• Title/Summary/Keyword: Linked Facilities

Search Result 198, Processing Time 0.036 seconds

A Study on the Analysis of Positional Accuracy between the GPR Survey Data and Underground Space Integration Map (현장 GPR 탐사자료와 지하공간통합지도 상호위치 정확도 분석에 관한 연구)

  • SONG, Seok-Jin;CHO, Hae-Yong;HAN, Dam-Hye;KIM, Sung-Gil
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.4
    • /
    • pp.208-216
    • /
    • 2020
  • Recently, issues regarding underground safety such as sink hole, ground subsidence and damage to old underground facilities have been increasing in urban areas, raising the need for more accurate management of underground facilities. Thus, this study derived a technique for comparing spatial data of underground facilities acquired from GPR exploration results acquired at the site with spatial data of integrated underground spatial maps. Using this underground space integrated map-linked service prototype program developed through this study, comparing the location information of the GPR exploration results and the underground space integrated map for the verification of site usability in some sections around Gangnam Station, the results demonstrated that the location of the map is 0.879m maximum, minimum of 0.101m and the average fudge factor was 0.625m. If accuracy of the GPR exploration results is guaranteed, it is judged that it can be used to improve the location accuracy of the underground space integration map.

Planning Directions for Parks and Green Spaces in Future Industrial Complexes according to Changes in the Industrial Environment (산업환경 변화에 따른 미래형 산업단지의 공원녹지 계획방향에 관한 연구)

  • Lee, Eun-yeob;Lee, Hyeon-Ju;Kim, Tae-Gun;Choi, Dae-Sik;Song, Young-il
    • Journal of Environmental Science International
    • /
    • v.30 no.2
    • /
    • pp.109-118
    • /
    • 2021
  • Due to changes such as those stemming from the onset of the fourth industrial revolution, it is expected that industrial complexes will transform from being spacious structures into smaller, integrated complexes. Green parks, which are also a type of infrastructure within industrial complexes, also require planned direction suited to the changing environment. The planned directions of green parks in new industrial complexes were examined and surveys were conducted on industrial complex workers. Preferred functional arrangement, importance, and satisfaction levels of green ratios, preference of compound facilities linked to parks, appropriate dimensional greening methods were all surveyed across 1,035 businesses. Results of the survey exhibited that there was high awareness on the importance of building green areas, but it was found that current greenery levels were insufficient. There was a high rate of responses indicated that dimensional greening is required in building-type industrial spaces, and preferences for rooftop greenery, stair-type greenery, and atrium greenery were also high. There were many opinions that it is necessary to integrate cultural facilities, exhibition and educational facilities, commercial facilities, parking lots in parks. Furthermore, it was found that it is necessary to provide pathways for bikes and pedestrians, rather than those for vehicles, and to connect them with the green parks. This study stopped short of exploring the directions for which green parks should aim in new industrial complexes with changes in the industrial environment. In the future, more concrete plans on green park planning techniques according to the spatial characteristics and structures of new industrial complexes will be necessary.

Plans for the Integrated Operation of Intelligent Service Facilities (지능화시설의 통합운영 방안)

  • YIM, Du-Hyun;PARK, Jeong-Woo;NAM, Kwang-Woo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.1
    • /
    • pp.127-136
    • /
    • 2017
  • U-City laws are divided into three categories: intellectual laws, information superhighway laws, and integrated operation center laws. Previous studies have suggested that efficient infrastructure operation and management is necessary in Ubiquitous-City (U-City). However, infrastructure is often interpreted differently by different laws. The purpose of this study was to plan for the integrated operation of intelligent service facilities by comprehensively analyzing the law system of domestic intelligent service facilities and problems in operation and management based on this critical mind. For this, present conditions and problems of intelligent service facilities were found through interviews with people who are in charge of the law system and other practitioners. The necessity of integrated use, including city information generated from intelligent service facilities and installment locations, has been demonstrated. Government ministries and local governments have established various information systems using ICT and U-City laws that specify integrated management and operation, but do not clearly specify definitions for the specific responsibility and authority for main agents participating in facility operation. A system is needed to smoothly mediate the relevant divisions so that they can use installed equipment simultaneously for efficient operation in generating city information. This objective of this study was to prepare a unitary law system for efficient installment and management of intelligent service facilities by establishing a logically linked relationship among the relevant laws and regulations. This will provide a foundation for a management system that has an integrated linkage of intelligent service facilities.

Analysis of Proper Linked Treatment Load Using GPS-X Simulation (GPS-X 시뮬레이션을 이용한 적정 연계처리부하량 분석)

  • Kim, Sungji;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.244-250
    • /
    • 2019
  • Due to the industrial development and population growth, it has recently been shown that there are many problems caused by the rinked treatment water in local goverments and sewage treatment plants. The rinked treatment water has a characteristic of low flow rate and high concentration unlike general sewage. These characteristics increase sewage treatment difficulty and sewage treatment fee of sewage treatment facilities. Among the many influencing factors that increase sewage treatment unit cost, 'linked treatment load/design inflow load (%)' was derived as the most correlated factor. Through the selection and modeling of sewage treatment plants, the excess scope of design discharge water quality was investigated under the conditions of temperature and the conditions of 'linked treatment load/design inflow load (%)' taking into account the effects of the four seasons. The study found that for TN, 'linked treatment load/design inflow load (%)' was 19.7%, 22.6%, 25.1%and 27.7%, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$. In case of TP, 'rinked treatment load/design inflow load (%)' was 10.7%, 12.2%, 15.6% and 17.5% at $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$, and $25^{\circ}C$, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$.

A Plan to Provide Effective Risk Map Information by Linking a 3D Disaster Information Display System with an On-site Assistance Application (3D 재해 정보 표출시스템과 현장 지원 APP간의 연계를 통한 효과적인 Risk Map 정보제공 방안)

  • KIM, Do-Ryeong;GANG, Su-Myung;RYU, Dong-Ha;PARK, Ju-Sung;JO, Myung-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.1
    • /
    • pp.141-153
    • /
    • 2016
  • The increase in frequency and scale of natural disasters is the typical negative examples of the global climate change and the change of the human living environment in cities. The damage caused by natural disasters in particular including human and physical damage is directly linked to the safety and properties of citizens. Besides, the damage may occur to SOC facilities directly or indirectly. The SOC facilities damaged by disasters cause infringement of citizens safety rights. Therefore, a plan to provide prompt and effective risk map information by linking a 3D disaster information display system, which handles the information of the damage that may occur to SOC facilities such as bridges, beams, and dams at the time of disasters, with an on-site assistance application is suggested in this study. The prompt provision of risk map information is defined as a dynamic expression technology in this study. Also, disaster information is processed and compressed with a module developed to be linked organically to a system that displays disaster information, a proliferation system that can use the information on site, and a DB system that constructs a relationship with the information. Based on the module, the effective disaster information compression plan will be prepared, and the prompt information transmission system will be secured in the future.

GPR Exploration of Non-metallic Water Pipes Linked with Network RTK (네트워크 RTK와 연계한 비금속 상수관의 GPR 탐사)

  • Lee, Keun-Wang;Park, Joon-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.296-301
    • /
    • 2021
  • GPR is used for non-destructive investigations, ground investigations, and underground facilities exploration at construction sites. In this study, the applicability to GPR exploration of water pipes linked to Network RTK was presented. Data on the water supply pipes in the study site were acquired using GPR, and the location and depth of buried water pipes could be measured. The accuracy was evaluated from the GNSS observation performance and showed a deviation of -0.16m ~ 0.15m. This satisfied the equipment performance of the public survey work regulation, suggesting that the exploration of water pipes using GPR is possible. Because GPR does not require grounding installation, as in conventional metal pipe detectors, it will increase the efficiency of work for underground facility exploration. Exploration using GPR can acquire the location and depth of metallic and non-metallic underground facilities, so it can be utilized in the construction of a GIS system. If a comparison of the exploration characteristics is carried out, it will be possible to present various uses of underground facility exploration using GPR.

Analysis of Applicability of the Detention in Trunk Sewer for Reducing Urban Inundation (도시 내수침수 저감을 위한 간선저류지 적용성 분석)

  • Lee, Sung Ho;Kim, Jung Soo;Kim, Seo Jun
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.1
    • /
    • pp.44-53
    • /
    • 2021
  • The flood prevention capacity of drainage facilities in urban areas has weakened because of the increase in impervious surface areas downtown owing to rapid urbanization as well as localized heavy rains caused by climate change. Detention can be installed in trunk sewers and linked to existing drainage facilities for the efficient drainage of runoff in various urban areas with increasing stormwater discharge and changing runoff patterns. In this study, the concept of detention in trunk sewers, which are storage facilities linked to existing sewer pipes, was applied. By selecting a virtual watershed with a different watershed shape, the relationship between the characteristic factors of detention in the trunk sewer and the design parameters was analyzed. The effect of reducing stormwater runoff according to the installation location and capacity of the reservoir was examined. The relationship between the installation location and the capacity of the detention trunk sewer in the Dowon district of the city of Yeosu, South Korea was verified. The effects of the existing water runoff reduction facility and the detention trunk sewer were also compared and analyzed. As a result of analyzing the effects of reducing internal inundation, it was found that the inundation area decreased by approximately 66.5% depending on the installation location of the detention trunk sewer. The detention trunk sewer proposed in this paper could effectively reduce internal inundation in urban areas.

Network Modeling of Paddy Irrigation System using ArcHydro GIS (ArcHydro를 이용한 GIS기반의 관개시스템 네트워크 모델링)

  • Park, Geun-Ae;Park, Min-Ji;Jang, Jung-Seok;Kim, Seong-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.323-327
    • /
    • 2006
  • During the past decades in South Korea, there have been several projects to reduce water demand and save water for paddy irrigation system by automation. This is called as intensive water management system by telemetering of paddy ponding depth and canal water level and telecontrol of water supply facilities. This study suggests a method of constructing topology-based irrigation network system using GIS tools. For the network modeling, a typical agricultural watershed included reservoirs, irrigation and drainage canals, pumping stations was selected. ArcHydro tools composed of edge, junction, waterbody and watershed were used to construct hydro-network. ArcHydro Model was then designed and the network was successfully built using the HydroID. Visualization using ArcHydro tools could display table property of each object. ArcHydro Model was linked to Agricultural Water Demamd and Supply Estimation System (AWDS) which developed by Korea Rural Community and Agriculture Corporation (KRC) to extract information of the study area. And menu of supply facilities information, demand analysis and supply analysis constructed for information acquisition and visualization of acquired informations.

  • PDF

A Study on the Architectural Characteristics of the Mixed-use Buildings in the Residential Land Development District in country-side cities - Focused on Shin-Eum Housing district in Gimcheon - (중소도시 택지개발지구내 복합건축물의 건축적 특성에 관한 연구 - 김천시 신음택지지구를 중심으로 -)

  • Lee, Keun-Taek;Park, Kyoung-Hwan
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.127-136
    • /
    • 2006
  • The intent of this study is to propose future planning guidelines and directions of the mixed-use buildings in the residential land development district in country-side cities, based on the concept that the neighborhood facilities are to be strategically laid out in a convenient location and planned in a proper manner for a healthy, safe, friendly and new neighborhood environment. For this purpose, seventeen mixed-use buildings which had been built in Shin-Eum housing development district in Gimcheon from 1995 until 2004 were chosen and investigated in terms of architectural characteristics in that process with surveying and analyzing those. The scope of investigation on case studies was that site size would be below 400 square meters, total area below 1500 square meters, and the number of stories below five stories high on the ground. Method of investigation on those was through field investigation, field photographs, recordings and drawings on those. Investigative contents have been divided and analyzed into the quantitative and qualitative factors in urban and architectural dimension. From results of quantitative investigations, five planning guidelines or directions could be obtained. From results of qualitative investigations, five planning guidelines or directions could be obtained. The criteria will be applied to new architectural developments of the neighborhood facilities linked with the small shops.

A Study on the Design Direction for Special Education Class Area in Elementary Schools for Inclusive Education - Focused on the Sense of Place for Children in Special Education Class - (통합교육을 위한 초등학교 특수학급영역 설계방향에 관한 연구 - 특수학급 아동의 장소성을 중심으로 -)

  • Yoon, Dong-Hyun;Rieh, Sun-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.2
    • /
    • pp.3-12
    • /
    • 2014
  • Elementary School is a special facility where sense of place plays critical role for the development of children. Children in special education call for special attention as they hold inferior status compared to the children in regular class especially under the inclusive education policy. Eight cases of special education class area are analyzed in terms of social space, personal space and favorite place which is known to be basic factor for the development. As a result outdoor space found to be designed inappropriate even when designed accessible to the special education class as it could not meet the developmental needs of children in special education. Special education class area inside the building is also found to be too exclusive to allow social mix with children in regular class disregarding the intention of inclusive education. Location of these class should be strategic as it is critical to be linked with regular classroom efficiently still allowing psychological buffer as the children in special education tend to form restorative space inside the special education classroom showing the possibility of creating sense of place there.