Studies on Simplified Procedures for Freezing and Thawing of Bovine Embryos VII. Effects of freezing procedures in a liquid nitrogen container on the survival rate of mouse embryos (육우수정란 간역동결 및 융해방법에 관한 연구 제칠보. 내동제에 Sucrose 첨가에 따른 액체질소에 미치는 영향)

  • 김중규;강만종;김영훈;장덕지;강민수;김승호
    • Korean Journal of Animal Reproduction
    • /
    • v.12 no.2
    • /
    • pp.84-90
    • /
    • 1988
  • This study was done with mouse embryos to determine effects of the freezing media with or without 10% sucrose, and seeding methods (pincette, no seeding, liquid nitrogen gas phase and copper wire coiled straw) on embryo survival were determined using the FDA test. The summarized results are the following. 1. The FDA score found with copper wire coiled straw, no seeding, pincette and liquid nitrogen gas phase was 3.6, 3.6, 3.3 and 3.0, respectively. There were no significant differences. 2. The embryo score shows higher (P<0.05) survival rate using a freezing medium with sucrose than the one without it. Among the seeding procedure, better resutls are copper wire coiled straw and no seeded. 3. The results suggest that copper wire coiled seeding no seeding be as good as seeding when the mouse embryos were frozen in a liquid nitrogen container using both the freezing and dilution media containing 10% sucrose.

  • PDF

Analytic Analysis of Liquid-Filled Membrane Container Resting on Horizontal Foundation with Given Cross-Sectional Volume (수평 지반에 놓인 액체 저장용 막구조물 형상의 단면 체적에 따른 해석적 해)

  • Choi, Yoon-Rak
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.62-66
    • /
    • 2011
  • In this paper, a liquid-filled long membrane container resting on a horizontal foundation is considered. All of the quantities are normalized to obtain similarity solutions. A system of nonlinear ordinary differential equations with undetermined boundary conditions is solved analytically. The integration of the curvature gives the solutions, which are expressed in terms of the elliptic integrals. A method for finding the shape and characteristic values is proposed for a given cross-sectional volume. The validity of these solutions is confirmed, and some results are shown for characteristic values and shapes.

The Content of Macrominerals in Beverages, Liquid Teas, and Liquid Coffees (유통 음료, 액상차 및 액상커피의 다량무기질 함량)

  • Kim, Sung-Dan;Moon, Hyun-Kyung;Park, Ju-Sung;Yang, Hye-Ran;Yi, Yun-Jeong;Han, Eun-Jung;Lee, Young-Chul;Shin, Gi-Young;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.8
    • /
    • pp.1134-1143
    • /
    • 2012
  • The aims of this study were to investigate some macrominerals (Na, Ca, P, K, Mg) in 207 beverages, 19 liquid teas, and 24 liquid coffees. The samples were digested by microwave and determinations of macrominerals were carried out by an Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES). The elements, listed in order of mean value of macromineral content, were potassium $208.4{\pm}298.2mg/L$ ($72.2{\pm}169.8mg/container$)> calcium $89.0{\pm}161.0mg/L$ ($26.0{\pm}57.7mg/container$)> sodium $71.2{\pm}75.0mg/L$ ($20.9{\pm}27.9mg/container$)> phosphorus $55.6{\pm}91.9mg/L$ ($17.9{\pm}33.8mg/container$)> magnesium $6.1{\pm}18.4mg/L$ ($2.4{\pm}10.1mg/container$). All 250 samples contained sodium and potassium, and the detection rate of calcium, phosphorus and magnesium was 88.4%, 93.2%, and 20.4%. The mean ratio of phosphorus to calcium in beverages, liquid teas, and liquid coffees was $4.2{\pm}16.0$ (ND~164.4), and sports drinks showed the highest mean ratio ($48.5{\pm}75.6$) significantly (p<0.05). In case of sodium, detected content exceeding labeling regulations (less then 120%) was observed in 12 samples (5.5%).

Performance Test of a Tuned Liquid Mass Damper installed in a Real-Scaled Structure (실물크기 구조물에 설치된 동조액체질량감쇠기의 성능실험)

  • Heo, Jae-Sung;Park, Eun-Churn;Lee, Sang-Hyun;Lee, Sung-Kyung;Min, Kyung-Won;Kim, Hong-Jin;Jo, Ji-Seong;Cho, Bong-Ho;Joo, Seok-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.449-457
    • /
    • 2008
  • In this paper, a tuned liquid1) mass damper(TLMD) was proposed and experimentally investigated on its control performance, which can control bi-axial responses of building structures by using only one device. The proposed TLMD controls the structural response in a specific one direction by using a liquid sloshing of TLCD. Also, the TLMD reduces the response of structures in the other orthogonal direction by behaving as a TMD that uses mass of the container itself and liquid within container of TLCD installed on linear motion guides. Force-vibration tests on a real-sized structure installed with the TLMD were performed to verify its independent behavior in two orthogonal directions. Test results showed that the responses of a structure were considerably reduced by using the proposed TLMD and its usefulness for structural control in two orthogonal directions.

  • PDF

Analytical comparison of structural changes of plastic cell-based therapeutic drug storage containers when exposed to cryogenic environments (플라스틱 세포치료제 보관용기의 극저온 환경 노출 시 구조적 변화에 대한 해석적 비교)

  • Park, Jeong-Yeon;Lee, Dong-Mok;Lee, Jienny;Lee, Sun-ray;Yoon, Gil-Sang
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.1-6
    • /
    • 2020
  • Recently, research and commercialization related to the field of cell-based therapeutic drug development has been actively conducted. In order to maintain cell viability and prevent contamination, refrigeration preservation devices, such as CRF (controlled rate freezer) or vapor type LN2 tanks have been developed. On the other hand, the storage container for liquid nitrogen tanks currently on sale minimizes the flow structure to prevent structural defects when stored in a liquid nitrogen tank having a high thermal conductivity than vapor nitrogen. If the cell-based treatment drug is stored in the gaseous LN2 tank as it is, the cell survival after thawing is greatly reduced. It was estimated that the existing storage container structure was a factor that prevented the rapid entry and circulation of gaseous nitrogen into the container. Therefore, this study intends to propose a new supercellular storage container model that can maintain the mechanical strength while maximizing the fluid flow structure. To this end, we estimated that the structural change of the storage container effects on the equivalent stress formed around the through-holes of them when exposed to a cryogenic environment using thermal-structural coupled field analysis. As a result of storage experiments in the gas phase tank of the cell-based therapeutic agent using the developed storage container, it was confirmed that the cell growth rate was improved from 66% to 77%, which satisfied the transportation standards of the FDA(Food and Drug Administration) cell-based therapeutic agent.

Sloshing characteristics of an annular cylindrical tuned liquid damper for spar-type floating offshore wind turbine

  • Jeon, S.H.;Seo, M.W.;Cho, Y.U.;Park, W.G.;Jeong, W.B.
    • Structural Engineering and Mechanics
    • /
    • v.47 no.3
    • /
    • pp.331-343
    • /
    • 2013
  • The natural sloshing frequencies of annular cylindrical TLD are parametrically investigated by experiment, aiming at the exploration of its successful use for suppressing the structural vibration of spar-type floating wind turbine subject to multidirectional wind, wave and current excitations. Five prototypes of annular cylindrical TLD are defined according to the inner and outer radii of acryl container, and eight different liquid fill heights are experimented for each TLD prototype. The apparent masses near the first and second natural sloshing frequencies are parametrically investigated by measuring the apparent mass of interior liquid sloshing to the acceleration excitation. It is observed from the parametric experiments that the first natural sloshing frequency shows the remarkable change with respect to the liquid fill height for each TLD model with different container dimensions. On the other hand, the second natural sloshing frequency is not sensitive to the liquid fill height but to the gap size, for all the TLD models, convincing that the annular cylindrical sloshing damper can effectively suppress the wave- and wind-induced tilting motion of the spar-type floating wind turbine.

A New Aluminium Container for $\gamma$-Ray Spectrometry Analysis of Radium and Radon (라듐 및 라돈의 감마선 분광 분석을 위한 알루미늄 용기의 제작 및 특성 조사)

  • Lee, Kil Yong;Yoon, Yoon Yeol;Seo, Bum Kyoung
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.743-750
    • /
    • 2000
  • For the ${\gamma}$-ray spectrometry analysis of radium and radon in environmental samples, plastic Marinelli beakers have been usually used. But, there are two problems; one is the increment of background by adsorption of airborne radon daughters on the plastic beaker, and other is the incompleteness of radioactive equilibrium by the loss of gaseous radon produced during the radioactive equilibrium process. In order to solve these problems, we made aluminium counting container, and investigated its characteristics. We investigated radioactive equilibrium process using the aluminium container. We found that both solid and liquid samples reached at radioactive equilibrium state in the aluminium container without loss of gaseous radon. By the use of the aluminium container, we established radon and radium analysis method of solid and liquid samples using gamma-ray spectrometry.

  • PDF

Internal Pressure Variation Analysis and Actual Holding Time Test on ISO LNG Tank Container (LNG 탱크 컨테이너의 내부압력 변화 분석 및 실제 홀딩타임 측정)

  • Ryou, Young-Don;Lee, Jin-Han;Jo, Young-Do;Oh, Young-Sam;Cha, Kyong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.1-7
    • /
    • 2013
  • Internal pressure variation analysis and actual holding time test on ISO LNG tank containers which were made in Korea for the first time according to the special notification of ISO tank container manufacture have been conducted during the transport demonstration projects of the tank containers by tractor, train and ship. The internal pressure of the LNG tank container increased rapidly after LNG filling and dropped during moving the container. However, it was stabilized as time passed and followed the liquid-vapor equilibrium graph. In addition, actual holding time of the tank container was more than 20 days which was satisfied with the special notification of LNG tank container manufacture.