• 제목/요약/키워드: Link switching

검색결과 462건 처리시간 0.028초

보조 공진 DC 링크 스너버형 컨버터와 3상 전압형 인버터의 전력손실분석 (Auxiliary resonant DC Link and power loss analysis of three phase voltage type inverter)

  • 김주용;문상필;김영문;이현우;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1064-1066
    • /
    • 2002
  • This paper proposes a new prototype auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually measured conduction loss characteristic of switching device module. Voltage type soft switching three phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

  • PDF

소프트-스위칭 고주파 링크 방식을 적용한 계통연계형 태양광 발전 시스템에 관한 연구 (Grid Connected PV System Based on High-Frequency Link With Soft - Switching)

  • 주연홍;이성룡;전칠환
    • 한국정보통신학회논문지
    • /
    • 제6권2호
    • /
    • pp.309-314
    • /
    • 2002
  • 본 논문은 계통연계형 태양광 발전 시스템에 고주파 링크 방식과 소프트-스위칭 방식을 적용하여 변압기와 스위칭 손실의 문제를 해결하기 위해 연구하였다. 그리고 각각의 주 전원 스위치가 소프트 스위칭을 하기 위해 위상천이 방식과 ZVT 방식을 적용하였다. 이로써 스위칭 주파수를 증가시킬 수 있고 고주파 변압기의 부피 및 무게를 감소시킬 수 있으며 시스템의 효율의 증대를 기대할 수 있는데 이를 시뮬레이션과 실험을 통하여 검증하였다.

A Novel Prototype of Duty Cycle Controlled Soft-Switching Half-Bridge DC-DC Converter with Input DC Rail Active Quasi Resonant Snubbers Assisted by High Frequency Planar Transformer

  • Fathy, Khairy;Morimoto, Keiki;Suh, Ki-Young;Kwon, Soon-Kurl;Nakaoka, Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.89-97
    • /
    • 2007
  • This paper presents a new circuit topology of active edge resonant snubbers assisted half-bridge soft switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed half-bridge high frequency PWM inverter with a high frequency planar transformer link in addition to input DC busline side power semiconductor switching devices for PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC buslines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, a high switching frequency IGBTs can be actually selected in the frequency range of 60 kHz under the principle of soft switching. The performance evaluations of the experimental setup are illustrated practically. The effectiveness of this new converter topology is proved for such low voltage and large current DC-DC power supplies as DC bus feeding from a practical point of view.

동력의지를 위한 BLDCM 구동 시스템 및 상전류 추정 기법 (A Brushless DC Motor Drive System and Phase Current Estimation Method For Active Knee Prothesis)

  • 남기준;최연범;정두희
    • 재활복지공학회논문지
    • /
    • 제7권2호
    • /
    • pp.7-12
    • /
    • 2013
  • 본 논문에서는 동력의지를 위한 브러쉬리스 DC 모터 구동 시스템과 DC 링크단의 전류를 이용하여 상전류를 추정하는 기법을 제안한다. 토크제어를 위해서는 전류 측정이 매우 중요하며 전류 측정 시 스위칭 노이즈를 최소화하기 위해 전류 센싱 시점은 스위칭 전압 명령에 동기화 되어야 한다. 저가의 시스템, 공간의 절약 그리고 제어의 단순화하기 위해 DC 링크단 전류를 사용한 제어를 실시하였다. 또한 환류 다이오드를 통해 흐르는 전류에서 발생하는 DC 링크단 전류와 상전류간의 오차를 줄이기 위해 Analog MUX를 이용한 상전류 추정방법을 사용하였다. 실험 결과를 통해 제안한 시스템의 유효성을 검증하였다.

  • PDF

Utility-Interactive Modulated Sinewave Inverter with a High Frequency Flyback Transformer Link for Small-Scale Solar Photovoltaic Generator

  • Konishi Y.;Chandhaket S.;Ogura K.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.683-686
    • /
    • 2001
  • This paper presents a novel prototype of the utility­interactive voltage source type sinewave pulse modulated power inverter using a high-frequency flyback transformer link. The proposed power conditioner circuit for the solar photovoltaic generation and small scale fuel cell has an isolation function due to the safety of the power processing system, which is more cost effective and acceptable for the small-scale distributed renewal energy conditioning and processing systems. The discontinuous current mode(DCM) of this power processing conversion circuit is applied to implement a simple circuit topology and pulse modulated control scheme. Its operation principle is described on the basis of simulation evaluations and theoretical considerations. The simulation results obtained herein prove that the proposed inverter outputs with sinusoidal waveforms and unity power factor currents are synchronized to the main voltage in utility power source grid. In this paper, the soft switching topology of high­frequency linked sinewave pulse modulation inverter is proposed and discussed.

  • PDF

The Ground Interface Concept of the KOMPSAT-II DLS

  • Lee, Sang-Taek;Lee, Sang-Gyu;Lee, Jong-Tae;Youn, Heong-Sik
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.228-228
    • /
    • 2002
  • The DLS(Data Link System) is located in the PDTS(Payload Data Transmission Subsystem) of KOMPSAT-II, and its main function is to provide communication link with Ground Segment as a space segment. DLS receive the data of MSC, OBC from DCSU(Data Compression Storage Unit) and transmit to the Ground Station by X-Band RF link. DLS is consist of CCU(Channel Coding Unit), QTX(QPSK Transmitter, ASU(Antenna Switch Unit) CCU makes a packet for communication after several kind of data processing such like Ciphering, RS Coding. QTX transmit PDTS data by OQPSK. Modulation. ASU is the unit for reliability of antenna switching. So, DLS's function is consists of ciphering, RS coding, CCSDS packetizing, randomizing, modulation and switching to antenna. These DLS's functions are controlled by PMU(Payload Management Unit). All commands to DLS are sent by PMU and all telemetries of DLS are sent to the PMU. The PMU receives commands from OBC and sends telemetries to the OBC. The OBC communicates with Ground Station by S-Band RF link. This paper presents the on-orbit DLS operation concept through the ground segment.

  • PDF

위상 천이 소프트 스위칭 PWM DC-DC 컨버터를 이용한 방전등 구동용 직류 전원장치 (DC Power Supply Driving Discharge Lamp Using PWM DC-DC Converter of Single- Phase Shift Soft Switching)

  • 이현우;정상화;권순걸;서기영
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.100-106
    • /
    • 2005
  • 일반적으로 자외선(UV)을 발생하기 위한 방전등 구동용 직류 전원장치는 하드 스위칭 모드로 동작되어지는 고주파 스위칭 DC-DC 컨버터가 사용되고 있다. 구체적으로 전원장치는 전자 노이즈 장해에 의한 전자 회로의 오동작이나 각 구성 소자의 발열의 문제 등이 시스템의 신뢰성을 저하시키는 원인이 되고 있다. 그러므로 본 논문에서는 소프트 스위칭 회로 기술을 사용한 고주파 링크 DC-DC 컨버터로서 먼저 구체적으로 1차측 위상 천이 PWM DC-DC 컨버터와 제안한 2차측 위상 천이 PWM DC-DC 컨버터를 조합하여 방전등 구동용 직류 전원장치를 제안하였다. 제안하는 방전등 구동용 직류 전원장치는 시뮬레이션과 실험을 통하여 그 타당성을 서술하였다.

전압원인버어터의 최적스위칭패턴 (Optimal Switching Pattern of Voltage Source Inverter)

  • 정필선;정동화;이윤종
    • 한국통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.386-398
    • /
    • 1987
  • 本 論文은 PWM(Pulse Width Modulation)인버어터의 스위칭作用에 의해서 發生하는 高周波 影響을 最小化하기 위한 Suboptimal PAWM(Pulse Amplitude Width Modulation)을 提示하였다. 本 方式은 Suboptimal PWM에서 THD(Total Harmonic Distorition)가 最小가 되는 固定點(基本波 電壓 u1=1.2)에서 하나의 스위칭패턴을 決定하였다. 그리고 電壓은 DC Link에서 DC Chopper에 의해 制御하게 하고 인버어터에서는 단지 高周波만을 制御하도록 하였다. 本 方式은 3相 誘導電動機의 VSD(Variable Speed Drive)에 適用하여 電動機의 騷音, 인버어터의 線間電壓 및 電流, 電流高周波 스펙트럼을 測定하였으며, 他 方式과 比較해 보았다. 그 結果로부터 本 方式의 妥當性을 立證할 수 있었다.

  • PDF

A Novel Bio-inspired Trusted Routing Protocol for Mobile Wireless Sensor Networks

  • Zhang, Mingchuan;Xu, Changqiao;Guan, Jianfeng;Zheng, Ruijuan;Wu, Qingtao;Zhang, Hongke
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권1호
    • /
    • pp.74-90
    • /
    • 2014
  • Routing in mobile wireless sensor networks (MWSNs) is an extremely challenging issue due to the features of MWSNs. In this paper, we present a novel bio-inspired trusted routing protocol (B-iTRP) based on artificial immune system (AIS), ant colony optimization (ACO) and Physarum optimization (PO). For trust mechanism, B-iTRP monitors neighbors' behavior in real time and then assesses neighbors' trusts based on AIS. For routing strategy, each node proactively finds routes to the Sink based on ACO. When a backward ant is on the way to return source, it senses the energy residual and trust value of each node on the discovered route, and calculates the link trust and link energy of the route. Moreover, B-iTRP also assesses the availability of route based on PO to maintain the route table. Simulation results show how B-iTRP can achieve the effective performance compared to existing state-of-the-art algorithms.