• Title/Summary/Keyword: Liquid Metal Flow

Search Result 151, Processing Time 0.025 seconds

Pulsed Amperometric Detection of Metal Ions Complexing with EDTA in a Flow Injection System

  • 이준우;여인형;편종홍
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.3
    • /
    • pp.316-318
    • /
    • 1997
  • A general and universal detection method, which can be used in high performance liquid chromatography (HPLC) and flow injection analysis (FIA) system for the determination of any metal ions complexing with ethylenediaminetetraacetic acid (EDTA), is demonstrated. Pulsed amperometric detection scheme is applied in a flow-through thin layer electrochemical cell at an Au working electrode. Fluctuation of peak current level at the same flow rate of carrier solution is minimized at this solid working electrode, whereas not at a dropping mercury electrode. Removal of dissolved oxygen can be omitted with this detection method, which is a required step for cathodic detection methods. Also, a group of metal ions can be determined selectively and indirectly with this detection scheme.

A Study on the Elution Behavior of some Metal-N-Alkylisonitrosoacetylacetone imine Chelates by Reversed Phase High Performance Liquid Chromatography (역상 액체 크로마토그래피에 의한 몇 가지 금속-N-Alkylisonitrosoacetylacetone imine 킬레이트의 용리거동에 관한 연구)

  • Kim, Yong Jun;Kewon, Ji Hae;Lee, Won
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.63-71
    • /
    • 1992
  • Liquid chromatographic behavior of Pd(II), Ni(II) and Co(III) in N-Alkylisonitrosoacetylacetone imine(HIAA-NR) chelates was investigated by reversed phase high perfomance liquid chromatography. The optimum conditions for the separation of IAA-NR-metal chelates were examined respect to the flow rate and mobile phase strength. The metal-N-Alkylisonitrosoacetylacetone imine chelates in solution were successfully separated on Novapak $C_{18}$ column using acetonitrile/water mixture as mobile phase. The elution order of chelates is methyl>ethyl>propyl>butyl as N-alkyl group for ligand is varied. It was found that all IAA-NR-metal chelates were eluted in an acceptable range of capacity factor value($0{\leq}log\;k^{\prime}{\leq}1$). The dependence of log k' on the volume fraction of water in the binary mobile phase was examined. Also, the dependence of k' on the liquid-liquid extraction distribution ratio(Dc) in acetonitrile-water-alkane extraction system was investigated for IAA-NR-metal chelate. Both kinds of dependence are linear, which suggests that the retention of the electroneutral metal chelates on Novapak $C_{18}$ column is largely due to the hydrophobic effect.

  • PDF

Flow and Convective Heat Transfer Analysis Using RANS for A Wire-Wrapped Fuel Assembly

  • Ahmad, Imteyaz;Kim, Kwang-Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.9
    • /
    • pp.1514-1524
    • /
    • 2006
  • This work presents the three-dimensional analysis of flow and heat transfer performed for a wire-wrapped fuel assembly of liquid metal reactor using Reynolds-averaged Wavier-Stokes analysis in conjunction with 557 model as a turbulence closure. The whole fuel assembly has been analyzed for one period of the wire-spacer using periodic boundary conditions at inlet and outlet of the calculation domain. Three different assemblies, two 7-pin wire-spacer fuel assemblies and one bare rod bundle, apart from the pressure drop calculations for a 19-pin case, have been analyzed. Individual as well as a comparative analysis of the flow field and heat transfer have been discussed. Also, discussed is the position of hot spots observed in the wire-spacer fuel assembly. The flow field in the subchannels of a bare rod bundle and a wire-spacer fuel assembly is found to be different. A directional temperature gradient is found to exist in the subchannels of a wire-spacer fuel assembly Local Nusselt number in the subchannels of wire-spacer fuel assemblies is found to vary according to the wire-wrap position while in case of bare rod bundle, it's found to be constant.

CFD ANALYSIS OF HEAVY LIQUID METAL FLOW IN THE CORE OF THE HELIOS LOOP

  • Batta, A.;Cho, Jae-Hyun;Class, A.G.;Hwang, Il-Soon
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.656-661
    • /
    • 2010
  • Lead-alloys are very attractive nuclear coolants due to their thermo-hydraulic, chemical, and neutronic properties. By utilizing the HELIOS (Heavy Eutectic liquid metal Loop for Integral test of Operability and Safety of PEACER$^2$) facility, a thermal hydraulic benchmarking study has been conducted for the prediction of pressure loss in lead-alloy cooled advanced nuclear energy systems (LACANES). The loop has several complex components that cannot be readily characterized with available pressure loss correlations. Among these components is the core, composed of a vessel, a barrel, heaters separated by complex spacers, and the plenum. Due to the complex shape of the core, its pressure loss is comparable to that of the rest of the loop. Detailed CFD simulations employing different CFD codes are used to determine the pressure loss, and it is found that the spacers contribute to nearly 90 percent of the total pressure loss. In the system codes, spacers are usually accounted for; however, due to the lack of correlations for the exact spacer geometry, the accuracy of models relies strongly on assumptions used for modeling spacers. CFD can be used to determine an appropriate correlation. However, application of CFD also requires careful choice of turbulence models and numerical meshes, which are selected based on extensive experience with liquid metal flow simulations for the KALLA lab. In this paper consistent results of CFX and Star-CD are obtained and compared to measured data. Measured data of the pressure loss of the core are obtained with a differential pressure transducer located between the core inlet and outlet at a flow rate of 13.57kg/s.

Numerical simulation of three-dimensional flow and heat transfer characteristics of liquid lead-bismuth

  • He, Shaopeng;Wang, Mingjun;Zhang, Jing;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1834-1845
    • /
    • 2021
  • Liquid lead-bismuth cooled fast reactor is one of the most promising reactor types among the fourth-generation nuclear energy systems. The flow and heat transfer characteristics of lead-bismuth eutectic (LBE) are completely different from ordinary fluids due to its special thermal properties, causing that the traditional Reynolds analogy is no longer recommended and appropriate. More accurate turbulence flow and heat transfer model for the liquid metal lead-bismuth should be developed and applied in CFD simulation. In this paper, a specific CFD solver for simulating the flow and heat transfer of liquid lead-bismuth based on the k - 𝜀 - k𝜃 - 𝜀𝜃 model was developed based on the open source platform OpenFOAM. Then the advantage of proposed model was demonstrated and validated against a set of experimental data. Finally, the simulation of LBE turbulent flow and heat transfer in a 7-pin wire-wrapped rod bundle with the k - 𝜀 - k𝜃 - 𝜀𝜃 model was carried out. The influence of wire on the flow and heat transfer characteristics and the three-dimensional distribution of key thermal hydraulic parameters such as temperature, cross-flow velocity and Nusselt number were studied and presented. Compared with the traditional SED model with a constant Prt = 1.5 or 2.0, the k - 𝜀 - k𝜃 - 𝜀𝜃 model is more accurate on predicting the turbulence flow and heat transfer of liquid lead-bismuth. The average relative error of the k - 𝜀 - k𝜃 - 𝜀𝜃 model is reduced by 11.1% at most under the simulation conditions in this paper. This work is meaningful for the thermal hydraulic analysis and structure design of fuel assembly in the liquid lead-bismuth cooled fast reactor.

Study for Permanent Mold Design Technology and Porosity Defect Prediction Method by Multi-Phase Flow Numerical Simulations (다상유체해석을 통한 기포결함 예측과 금형설계기술)

  • Choi Y. S.;Cho I. S.;Hwang H. Y.;Choi J. K.;Hong J. H.
    • Transactions of Materials Processing
    • /
    • v.14 no.3 s.75
    • /
    • pp.224-232
    • /
    • 2005
  • The high-pressure die-casting is one of the most effective methods to produce a large amount of products in short cycle time. This process, however, has a problem that the gas porosity defect appears easily. The generation of gas porosity is known mainly due to the air entrapment during the injection stage. Most of numerical simulations for the molten metal flow pattern observations have done in the treating of one phase fluid flow but the gas-liquid interface is essentially multi- phase phenomenon. In this paper, the two-phase fluid flow numerical simulation methods have been adapted to predict the gas porosity generations in the molten metal. The accuracy and the usefulness of the new simulation module have been emphasized and verified through some comparison experiments.

Studies on the Elution Behavior and the Simultaneous Analysis of Some Metal-Dithiocarbamate Chelates by Reversed-Phase High Performance Liquid Chromatography (역상 액체 크로마토그래피에 의한 몇가지 금속-Dithiocarbamate 킬레이트의 용리거동 및 동시분석에 관한 연구)

  • Dai Woon Lee;Yun Je Kim;Hyun Chul Kim;Won Lee
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.211-226
    • /
    • 1988
  • Liquid chromatographic behavior of several metal ions in dithiocarbamate(DTC) chelates were investigated by reversed phase high performance liquid chromatography on Novapak $C_{18}$ and ${\mu}$-Bondapak $C_{18}$ columns. The optimum conditions for the separation of DTC-metal chelate were examined with respect to the pH, shaking time, flow rate, extraction solvent, and mobile phase strength. The metal ions in mixtures at trace level, chelated with some dithiocarbamate derivatives were separated successfully on Novapak $C_{18}$ column using acetonitrile/methanol/water or acetonitril/water mixtures as mobile phases. It was found that all DTC metal chelates studied were eluted in an acceptable range of capacity factor values ($0{\leqq}log\;k'{\leqq}1$). Although several foreign metal ions were coexisted, high recovery and good precision were attained ; 97.0-106.7 % for the recovery and 0.98-3.41% for the coefficient of variation. Under the optimum analytical conditions, trace metal ions in the composite water samples were determined sucessfully with in relative error of about {\pm}$6.7 %.

  • PDF