• 제목/요약/키워드: Link Load

Search Result 563, Processing Time 0.03 seconds

Optimal Load Balancing On SONET Rings with Integer Demand Splitting (정수단위로만 루팅이 허용되는 SONET 링의 용량결정문제)

  • 명영수
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.23 no.3
    • /
    • pp.49-62
    • /
    • 1998
  • In the ring loading problem, traffic demands are given for each pair of nodes in an undirected ring network with n nodes and a flow is routed in either of the two directions, clockwise and counter-clockwise. The load of a link is the sum of the flows routed through the link and the objective of the Problem is to minimize the maximum load on the ring. In the ring loading problem with integer demand splitting, each demand can be split between the two directions and the flow routed in each direction is restricted to integers. Recently, Vachani et al. [INFORMS J. Computing 8 (1996) 235-242] have developed an Ο(n$^3$) algorithm for solving this integer version of the ring loading problem and independently, Schrijver et al. [to appear in SIAM J. Disc. Math.] have presented an algorithm which solves the problem with {0,1} demands in Ο(n$^2$|K| ) time where K denotes the index set of the origin-desㅇtination pairs of nodes having flow demands. In this paper, we develop an algorithm which solves the problem in Ο(n |K|) time.

  • PDF

Study for the Controller Design of a Direct Drive Servo Valve (직접구동형 서보밸브의 제어기 설계에 관한 연구)

  • 이성래;김종열;김치붕
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.136-136
    • /
    • 2000
  • The direct drive servo valve(DDV) is composed of a DC rotor, link, valve spool and displacement sensor(LVDT) where the spool is directly coupled to the DC motor through the link. Since the DDV is a kind of one-stage valve, the robust controller is required to overcome the flow force effect on the spool motion. The mathematical equations are derived and the stability, accuracy and response speed of a DDV are investigated analytically using a linearized system block diagram. Proportional control, PID control. Time-Delay control, Sliding Mode control, and Proportional control using the load pressure are applied to DDV to find which one shows the best control performance. The digital computer simulation results show that the proportional control using the load pressure satisfies the design requirement of response speed and steady state error regardless of the variation of load pressure,

  • PDF

Three-Phase Four-Wire Inverter Topology with Neutral Point Voltage Stable Module for Unbalanced Load Inhibition

  • Cai, Chunwei;An, Pufeng;Guo, Yuxing;Meng, Fangang
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1315-1324
    • /
    • 2018
  • A novel three-phase four-wire inverter topology is presented in this paper. This topology is equipped with a special capacitor balance grid without magnetic saturation. In response to unbalanced load and unequal split DC-link capacitors problems, a qusi-full-bridge DC/DC topology is applied in the balance grid. By using a high-frequency transformer, the energy transfer within the two split dc-link capacitors is realized. The novel topology makes the voltage across two split dc-link capacitors balanced so that the neutral point voltage ripple is inhibited. Under the condition of a stable neutral point voltage, the three-phase four-wire inverter can be equivalent to three independent single phase inverters. As a result, the three-phase inverter can produce symmetrical voltage waves with an unbalanced load. To avoid forward transformer magnetic saturation, the voltages of the primary and secondary windings are controlled to reverse once during each switching period. Furthermore, an improved mode chosen operating principle for this novel topology is designed and analyzed in detail. The simulated results verified the feasibility of this topology and an experimental inverter has been built to test the power quality produced by this topology. Finally, simulation results verify that the novel topology can effectively improve the inhibition of an inverter with a three-phase unbalanced load while decreasing the value of the split capacitor.

Priority Based Medium Access Control and Load Balancing Scheme for Shared Situational Awareness in Airborne Tactical Data Link (공중 전술 데이터링크에서 상황인식 공유를 위한 우선순위 기반 매체접속제어와 부하분산 기법)

  • Yang, Kyeongseok;Baek, Hoki;Park, Kyungmi;Lim, Jaesung;Park, Ji Hyeon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.10
    • /
    • pp.1210-1220
    • /
    • 2016
  • As modern warfare has changed into network centered, the ability to share situational awareness among allies become a core competency for performing operational missions. In an airborne environment, it uses a tactical data link such as Link-16 for shared situational awareness. There exist problems when it shares situational awareness over the existing data link that can not allocate slots dynamically or that can not change the number of a slot to be allocated. In addition, there was a problem that can not share this failure so that failed to improves situation awareness because of finite time slot resources. In this paper, we accommodate dynamic slot allocation and changes of slot allocation with mixed structure of TDMA (time division multiple access) and random access. We propose a technique that can be used when available slots are exhausted, and a load balancing method to prevent slot allocation delay when slot requesting or message sending is concentrated on a single subframe.

Advanced Frame Distribution Method Using Padding for Link Aggregation between 10GbE Switches

  • Lee Soong-Hee;Jeon Hyoung-Goo
    • Journal of information and communication convergence engineering
    • /
    • v.3 no.1
    • /
    • pp.13-17
    • /
    • 2005
  • The link e daggregation between 10GbE switches requires an advanced framistribution method to be properly and efficiently applied. The fixed or dynamic frame distribution methods, formerly proposed, cannot fully utilize the aggregated links, where the receiving terminal only attaches to a pre-specified link among multiple physical links. A frame distribution method using padding is proposed for the link aggregation between 10GbE switches to solve this problem. We compared the performance of the proposed method with those of the static and dynamic frame distribution methods. As a result, the proposed method shows a better performance when the offered load is below 0.7 and the average length of the frames is longer than 954 bytes.

Position Control of the Two Links Inverted Pendulum with a Time Varying Load on the Top (상부 시변 부하를 갖는 2축 도립진자의 위치 제어)

  • 이건영
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1147-1153
    • /
    • 1999
  • The attitude control of a double inverted pendulum with a periodical disturbance at link top is dealt in this paper. The proposed system is consisted of the double inverted pendulum and a disturbing link; a triple inverted pendulum with two motors. The lower link is hinged on the plate to free for rotation in the vertical plane. The upper link is connected to the lower link through a DC motor. The DC motor is used to control the posture of the pendulum by adjusting the position of the upper link. The periodical disturbance can be generated by the additional like attached at the end of link 2 through another DC motor, which is the modeling of a posture for a biped supporting with one leg. The motor for the joint simulates the knee joint(or hip joint) and the disturbance for the legs moving in air. The algorithm for controlling the proposed inverted pendulum which is regarded as a virtual double inverted pendulum with a periodic disturbance, is consisted of a state feedback control and a fuzzy logic controller connected in parallel. The fuzzy controller keeps the center of gravity of the biped within the specified range through the nonlinear feedback compensator. The state feedback control takes over the role to maintain a desired posture regardless the disturbance at the link top. Simulations with a mathematical model and experiments are conducted to show the validity of the proposed controller.

  • PDF

Effect of link length in retrofitted RC frames with Y eccentrically braced frame

  • INCE, Gulhan
    • Steel and Composite Structures
    • /
    • v.43 no.5
    • /
    • pp.553-564
    • /
    • 2022
  • Many existing reinforced concrete (RC) structures need to be strengthening for reason such as poor construction quality, low ductility or designing without considering seismic effects. One of the strengthening methods is strengthening technique with eccentrically braced frames (EBFs). The characteristic element of these systems is the link element and its length is very important in terms of seismic behavior. The link element of Y shaped EBF systems (YEBFs) is designed as a short shear element. Different limits are suggested in the literature for the link length. This study to aim experimentally investigate the effect of the link length for the suggested limits on the behavior of the RC frame system and efficiency of strengthening technique. For this purpose, a total of 5 single story, single span RC frame specimens were produced. The design of the RC frames was made considering seismic design deficiencies. Four of the produced specimens were strengthened and one of them remained as bare specimen. The steel YEBFs were used in strengthening the RC frame and the link was designed as a shear element that have different length with respect to suggested limits in literature. The length of links was determined as 50mm, 100mm, 150mm and 200mm. All of the specimens were tested under cyclic loads. The obtained results show that the strengthening technique improved the energy consumption and lateral load bearing capacities of the bare RC specimen. Moreover, it is concluded that the specimens YB-2 and YB-3 showed better performance than the other specimens, especially in energy consumption and ductility.

The Load Current Observer Design for Torque Control of DC Meter (직류 전동기의 속도 토크 제어를 위한 부하 전류 관측기 설계)

  • Seo Young-Soo;Kim Eun-Gi;Kim Yong-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.155-158
    • /
    • 2001
  • In this paper, the Load Current Observer Design for 3-phase Voltage Type PWM Converter with DC Meter Load. The sinusoidal input current and unity input power factor are realised based on the estimated source voltage performed by the Load Current Observer using actual currents and DC link voltage.

  • PDF

Zone-Based Wireless Link-K Network Structure and Routing for Supporting Mission Group (작전임무그룹 지원을 위한 Zone 기반 무선 Link-K 네트워크 구조 및 라우팅)

  • Cheon, Minhwan;Baek, Hoki;Jee, Seungbae;Kim, Sangjun;Lim, Jaesung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.1
    • /
    • pp.108-120
    • /
    • 2017
  • To this end, the ROK military is developing a Korean Tactical Data Link (Link-K) in two stages: Basic and Completion types. Currently, the basic type of the Link-K has a limitations for supporting Mission Group(MG)s, such as to share unnecessary information and inefficient routing, because all RICCs simply broadcasts the same information in the basic type of the Link-K. In this paper, we propose a Zone-based Wireless Link-K network structure and a routing algorithm. To improve the effectiveness of the proposed routing algorithm, we have studied a filtering method that adjusts the message data according to the priority of the message and a method of controlling the load of the network. In order to evaluate the performance of the proposed scheme, it is proved that it is effective to support the mission task group compared with the existing wireless Link-K routing algorithm according to the operational scenario situation.

Development of a Multi-link VPN Load Balancing Technology (다중링크 VPN 분하균등 기술 개발)

  • 김정우;손주영
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.05b
    • /
    • pp.175-178
    • /
    • 2003
  • 현재 다중 링크VPN(Virtual Private Network) 장비들은 회선 장애(Fail-Off) 발생 시 회선 간의 전이(Transition) 기능만 가능할 뿐이고, 부하균등(Load Balancing)은 고려하지 않고 있다. 이럼으로써 다중 회선의 효율성이 크게 떨어지는 결과를 보인다. 본 논문에서는 부하균등을 하면서 회선장애 발생 시 전이되는 기술을 제안하였다.

  • PDF