• Title/Summary/Keyword: Linear stability limit

Search Result 107, Processing Time 0.025 seconds

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Fenoprofen in Human (페노프로펜 체내동태 연구를 위한 혈청 중 페노프로펜의 HPLC 정량법 개발 및 검증)

  • Cho, Hye-Young;Kang, Hyun-Ah;Kim, Yoon-Gyoon;Sah, Hong-Kee;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.6
    • /
    • pp.423-429
    • /
    • 2005
  • A selective and sensitive reversed-phase HPLC method for the determination of fenoprofen in human serum was developed, validated, and applied to the pharmacokinetic study of fenoprofen calcium. Fenoprofen and internal standard, ketoprofen, were extracted from human serum by liquid-liquid extraction with diethyl ether and analyzed on a Luna C18(2) column with the mobile phase of acetonitrile-3 mM potassium dihydrogen phosphate (32:68, v/v, adjusted to pH 6.6 with phosphoric acid). Detection wavelength of 272 nm and flow rate of 0.25 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed fenoprofen concentration $(2\;{\mu}g/mL)$ with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of $0.05-100\;{\mu}g/mL$ with correlation coefficients greater than 0.999. The lower limit of quantification using 1 mL of serum was $0.05\;{\mu}g/mL$, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 92.27 to 109.20% for fenoprofen with overall precision (% C.V.) being 5.51-11.71 %. The relative mean recovery of fenoprofen for human serum was 81.7%. Stability (freeze-thaw, short and long-term) studies showed that fenoprofen was not stable during storage. But, extracted serum sample and stock solution were allowed to stand at ambient temperature for 12 hr prior to injection without affecting the quantification. The peak area and retention time of fenoprofen were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of fenoprofen in human serum samples for the pharmacokinetic studies of orally administered Fenopron tablet (600 mg as fenoprofen) at three different laboratories, demonstrating the suitability of the method.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Pentoxifylline in Human Serum (체내동태 연구를 위한 혈청 중 펜톡시필린의 HPLC 정량법 개발 및 검증)

  • Cho, Hea-Young;Kang, Hyun-Ah;Yoo, Hee-Doo;Lee, Hwa-Jeong;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.2
    • /
    • pp.89-95
    • /
    • 2006
  • A selective and sensitive reversed-phase HPLC method for the determination of pentoxifylline in human serum was developed, validated, and applied to the pharmacokinetic study of pentoxifylline. Pentoxifylline and internal standard, chloramphenicol, were extracted from the serum by liquid-liquid extraction with dichloromethane and analyzed on a Luna CI8(2) column with the mobile phase of acetonitrile-0.034 M phosphoric acid (25:75, v/v, adjusted to pH 4.0 with 10 M NaOH). Detection wavelength of 273 nm and flow rate of 0.8 mL/min were used. This method showed linear response over the concentration range of 10-500 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of the serum was 10 ng/mL, which was sensitive enough for pharmacokinetic studies of pentoxifylline. The overall accuracy of the quality control samples ranged from 89.3 to 92.7% for pentoxifylline with overall precision (% C.V.) being 4.1-9.2%. The relative mean recovery of pentoxifylline for human serum was 105.8%. Stability (stock solution, short and long-term) studies showed that pentoxifylline was not stable during storage. But three freeze-thaw cycles and extracted serum samples were stable. This method showed good ruggedness (within 15% C.V.) and was successfully applied for the analysis of pentoxifylline in human serum samples for the pharmacokinetic studies of orally administered $Trental^{\circledR}$ tablet (400 mg pentoxifylline), demonstrating the suitability of the method.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Dipyridamole in Human (디피리다몰 체내동태 연구를 위한 혈청 중 디피리다몰의 HPLC 정량법 개발 및 검증)

  • Cho, Hea-Young;Kang, Hyun-Ah;Moon, Jae-Dong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.1
    • /
    • pp.45-51
    • /
    • 2006
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of dipyridamole in human serum was developed, validated, and applied to the pharmacokinetic study of dipyridamole. Dipyridamole and internal standard, loxapine, were extracted from human serum by liquid-liquid extraction with diethyl ether and analyzed on a Nova Pak $C_{I8}$ column with the mobile phase of 40 mM ammonium acetate:methanol:acetonitrile (35:35:30)(v/v/v, pH 7.8). Detection wavelength of 280 nm and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed dipyridamole concentration (50 ng/mL) with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 2-2000 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 2 ng/mL, which was sensitive enough for pharmacokinetic studies of dipyridamole. The overall accuracy of the quality control samples ranged from 103.94 to 105.86% for dipyridamole with overall precision (% C.V.) being 4.60-11.49%. The relative mean recovery of dipyridamole for human serum was 97.64%. Stability studies showed that dipyridamole was stable during storage, or during the assay procedure in human serum. The peak area and retention time of dipyridamole were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of dipyridamole in human serum samples for the pharmacokinetic studies of orally administered Dimor tablet (75 mg as dipyridamole) at three different laboratories, demonstrating the suitability of the method.

Development and Validation of HPLC Method for Pharmacokinetic Study of Promethazine in Human (염산프로메타진 체내동태 연구를 위한 혈청 중 프로메타진의 HPLC 정량법 개발 및 검증)

  • Cho, Hae-Young;Kang, Hyun-Ah;Lee, Hwa-Jeong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.1
    • /
    • pp.23-29
    • /
    • 2006
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of promethazine in human serum was developed, validated, and applied to the pharmacokinetic study of promethazine. Promethazine and internal standard, chlorpromazine, were extracted from human serum by liquid-liquid extraction with n-hexane containing 0.8% isopropanol and analyzed on a Capcell Pak CN column with the mobile phase of acetonitrile-0.2 M potassium dihydrogen phosphate (42:58, v/v, adjusted to pH 6.0 with 1 M NaOH). Detection wavelength of 251 nm and flow rate of 0.9 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed promethazine concentration (10 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 1-40 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 1 mL of serum was 1 ng/mL, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 96.15 to 105.40% for promethazine with overall precision (% C.V.) being 6.70-11.22%. The relative mean recovery of promethazine for human serum was 63.54%. Stability (freeze-thaw and short-term) studies showed that promethazine was stable during storage, or during the assay procedure in human serum. However, the storage at $-80^{\circ}C$ for 4 weeks showed that promethazine was not stable. Extracted serum sample and stock solution were not allowed to stand at ambient temperature for 12 hr prior to injection. The peak area and retention time of promethazine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of promethazine in human serum samples for the pharmacokinetic studies of orally administered Himazin tablet (25 mg as promethazine hydrochloride) at three different laboratories, demonstrating the suitability of the method.

Validated HPLC Method for the Pharmacokinetic Study of Atenolol and Chlorthalidone Combination Therapy in Korean Subjects

  • Kang, Hyun-Ah;Kim, Hwan-Ho;Kim, Se-Mi;Yoon, Hwa;Cho, Hea-Young;Oh, Seaung-Youl;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.5
    • /
    • pp.331-338
    • /
    • 2006
  • A rapid, selective and sensitive reverse-phase HPLC methods for the determination of atenolol and chlorthalidone in human serum and whole blood were validated, and applied to the pharmacokinetic study of atenolol and chlorthalidone combination therapy. Atenolol and an internal standard, pindolol, were extracted from human serum by liquid-liquid extraction, and analyzed on a $\mu$-Bondapak C18 $10-{\mu}$ column in a mobile phase of methanol-0.01 M potassium dihydrogenphosphate(30:70, v/v, adjusted to pH 3.5) and fluorescence detection(emission: 300 nm, excitation: 224 nm). Chlorthalidone and an internal standard, probenecid, were extracted form human whole blood by liquid-liquid extraction, and analyzed on a Luna C18 $5-{\mu}$ column in a mobile phase of acetonitrile containing 77% 0.01 M sodium acetate and UV detection at 214 nm. These analysis were performed at three different laboratories using the same quality control(QC) samples. The chromatograms showed good resolution, sensitivity, and no interference by human serum and whole blood, respectively. The methods showed linear responses over a concentration range of 10-1,000 ng/mL for atenolol and 0.05-20 ${\mu}g/mL$ for chlorthalidone, with correlation coefficients of greater than 0.999 at all the three laboratories. Intra- and inter-day assay precision and accuracy fulfilled international requirements. Stability studies(freeze-thaw, short-, long-term, extracted sample and stock solution) showed that atenolol and chlorthalidone were stable. The lower limit of quantitation of atenolol and chlorthalidone were 10 ng/mL and 0.05 ${\mu}g/mL$, respectively, which was sensitive enough for pharmacokinetic studies. These methods were applied to the pharmacokinetic study of atenolol and chlorthalidone in human volunteers following a single oral administration of Hyundai $Tenoretic^{\circledR}$ tablet(atenolol 50 mg and chlorthalidone 12.5 mg) at three different laboratories.

A Study on Configuration of the Road Guide Data Model for Visually Impaired Pedestrian (시각적 교통약자를 위한 길안내 데이터 모델 구축에 관한 연구)

  • Park, Sung Ho;Kwon, Jay Hyoun;Lee, Jisun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.2
    • /
    • pp.119-133
    • /
    • 2022
  • Due to the improvement of surveying, mapping and communication techniques, various apps for road direction guides and vehicle navigations have been developed. Although such a development has impacted on walking and driving, there is a limit to improving the daily convenience of the socially impaired people. This is mainly due to the fact that the software have been developed for normal pedestrians and drivers. Therefore, visually impaired people still have problems with the confusion of direction and/or non-provision of risk factors in walking. This study aimed to propose a scheme which constructs data for mobility-impaired or traffic-impaired people based on various geospatial information. The factors and components related to walking for the visually impaired are selected by geospatial data and a walking route guidance network that can be applied to a commercial software. As a result, it was confirmed that road direction guidance would be possible if additional contents, such as braille blocks (dotted/linear), sound signals, bus stops, and bollards are secured. In addition, an initial version of the application software was implemented based on the suggested data model and its usefulness was evaluated to a visually impaired person. To advance the stability of the service in walking for the visually impaired people, various geospatial data obtained by multiple institutes are necessary to be combined, and various sensors and voice technologies are required to be connected and utilized through ICT (Information and Communications Technologies) technology in near future.

A Rheological Study on Creep Behavior of Clays (점토(粘土)의 Creep 거동(擧動)에 관한 유변학적(流變學的) 연구(研究))

  • Lee, Chong Kue;Chung, In Joon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.53-68
    • /
    • 1981
  • Most clays under sustained load exhibit time-dependent deformation because of creep movement of soil particles and many investigators have attempted to relate their findings to the creep behavior of natural ground and to the long-term stability of slopes. Since the creep behavior of clays may assume a variety of forms depending on such factors as soil plasticity, activity and water content, it is difficult and complicated to analyse the creep behavior of clays. Rheological models composed of linear springs in combination with linear or nonlinear dashpots and sliders, are generally used for the mathematical description of the time-dependent behavior of soils. Most rheological models, however, have been proposed to simulate the behavior of secondary compression for saturated clays and few definitive data exist that can evaluate the behavior of non-saturated clays under the action of sustained stress. The clays change gradually from a solid state through plastic state to a liquid state with increasing water content, therefore, the rheological models also change. On the other hand, creep is time-dependent, and also the effect of thixotropy is time-function. Consequently, there may be certain correlations between creep behavior and the effects of thixotropy in compacted clays. In addition, the states of clay depend on water content and hence the height of the specimen under drained conditions. Futhermore, based on present and past studies, because immediate elastic deformation occurs instantly after the pressure increment without time-delayed behavior, the factor representing immediate elastic deformations in the rheological model is necessary. The investigation described in this paper, based on rheological model, is designed to identify the immediate elastic deformations and the effects of thixotropy and height of clay specimens with varing water content and stress level on creep deformations. For these purposes, the uniaxial drain-type creep tests were performed. Test results and data for three compacted clays have shown that a linear top spring is needed to account for immediate elastic deformations in the rheological model, and at lower water content below the visco-plastic limit, the effects of thixotropy and height of clay specimens can be represented by the proposed rheological model not considering the effects. Therefore, the rheological model does not necessitate the other factors representing these effects. On the other hand, at water content higher than the visco-plastic limit, although the state behavior of clays is visco-plastic or viscous flow at the beginning of the test, the state behavior, in the case of the lower height sample, does not represent the same behavior during the process of the test, because of rapid drainage. In these cases, the rheological model does not coincide with the model in the case of the higher specimens.

  • PDF