Liquid Scintillation Counting 에서의 Dimethylaniline 에 依한 消光機構 (Mechanism of Quenching by Dimethylanilines in Liquid Scintillation Counting)

  • 이익춘
    • 대한화학회지
    • /
    • 제8권2호
    • /
    • pp.43-46
    • /
    • 1964
  • Quenching constants, q, determined for N,N-dimethylanilines by liquid scintillation counting indicate that the quenching involves an energy transfer process to these compounds causing strong n-${\pi}$ interaction within the quencher molecule, which is then followed by an non-radiative degradation of the excitation energy to ground state.

  • PDF

A Rapid Method for the Measurement of the Absolute Activity of Carbon-14 in Pea Plant Tissue

  • Kendall, F.H.;Park, Chang-Kyu;Mer, C.L.
    • Applied Biological Chemistry
    • /
    • 제18권2호
    • /
    • pp.56-60
    • /
    • 1975
  • 완두유묘의 자엽 및 뿌리조직중 탄소-14 방사능을 Liquid scintillation counter로 신속히 측정하는 새로운 방법에 관하여 실험하였다. 식물조직을 액체공기에 처리하여 분쇄한 다음 Gel phosphor에 헌탁시켜, Liquid scintillation counter로 측정하였다. 이시료에 다시 내부표준물질을 가한 다음 계측효율을 구하여 Apparent absolute activity를 얻었다. 이렇게 얻은 헌탁시료의 절대방사능은 자기 흡수현상 때문에, 따로 Flask combustion 방법으로 구한 절대방사능 보다는 낮았으나, 항상 비례하였다. 따라서 동일한 실험조건하에서 상술한 비율을 얻으면, 완두조직중 탄소-14의 점대방사능은, 비교적 간편한 헌탁측정(suspension counting) 만으로 가능하였다. 본방법은 완두 외에 다른 식물조직중 탄소-14 분석에도 쓰일 수 있다.

  • PDF

액체섬광계수법을 이용한 방사성탄소 연대측정법 연구 (Study on the Radiocarbon Dating with Liquid Scintillation Counting)

  • 김낙배;우형주;홍완;조수영
    • 분석과학
    • /
    • 제5권4호
    • /
    • pp.381-387
    • /
    • 1992
  • 액체섬광계수법을 방사성탄소 연대측정에 이용하기 위하여 섬광용액과 섬광용액 대 벤젠의 부피비, 그리고 베타선 스펙트럼 측정범위를 변화시키면서 삼중수소의 영향을 최소화하고 최대 FOM을 얻기 위한 저준위 액체섬광계수기의 최적계측조건을 결정하였다. 결정된 조건하에서 백그라운드 계수율을 $2.26{\pm}0.03cpm$ 까지 낮출 수 있었으며, 이때의 최대 측정가능 연대는 약 40,000년에 이르렀다. 또한 고개시료 및 토탄시료 등의 실제시료에 적용하여 측정계의 실용성을 확인하였다.

  • PDF

Development of Movable Detection System for Efficiency Measurement in 3-PM Liquid Scintillation Counting

  • Hwang, H-Y;Kwak, S.I;Cho, Y.H;Byun, J.I;Lee, H.Y;Seo, J.S;Kwak, J.Y;Lee, J.M;Lee, K.B;Park, T.S;Chung, K.H;Lee, C.W
    • Nuclear Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.165-170
    • /
    • 2003
  • We developed an improved 3-PM liquid scintillation counting (3-PM LSC) method in which three detectors can be displaced to back and forth directions, and a data acquisition system being able to provide the values for all parameters required for the method. The detectors are entirely located in a 20-mm lead chamber of an inner diameter of 500 mm. A saw-toothed gear ties up all detectors so as to move them uniformly, up to 50 mm with unit of 1 mm. The data acquisition system was designed in an integrated circuit to perform the necessary works such as fast amplification, discrimination, coincidence and logic analysis. It generates values of nine parameters among twelve's generated in the 3-PH LSC method. The dead time of each counting channel is of extending type, valving from 10 to 100 $mutextrm{s}$. We measured the TDCR values with an unquenched liquid scintillation source 1"C by displacing the detectors with a step of 2.5 mm away from counting vial. Their values were derived on the range from 0.9 to 0.6. The extent is three times wider than those regions observed by applying the defocalization technique.ique.

A comparative study of different radiometric methodologies for the determination of 226Ra in water

  • Al-Hamarneh, Ibrahim F.;Almasoud, Fahad I.
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.159-164
    • /
    • 2018
  • An evaluation of various radiometric methods to analyze $^{226}Ra$ in water has been employed on a set of 10 standard solutions of different concentrations in the range of $1-10Bq/L^{-1}$. The analysis was carried out using well-established procedures by means of gamma-ray, alpha-particle and liquid scintillation spectrometry. The feasibility of the various methods has been quantified in terms of relative standard error and percentage error. Correlations between the various methods have been presented and discussed. In general, good agreement was found in the results of various methodologies, which assures the accuracy of the methods and allows for the validation of instrumentation and procedures. Of the different methods adopted here, a combined procedure for the determination of $^{226}Ra$ along with $^{228}Ra$ using Quantulus 1220 ultra-low level background liquid scintillation counting gave the most accurate results.

$^14C$년대측정을 위한 벤젠 합성 및 액체섬광계측의 최적 조건 (Optimum conditions of benzene synthesis and liquid scintillation counting fir radiocarbon dating)

  • 강형태;나경임
    • 보존과학연구
    • /
    • 통권15호
    • /
    • pp.21-32
    • /
    • 1994
  • Optimum conditions for benzene synthesis and liquid scintillation counting have been studied for the determination of radiocarbon age. In benzene synthesis the carbon dioxide converted to benzene with high efficiency of 91%. Yields of each step with 10L of carbon dioxide were $CO_2$ $\rightarrow$$C_2H_2$(94%), $C_2H_2$$\rightarrow$$C_6H_6$(96%) and$CO_2$$\rightarrow$$C_6H_6$(91%), respectively. Benzene synthesized from oxalate was measured with purity of 95% by GC /MS. $\delta^13$(C$^13$C/$^12$C) of oxalate was measured to $-24.7\{textperthousand}$ by massspectrometer. For liquid scintillation counting of benzene sample low background and highest FOM were measured in 0.5 ml cocktail and 3 ml standard solution with the range of 15.4∼74.9 KeV window setting. Oxalate and background samples weremeasured to $28.7\pm0.12$cpm and $3.92\pm0.04$ cpm in 15.4∼74.9 KeV

  • PDF

첼렌코프광과 액체섬광계수법을 이용한 89Sr 및 90Sr 분석에 대한 연구 (A Study on the Analysis of 89Sr and 90Sr with Cerenkov Radiation and Liquid Scintillation Counting Method)

  • 이명호;조영현;정근호;최근식;이창우
    • 분석과학
    • /
    • 제15권1호
    • /
    • pp.20-25
    • /
    • 2002
  • 추출크로마토그래피와 액체섬광계수기를 이용하여 기존의 방사성 스트론튬 분석법 단점을 해결하는 신속하고 신뢰성 있는 $^{89}Sr$$^{90}Sr$ 분석법을 개발하였다. 옥살산 공침혹은 양이온 교환수지로 방해원소를 제거한 후 Sr-spec 컬럼을 사용하여 스트론튬만을 순수분리한 후, 액체섬광계수기를 사용하여 $^{89}Sr$에서 방출하는 첼렌코프광을 측정하였고 spectrum unfolding 방법으로 $^{90}Sr$을 정량하였다. 본 연구에서 개발된 방사성 스트론튬 분석법을 환경 표준시료 (IAEA-375, Soil) 및 액체 폐기물시료에 적용하여 분석법의 유효성을 검증하였다.

액체섬광계수기를 이용한 환경시료중 $^{241}Pu$분석 (Determination of $^{241}Pu$ in Environmental Samples Using Liquid Scintillation Counting System)

  • 이명호;홍광희;최용호;김상복;최근식;이창우
    • Journal of Radiation Protection and Research
    • /
    • 제21권2호
    • /
    • pp.91-98
    • /
    • 1996
  • 알파방출핵종 존재하에 베타방출핵종인 $^{241}Pu$ 최적 분석조건을 검토하였다. 펄스파고 분석기법을 이용하여 PSA 준위를 설정하였다. $^{241}Pu$ 표준선원을 이용하여 figure of merit가 최대가 되도록 $^{241}Pu$ counting channel를 조정하였고 계측효율이 최대가 되도록 형광체 부피를 설정하였다. 최적화된 $^{241}Pu$ 분석법을 토양과 이끼등의 환경시료에 적용하여 $^{241}Pu$ 방사능농도를 측정하였고. $^{241}Pu/^{239,\;240}Pu$ 방사능 비율로부터 우리나라의 일부 토양 및 이끼에 침적된 Pu의 근원을 규명하였다.

  • PDF

Tritium radioactivity estimation in cement mortar by heat-extraction and liquid scintillation counting

  • Kang, Ki Joon;Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3798-3807
    • /
    • 2021
  • Tritium extraction from radioactively contaminated cement mortar samples was performed using heating and liquid scintillation counting methods. Tritiated water molecules (HTO) can be present in contaminated water along with water molecules (H2O). Water is one of the primary constituents of cement mortar dough. Therefore, if tritium is present in cement mortar, the buildings and structures using this cement mortar would be contaminated by tritium. The radioactivity level of the materials in the environment exposed to tritium contamination should be determined for their disposal in accordance with the criteria of low-level radioactive waste disposal facility. For our experiments, the cement mortar samples were heated at different temperature conditions using a high-temperature combustion furnace, and the extracted tritium was collected into a 0.1 M nitric acid solution, which was then mixed with a liquid scintillator to be analyzed in a liquid scintillation counter (LSC). The tritium extraction rate from the cement mortar sample was calculated to be 90.91% and 98.54% corresponding to 9 h of heating at temperatures of 200 ℃ and 400 ℃, respectively. The tritium extraction rate was close to 100% at 400 ℃, although the bulk of cement mortar sample was contaminated by tritium.

방사선 계측기의 품질관리 및 최소검출방사능 측정 (Quality Control of Radiation Counting Systems and Measurement of Minimum Delectable Activity)

  • 송병철;한성심;김영복;지광용;손세철
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.419-424
    • /
    • 2004
  • 방사성 폐기물 중에 함유된 핵종 및 방사능을 측정하기 위해서는 여러 가지 방사선 계측기가 이용되고 있다. 본 연구에서는 각각의 핵종에 대하여 측정 가능한 검출기를 선정하고 원전 방사성폐기물 중 방사능을 측정 하기위한 시스템을 구성하였다. 그리고 그 계측 시스템의 바탕 값 및 계측효율을 주기적으로 측정하고 품질관리를 위한 관리도를 작성하여 계측기의 안전성을 확보하고 분석결과에 대한 신뢰도를 향상시키고자 하였다. Gamma spectrometer의 바탕 값 평균은 1.59 cps이었으며 표준 시료에 대한 평균값은 45,248 dps로 거의 대부분의 측정값이 $2{\sigma}$ 이내에서 크게 벗어나지 않음을 나타냈다. Low background ${\alpha}/{\beta}$ counting 시스템의 알파 바탕 값 평균은 0.31 cpm이고 알파선 계측효율은 34.38% 이었으며, 베타 바탕 값은 1.3 cpm이고 베타선 계측효율 46.5% 이었다. 또한 액체섬광계수기는 3H 영역에서 바탕 값이 2.52 cpm, 계측효율 58.5% 이었으며, 14C 영역에서의 바탕 값은 3.31 cpm 이었고 계측효율은 95.6% 이었다. 본 연구에서는 바탕 값 및 계측효율로부터 최소검출방사능을 설정함으로써 시료의 측정 가능한 범위를 구하였다. 측정결과, gamma spectrometer의 최소검출방사능은 3.2 Bq/$m\ell$이었으며, ${\alpha}/{\beta}$counting 시스템의 경우는 알파 및 베타 영역에서 각각 20.5 Bq/$m\ell$, 23.0 Bq/$m\ell$이고 liquid scintillation counter의 경우는 3.8 Bq/$m\ell$로 나타났다.

  • PDF