• Title/Summary/Keyword: Liquid Length

Search Result 886, Processing Time 0.024 seconds

The Flow of a Liquid Film on Spin Coating (스핀 코팅에서의 액막의 흐름)

  • Kim, Tae-sung
    • Journal of ILASS-Korea
    • /
    • v.18 no.3
    • /
    • pp.146-154
    • /
    • 2013
  • The flow of a liquid film on spin coating is investigated in the case that the fixed volume of a liquid is placed on the center of a stationary disk. Thin film equations that are well approximated when the characteristic length in the vertical direction is much smaller than that in the radial direction (${\varepsilon}{\ll}1$) and have already been proposed in the work of T.-S. Kim & M.-U. Kim (2009), are used. The differential equation that governs the free surface of a liquid when ${\varepsilon}{\ll}1$ and ${\varepsilon}Re{\ll}1$ is also derived. The basic flow is analyzed using the thin film equations and their results are compared to the results of Navier-Stokes equations.

Synthesis of Three Ring Type Compounds with Fluorine and NCS Groups as Candidates for VA mode Liquid Crystal Display

  • Heo, E.Y.;Kim, Y.B.;Kim, S.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.571-574
    • /
    • 2003
  • Three ring type liquid crystalline compounds having 4-alklycyclohexyl group, 1,2-difluorobenzene and phenylisothiocyanate moieties as main skeleton were designed to have negative dielectricity. However, the compounds with 2,3,2'-trifluoro-3'-isothiocyanated biphenylcyclohexane core did not exhibit the nematic liquid crystalline phase because of two conformers by interaction of isothiocyanate and adjacent fluorine atoms. Also, 4-alkyl-2,2',3'-trifluoro-3-isothiocyanated biphenylcyclohexane core was designed expecting to have uniform conformers of isothiocyanate group. In the course of developing polyimides for VA mode LCD, we synthesized alkyl-3,5-diaminobenzene efficiently with various length of alkyl chains from commercially available di-t-butyl malonate and 3,5-dinitrobenzoyl chloride as starting material.

  • PDF

Plasticization of Domestic Wood Treated with Liquid Amonia(I)-Equipment and Preliminary Test (액체암모니아를 이용한 국산재의 가소화(I) -처리장치 및 기초실험)

  • 강호양
    • Journal of the Korea Furniture Society
    • /
    • v.11 no.2
    • /
    • pp.55-60
    • /
    • 2000
  • Liquid ammonia treatment known as the most effective Wood plasticization method, was applied to two typical domestic species, Pinus densiflora, Castanea crenata. Small specimens of 30mm width, 300mm length and two thicknesses, 5 or 10mm, were used. For 5mm thick Specimens, Pinus densiflora was quite well plasticized iker 4 hour liquid ammonia treatment, while Castanea crenata was not plasticized even after 4 hour treatment. Specimens of 10mm thick Pinus densiflora were hardly plasticized, but those with kerfs were bent somewhat easily, With the increase of liquid ammonia treatment time the thermal conductivity of Pinus densiflora increased, while that of Castanea crenata didn't Presteaming before liquid ammonia treatment didn't improve the plasticization of both species.

  • PDF

Hybrid-type stretchable interconnects with double-layered liquid metal-on-polyimide serpentine structure

  • Yim, Doo Ri;Park, Chan Woo
    • ETRI Journal
    • /
    • v.44 no.1
    • /
    • pp.147-154
    • /
    • 2022
  • We demonstrate a new double-layer structure for stretchable interconnects, where the top surface of a serpentine polyimide support is coated with a thin eutectic gallium-indium liquid metal layer. Because the liquid metal layer is constantly fixed on the solid serpentine body in this liquid-on-solid structure, the overall stretching is accomplished by widening the solid frame itself, with little variation in the total length and cross-sectional area of the current path. Therefore, we can achieve both invariant resistance and infinite fatigue life by combining the stretchable configuration of the underlying body with the freely deformable nature of the top liquid conductor. Further, we fabricated various types of double-layer interconnects as narrow as 10 ㎛ using the roll-painting and lift-off patterning technique based on conventional photolithography and quantitatively validated their beneficial properties. The new interconnecting structure is expected to be widely used in applications requiring high-performance and high-density stretchable circuits owing to its superior reliability and capability to be monolithically integrated with thin-film devices.

Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry

  • Lee, Ju-Yong;Lim, Sang-Soo;Moon, Myeong-Hee
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.65-68
    • /
    • 2011
  • The effects of column length and particle size on the efficiency of separation and characterization of phospholipids (PLs) are investigated using nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Since PLs are associated with cell proliferation, apoptosis, and signal transduction, it is of increasing interests in lipidomics to establish reliable analytical methods for the qualitative and quantitative profiling of PLs related to biomarker development in adult diseases. Due to the complexity of PLs, the preliminary separation of PLs is necessary prior to MS analysis. In this study, length of capillary column and the particle size of reversed phase ($C_{18}$) packing materials are varied to find a reliable condition for the high speed and high resolution separation using 8 PL standard mixtures. From experiments, it was found that a capillary column of nLC-ESI-MS-MS analysis for PL mixtures can be minimized to a 5 cm long pulled tip column packed with 3 ${\mu}m$ $C_{18}$ particles without losing resolution.

Experimental Study on the Spray Characteristics of Aerated Impinging Jets (기체주입 충돌제트의 분무특성에 관한 실험적 연구)

  • Lee, Keunseok;Yoon, Youngbin;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.24 no.4
    • /
    • pp.185-193
    • /
    • 2019
  • The effervescent atomizer is one of twin-fluid atomizers that aeration gas enters into bulk liquid and two-phase flow is formed in the mixing section. The effervescent atomizer requires low injection pressure and small amount of aeration gas, as compared to other twin-fluid atomizers. In this study, cold flow test was conducted to investigate the spray characteristics of aerated impinging jets. The present effervescent impinging atomizers were composed of the aerator device and like-on-like doublet impinging atomizer which had different impinging angles. To analyze the spray characteristics such as breakup length and droplet size distribution, the image processing technique was adopted by using instantaneous images at each flow condition. Non-dimensional parameters, induced by the homogeneous flow model, were used to predict the breakup length. The breakup length was decreased with the mixture Reynolds number and impinging angle increasing. The result of droplets showed that the size distribution was axisymmetric about the center of the injector and their diameter tended to decrease with increasing GLR.

Bubble Properties in Bubble Columns with Electrolyte Solutions (전해질용액 기포탑에서 기포특성)

  • Yoo, D.J.;Lim, D.H.;Jeon, J.S.;Yang, S.W.;Kang, Y.
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Bubble properties such as size (chord length) and rising velocity were investigated in a bubble column with electrolyte solutions, of which diameter was 0.152m and 2.5m in height, respectively. The size and rising velocity of bubbles were measured by using the dual electrical resistivity probe method. Effects of gas and liquid velocities and ionic strength of liquid phase on the size and rising velocity of bubbles were determined. The bubble size increased with increasing gas velocity but decreased with increasing liquid velocity or ionic strength of liquid phase. The rising velocity of bubbles increased with increasing gas velocity and decreased with increasing ionic strength of liquid phase, however, it showed a slight maximum value with varying liquid velocity. The size and rising velocity of bubbles were well correlated with operating variables.

Prediction of Flow Rate and Drop Size of Low Viscosity Liquid Through Y-Jet Atomizers (Y-Jet노즐을 통한 저점도 액체의 유량 및 입경예측에 관한 연구)

  • 송시홍;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3377-3385
    • /
    • 1994
  • This paper introduces empirical correlations to obtain the gas/liquid flow rates and the spray drop size of low viscosity liquid injected by Y-jet twin-fluid atomizers. The gas flow rate is well correlated with the gas injection pressure and the mixing point pressure, based on the compressible flow theory. Similarly, the liquid flow rate is determined by the liquid injection pressure and the mixing point pressure, and a simple correlation for the liquid discharge coefficient at the liquid port was deduced from the experimental results. The mixing point pressure, which is one of the essential parameters, was expressed in terms of the gas/liquid flow rate ratio and the mixing port length. Disintegration and atomization mechanisms both within the mixing port and outside the atomizer were carefully re-examined, and a "basic" correlation form representing the mean diameter of drops was proposed. The "basic" correlation was expressed in terms of the mean gas density within the mixing port, gas/liquid mass flow rate ratio and the Weber number. Though the correlation is somewhat complicated, it represents the experimental data within an accuracy of ${\pm}15%$.EX>${\pm}15%$.

Change of Spray Characteristics with Mixing Port Length of Y-Jet Atomizers (Y-Jet 노즐에서의 혼합관 길이변화에 따른 분무특성 연구)

  • 송시홍;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3021-3031
    • /
    • 1994
  • Experiments have been performed to find out the effect of the mixing port length of Y-jet atomizers on the spray performance, using air and water as the test fluids. Water and air flow rates and drop sizes were measured at each injection pressure condition for different mixing port length. The air flow rate was almost unaffected by the change of the mixing port length. However, the water flow rate was relatively susceptible to the change of the mixing port length. The mixing point pressure was very much influenced by the mixing port length. Variations of spatial distribution of Sauter Mean Diameter (SMD, $D_{32}$) and the cross-section-averaged SMD ($D_{32,m}$) with different mixing port length and air/water mass flow rate ratio were examined. Generally, when the mixing port length was reduced, the mean drop size decreased and became spatially even.

Study on Atomization Characteristics of Shear Coaxial Injectors (전단동축형 분사기들의 미립화 특성에 대한 연구)

  • Ahn, Jonghyeon;Lee, Keunseok;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.26 no.1
    • /
    • pp.9-17
    • /
    • 2021
  • Six shear coaxial injectors with different recess length and taper angle were manufactured. Cold-flow tests on the injectors were performed at room temperature and pressure using water and air as simulants. By changing the water mass flow rate and air mass flow rate, spray images were taken under single-injection and bi-injection. Breakup length and spray angle were analyzed from instantaneous and averaged spray images using image processing techniques. For all the injectors, the breakup length generally decreased as the momentum flux ratio increased at the same gas mass flow rate. The injectors with 7.5° taper angle usually had the longest breakup length and the smallest spray angle. When the taper angle was 15° or more, it hardly affected breakup length and spray angle. The recess length did not influence breakup length but its effect on spray angle depended on the taper angle.