코발트-60 감마선의 전자 오염에 관한 연구 (Study on the Reduction of Electron Contamination with A Cobalt-60 Gamma Ray)

  • 김태규;전하정;이명자
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.293-297
    • /
    • 1989
  • Electron contamination due to the interaction between radiation beam and material was analyzed for the factors such as source-skin distance (SSD), field size, tray characteristics and position of filter, which can affect the surface dose in Cobalt teletherapy. Surface dose in open beam was more influenced by SSD with increasing field size. Relative surface charge (RSC) increased with the use of tray (solid, circular hole, slotted), compared with open beam, which is thought to be due to increased electron contamination of the tray. To reduce the surface dose, 0.4mm thick Lipowitz metal filter was used. Compared with open beam, RSC decreased by 8.8%, 11.3%, 13.3%, 16.6%, 19.3% and 21.7% for the field size of $5{\times}5$, $10{\times}10$, $15{\times}15$, $20{\times}20$, $25{\times}25$ and $30{\times}30cm^2$, respectively. On the contrary, use of Lipowitz metal filter increased RSC at 60cm or less SSD. Surface dose was effectively reduced with Lpowitz metal filter placed right below solid tray in Cobalt teletherapy.

  • PDF

Mevatron KD 67-7467의 변형조사면에 대한 전자선 선량측정 (Electron Dosimetry of Shaped Fields on Mevatron KD 67-7467)

  • U Hong;Samuel Ryu;H. D. Kang
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.109-122
    • /
    • 1990
  • 전자선 치료에 있어서 조사면을 부분적으로 차폐할 수 있는 차폐체 제작 방법을 제시하였다. Lipowitz 합금으로 만든 차폐체는 표준 Siemens cone에 적합하며, 조사면의 평탄도는 차폐체에 의한 영향을 거의 받지 않았다. 그러나 개방 조사면에 대한 차폐 조사면의 비가 0.7 이상이면 차폐체에 의한 선량의 차이가 있음을 알았다. Biggs 등이 제안한 Cone ratio는 차폐 조사면의 Cone ratio curve가 개방조사면의 Cone ratio를 따르지 않기 때문에 본 연구에서는 Cone ratio를 Cone factor와 Insert ratio로 나누어 차폐 조사면에 대한 선량 변화를 넓게 측정하였다.

  • PDF

Quasi-Conformation 치료를 위한 새로운 방사선치료기술의 개발 (Development of a New Radiotherapy Technique using the Quasi-Conformation Method)

  • 최태진;김진희;김옥배
    • Radiation Oncology Journal
    • /
    • 제9권2호
    • /
    • pp.343-350
    • /
    • 1991
  • 종양모양에 거의 일치하는 선량분포를 얻기위해 다층부정형필터를 이용하는 방법을 보였으며, 필터의 재질은 Lipowitz (일명 cerrobend alloy) 금속체를 이용하였다. 선속내 필터의 놓임은 일차선의 감쇄와 함께 조직내 산란선 기여율의 변화가 예상되므로 필터의 두께에 따른 SMR의 변화가 계산에 이용되어야 된다. 이에 본 연구의 계산선량은 실측치의 $3\%$이내에서 잘 일치됨을 알 수 있었다. 다층부정형필터를 이용한 펜톰의 원호조사의 선량평 가는 동일 필터에 의한 고정조사의 선량분포가 적용되었으며, 가상종양에 거의 일치하는 선량분포를 얻을수 있었다. 한편, 컴퓨터모의계산된 선량과 열발광산량계(teflon-embedded TLD)의 실측선량은 비교적${\pm}5\%$ 범위내에서 잘 일치됨을 알 수 있었으며, 이 치료방법은 현재 차폐체로 많이 이용되고 있는 Lipowitz 금속체를 사용함으로써 보다 쉽게 응용되어질 것으로 생각된다.

  • PDF

6 MV 광자선조사면내 투과성필터에 의한 조직선량 (Scatter Dose in soft tissue using the partial attenuation filter for 6 MV X-ray of linear accelerator)

  • 최태진;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제4권1호
    • /
    • pp.55-71
    • /
    • 1993
  • Measured and calculated the TMR and SMR factors from percent depth dose underpartial attenuators which cover the whole part of the radiation beam with variousfilter thickness from 0 to 50 mm. This study was performed for x-ray beams generated with a 6 MV linear acceleratorat source to surface distance of 100cm in a water phantom for Lipowitz metal. TMR(0,d,t) was derived from non-linear polynomial regression with field sizedifferencies and a given filter thickness. In this experiments, the TMR(0,10,50) of 50mm of filter thickness was showed13.6 % higher than that of open field and SMR(5,10,50) was 38.5% smaller than thatof open field in same depth.

  • PDF

선형가속기 ML-15MDX의 각 Applicator에 대한 전자선 출력선량 계수 결정 (Determination of Electron Beam Output Factors of Individual Applicator for ML-15MDX Linear Accelerator)

  • Park, Tae-Jin;Kim, Ok-Bae
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.87-99
    • /
    • 1994
  • 목적 : 선형가속기 ML-15MDX의 전자선에너지 대한 출력선량계수가 Applicator크기에 따라 결정되도록 하며 각 Applicator에서 정방형조사면과 직사각형조사변에 대한 출력선량계수는 측정값으로 부터 다항식을 이용하여 결정되었다. 방법 : 실험에서, 출력선량의 측정은 전자선에너지 4, 6, 9, l2MEV대해 2$\times$2$cm^2$에서 20$\times$20$cm^2$까지 이루어졌다. 출력선량계수는 각 아프리케이터의 조사면중심선속의 최대선량에 대한 임의 조사면의 최대선량의 비로 얻어졌고 각 아프리케이터의 출력선량계수는 기준 아프리케이터(10$\times$10$cm^2$)와 비교되었다. 전자선조사면의 차폐는 모든 실험에너지 영역에서 균등하게 10mm 두께의 Lipowitz(밀도 9.4g/$cm^2$)를 사용하였으며, 조사면크기 및 모양 결정이 용이하도록 고안하여 사용되었다. 임의의 전자선조사면에 대한 출력선량계수는 조사면의 한변을 고정한 직사각형의 출력선량 계수를 이용한 1-Dimension방법에 의한 다항식으로 부터 구하였다. 결과 : 직사각형의 전자선조사면에 대한 출력선량계수는 4$\times$4$cm^2$에서 20$\times$20$cm^2$의 범위에서는 2%이내의 불확실성을 보였으며, 이들 보다 작은 직사각형조사면에서는 약 3%의 오차를 보였다. 결론 : 전자선에너지의 정사각형 및 직사각형조사변에 대한 출력선량계수가 실험자료를 이용한 다항식으로 부터 실제값에 매우 근사한 예상값을 얻을 수 있었다.

  • PDF

방사선 치료용 전자선의 에너지별 납(Pb) 차폐체 두께 측정 (A Study on the Lead(Pb) Shield Thickness per Electron Beam Energy in Radiotherapy)

  • 김가중
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.719-725
    • /
    • 2022
  • 본 연구는 임상에서 이용되는 전자선 빔의 에너지별 차폐를 위한 최소한의 납 두께를 측정하여 정량적으로 평가하고 기준을 설정하고자 한다. 전자선 에너지별 납 차폐체의 두께는 최대선량 깊이(dmax)와 조직선량의 기준 깊이인 표면 10 mm 깊이에서 개방 조사야를 기준으로 1차선속의 95%로 감소시킬 수 있는 납 두께를 측정하였다. 측정 결과 6 MeV 전자선의 납 차폐체 두께는 최대선량 깊이에서 1.906 mmPb, 조직선량 기준깊이(10 mm)에서 1.992 mmPb로 나타났으며, 9 MeV 전자선은 2.746 mmPb, 3.743 mmPb, 12 MeV 전자선은 3.718 mmPb, 6.093 mmPb, 16 MeV 전자선은 7.300 mmPb, 15.270 mmPb, 20 MeV 전자선은 16.825 mmPb, 25.090 mmPb로 측정 깊이를 조직선량 기준깊이로 할 때 더 두꺼운 납 차폐체가 필요하였다. 또한 16 MeV 이상의 전자선은 이론식보다 더 두꺼운 납 차폐체가 요구된다.