Yukinobu;Shigyo, Nobuhiro;Sagara, Kenshi
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.16-20
    • /
    • 2017
  • Background: The design of deuteron accelerator neutron source facilities requires reliable yield estimation of gamma-rays as well as neutrons from deuteron-induced reactions. We have so foar measured systematically double-differential thick target neutron yields (DDTTNYs) for carbon, aluminum, titanium, copper, niobium, and SUS304 targets. In the neutron data analysis, the events of gamma-rays taken simultaneously were treated as backgrounds. In the present work, we have re-analyzed the experimental data for a thick carbon target with particular attention to gamma-ray events. Materials and Methods: Double-differential thick target gamma-ray yields from carbon irradiated by 5 and 9 MeV deuterons were measured using an NE213 liquid organic scintillator at the Kyushu University Tandem accelerator Laboratory. The gamma-ray energy spectra were obtained by an unfolding method using FORIST code. The response functions of the NE213 detector were calculated by EGS5 incorporated in PHITS code. Results and Discussion: The measured gamma-ray spectra show some pronounced peaks corresponding to gamma-ray transitions between discrete levels in residual nuclei, and the measured angular distributions are almost isotropic for both the incident energies. Conclusion: PHITS calculations using INCL, GEM, and EBITEM models reproduce the spectral shapes and the angular distributions generally well, although they underestimate the absolute gamma-ray yields by about 20%.

$Co_2$ 흡수법에 의한 환경시료중 $^{14}C$ 정량 (Determination of $^{14}C$ in Environmental Samples Using $CO_2$ Absorption Method)

  • 이상국;김창규;김철수;김용재;노병환
    • Journal of Radiation Protection and Research
    • /
    • 제22권1호
    • /
    • pp.35-46
    • /
    • 1997
  • $CO_2$ 흡수제와 액체섬광계수기를 이용하여 간단하고 정밀한 $^{14}C$ 정량법을 개발하였다. 또한, 대기 및 생물시료중 $^3H$$^{14}C$ 동시포집을 위한 대기시료 포집장치 및 연소장치를 개발하였다. 본 연구에서 개발한 대기중 $CO_2$ 포집장치의 포집율은 73-89%였으며 연소장치의 연소율은 97%를 나타내었다. 측정시료 조제시 흡수제와 섬광체와의 최적 혼합비는 1:1 였으며 측정시료중 $^{14}C$의 비방사능 농도는 시료조제 후 70일까지 변화하지 않고 매우 안정한 상태를 유지하였고 검출하한치는 0.025 Bq/gC로써 자연준위의 $^{14}C$ 분석에도 활용 가능하였다. 또한, 본 분석법에 의한 $^{14}C$ 분석결과는 벤젠합성범에 의한 결과와 ${\pm}6%$ 오차범위 내에서 상호간 잘 일치하였다. 본 연구에서 검토한 방법을 이용하여 1996년 10월 대전지역 대기중 $^{14}C$의 비방사능을 측정한 결과 0.26-0.27 Bq/gC의 범위로써 전형적인 자연준위를 나타내었다. 한편, 월성 원자력발전소로부터 lkm 떨어진 지점에서의 대기중 $^{14}C$C 비방사능은 $0.54{\pm}0.03$ Bq/gC였으며, 솔잎 및 채소류중 $^{14}C$의 비방사능은 각각 0.56-0.67 Bq/gC 및 0.23-1.41 Bq/gC의 농도범위를 나타내었다.

  • PDF