• Title/Summary/Keyword: Link cost

Search Result 601, Processing Time 0.028 seconds

Contact force Estimation in 2-link Robot Manipulator Using Extended Kalman Filters (확장된 칼만필터를 이용한 2축 로봇 매니퓰레이터의 접촉힘 추정)

  • 이중욱;허건수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.14-19
    • /
    • 2000
  • Recent requirements for the fast and accurate motion in industrial robot manipulator need more advanced control techniques. To satisfy the requirements, importance of the force control is being continuously increased and the expensive force sensor is usually installed to obtain the contact force information in practice. This information is indispensable for the force control of maintaining the desired contact force. However the sensor cost is too high to be used in industrial applications. In this paper, it is proposed to estimate the contact force occurred between the end-effector of 2 DOF robots and environment. The contact force estimation system is developed based on the static and dynamic models of 2 DOF robot manipulators, where the contact force is described with respect to the link torque. The Extended Kalman Filter is designed and its performance is verified in simulations.

  • PDF

Contact Force Estimation of Robot Manipulators in 3-D Space (3차원 공간상에서 로봇 매니퓰레이터의 접촉힘 추정)

  • Lee, Jung-Wook;Heo, Kun-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.2
    • /
    • pp.192-197
    • /
    • 2001
  • Recent requirements for the fast and accurate motion in industrial robot manipulators need more advanced control techniques. To satisfy the requirements, importance of the force control is being continuously increased and the expensive force sensor is often installed to obtain the contact force information in practice. This information is indispensable for the force control of maintaining the desired contact force. However, the sensor cost is too high to be used in industrial applications. In this paper, it is proposed to estimate the contact force occurred between the end-effector of robots and environment in 3-D. The contact force monitoring system is developed based on the static and dynamic models of 3 DOF robot manipulators, where the contact force is described with respect to the link torque. The Extended Kalman Filter is designed and its performance is verified in simulations.

A High Efficiency Single-Stage PFC Flyback Converter for PDP Sustaining Power Module (PDP 유지 전원단을 위한 고효율 Single-stage PFC Flyback Converter)

  • Yoo, Kwang-Min;Lim, Sung-Kyoo;Lee, Jun-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.3 s.16
    • /
    • pp.11-16
    • /
    • 2006
  • A low cost PDP sustain power supply is proposed based on flyback topology. By using Boundary Conduction Method(BCM) to control input current regulation, DCM condition can be met under all load conditions. Another feature of the proposed method is that a excessive voltage stress due to the link voltage increase can be suppressed by removing link capacitor and suggest new 'Level-shifting switch driver'. this new gate driver is improved 66% of efficiency than switching loss of a existed push-pull amplifier. The proposed converter is tested with a 400W(200V-2A output) prototype circuit.

  • PDF

Optimal Antenna Selection Scheme with Transmit Adaptive Array for Wideband CDMA Systems

  • Kim, Hak-Seong;Kim, Sanhae;Lee, Woncheol;Yoan Shin
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1960-1963
    • /
    • 2002
  • Transmit diversity schemes we an effective capacity improvement method for down link of wideband code division multiple access (W-CDMA) systems. In this paper, we propose to use transmit antenna subset selection scheme in conjunction with closed loop transmit adaptive array (TxAA). The proposed scheme selects N$\_$s/ optimum antennas among N$\_$${\gamma}$/(>N$\_$s/) transmit antennas in order to maximize diversity gain from selected antennas, and also reduces the cost of RE chains by employing two different types of RF modules fur the selected and the unselected antenna group, respectively. Computer simulation results show performance improvement by the proposed scheme over the conventional TxAA when considering up link control information feedback.

  • PDF

Utility Interactive Inverter with High-frequency Link for Photovoltaic Power System (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.W.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1050-1052
    • /
    • 2000
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system (3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation. a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Various Algorithms of Service Recovery in IP Network (IP 네트워크 상의 다양한 서비스 복구 알고리즘)

  • Han, Jeong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9B
    • /
    • pp.791-798
    • /
    • 2004
  • In case of failure in the IP network, services should be provided via a backup path which fully meets QoS requirements. In this regard, we in this paper suggest simple-PFC(s-PFC) to restore single link failure, iterative-PFC(i-PFC) for multiple link failures, and fault_node Avoidance-PFC(a-PFC) for failures of nodes such as routers. Taking the minimum cost rerouting problem into account, we compare and analyze performance of those three mechanisms carrying out Direct-destination Rerouting(DR).

Performance Enhancement of Spread Spectrum LEO Satellite communication System Using Constant Modulus Antenna Array

  • Lee, Byung-Seub
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • The structure of MMSE receiver front-ended by CMA(Constant Modulus Array) array working in CDMA forward link which is applicable to LEO spread spectrum satellite communication system is proposed. By using the despreaded pilot signal of forward link as a reference signal, the CMA array can capture multi-path signals securely even in severely faded LEO satellite channel. The remaining MAI (Multiple Access Interference) is cancelled by the cascaded MMSE receiver. Besides theoretical development, through relevant computer simulation, it is proved that the proposed system shows much better BER performance than any other possible candidate systems. As a spatio-temporal receiver mounted on a mobile vehicle, the proposed system also reduces implemental cost and complexity by adopting the simplest algorithm for its spatial and temporal domain processing.

High-Frequency DC Link Inverter for Grid-connected PV System (계통연계형 태양광발전시스템을 위한 고주파 DC 링크 인버터)

  • Jung Young-Seok;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.46-49
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kVA) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kVA high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier. four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

A simple method to optimize DC-bus capacitor in 3-phase shunt Active power filter system

  • Phan, Dang-Minh;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.367-368
    • /
    • 2015
  • This paper introduces a shunt active power filter with a small DC bus capacitor by adding additional low-pass filter (LPF). The DC link voltage fluctuation is impressively suppressed with a small value in spite of the low value of DC-link capacitor under the steady-state condition. Consequently, the cost and volume of power converter are significantly reduced thanks to the reduced value of DC-bus capacitor. On the other hand, an indirect control strategy is used to maintain grid-side current when non-linear loads are connected to the system. By using proportional-integral (PI) and modified repetitive controller (RC) in dq0 frame, the calculation time is greatly decreased by 6 times compared with the conventional RC, and the number of measurement devices is also minimized. As a result, the acquired total harmonic distortion (THD) is lower than 2% regardless of the load conditions. Simulation results are carried out in order to verify the effectiveness of the proposed control strategy.

  • PDF

Design for Low Cost Optical Node with Wavelength Reconfiguration

  • Lee, Jong-Hyung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.63-68
    • /
    • 2022
  • Two wavelength reconfigurable optical nodes are designed. One for 20km or shorter link length, and the other for up to 60km link length. While the first one requires no dispersion compensation, the latter needs dispersion compensation fiber included in the node, which requires additional optical amplifier to compensate the insertion loss of DCF. We calculate all the optical path losses in both cases using the typical value of optical components in the market to see the feasibility of the designed optical node. The minimum received power in the node is calculated to be -21.5dBm without DCF and -12.5dBm with DCF, respectively. These received powers are above the receiver sensitivity both for OC-48 and OC-192 according to the previous work.