• 제목/요약/키워드: Linear lens

Search Result 129, Processing Time 0.198 seconds

Optimized Optical Design of LCD Color-matching BLU Using an RGB Light Source (RGB 광원을 사용한 고효율 LCD Color-matching BLU의 광학적 설계)

  • Jeon, Hwa Jun;Gwag, Jin Seok;Kwon, Jin Hyuk
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.3
    • /
    • pp.101-105
    • /
    • 2019
  • An LCD backlight unit (BLU) using RGB light sources is designed and simulated, in order to improve its optical energy efficiency. A color-matching BLU is designed with a lenticular lens array (LLA) with elements that image the linear RGB light sources onto the RGB subpixels of the color filter. Type-A and Type-B simulations are performed, according to the location of the light sources. As a result, the luminance increases to 210% in Type-A and 270% in Type-B respectively. The optimum values for the height and the gap of the LLA for maximum efficiency are found to be $25{\mu}m$ and $3{\mu}m$ respectively.

Evaluation for Geometric Calibration Accuracy of Zoom-lens CCD Camera (줌렌즈 CCD 카메라의 기하학적 검정 정확도 평가)

  • 유환희;정상용;김성삼
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.3
    • /
    • pp.245-254
    • /
    • 2003
  • Zoom lenses CCD(Charge Coupled Device) cameras have many desirable features but appear to be geometrically unstable and diffcult to calibrate. It is well blown that the zooming camera parameters change with zoom lens position. This paper presents a comparative study of two approaches, namely, DLT(Direct Linear Transformation) introduced by Abdel-Aziz and Karara and the model proposed by Tsai, to evaluate the camera parameters of zoom lenses CCD camera and 3D positioning accuracy. As a result, the accuracy for 3D positioning using Tsai and DLT model is similar in both methods when the set of GCPs and the object are arranged in the same space. However, Tsai model is more stable than DLT in the case that the object is apart from the set of GCPs. Also, the further study for the parameters optimization of conventional DLT is needed to improve accuracy for 3D positioning.

A study on the optimal control of Long Stroke Fast Tool Servo Systems (장거리 구동용 FTS 의 최적 제어에 관한 연구)

  • 이상호;이찬홍;김갑순
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.818-821
    • /
    • 2004
  • With a rapid development in the area of micro and ultra precision technology, the micro surface machining of small size parts are explosively increased. Especially, to improve efficiency of various beams in lens and reflector, non-rotational symmetric form and several mm level heights changeable surface can be machined at a time. These geometric complex 3D surface cannot be machined by general short stroke FTS. The long stroke FTS if firmly needed to move directly several mm and have nm level positioning accuracy for the complex surface form. The long stroke FTS used linear motors to drive moving unit long and fine, aero static bearings to decrease friction and moving errors in guide way, optical linear scale with nm level resolution to measure position of FTS. Furthermore, to increase the performance of acceleration of FTS, the light material, such as AL is used for the structure and the high stiffness box type structure is selected. In this paper, the genetic algorithm approach is described to determine a set of design parameters for auto tuning. The authors have attempted to model the design problem with the objective of minimizing the error, such as variable pattern change. This method can give the better alternative than existing other method.

  • PDF

Design of a Beam-coupling System for a Chip-integrated Spectrometer with a Discrete Linear Waveguide

  • Liu, Zhiying;Jiang, Xin;Li, Mingyu
    • Current Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.229-237
    • /
    • 2020
  • In this study, a beam-coupling system is designed to improve the coupling efficiency of achip-integrated spectrometer when the waveguide is arranged in a linear and discrete manner. In the proposed system the beam is shaped to be anti-Gaussian, to deposit adequate energy in the edge waveguides. The beam is discretely coupled to the corresponding waveguide by a microlens array, to improve the coupling efficiency, and is compressed by a toroidal lens to match the linear discrete waveguides. Based on the findings of this study, the coupling efficiency of the spectrometer is shown to increase by a factor of 2.57. Accordingly, this study provides a reference basis for the improvement of the coupling efficiency of other similar spectrometers.

Ultrahigh-Resolution Spectral Domain Optical Coherence Tomography Based on a Linear-Wavenumber Spectrometer

  • Lee, Sang-Won;Kang, Heesung;Park, Joo Hyun;Lee, Tae Geol;Lee, Eun Seong;Lee, Jae Yong
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2015
  • In this study we demonstrate ultrahigh-resolution spectral domain optical coherence tomography (UHR SD-OCT) with a linear-wavenumber (k) spectrometer, to accelerate signal processing and to display two-dimensional (2-D) images in real time. First, we performed a numerical simulation to find the optimal parameters for the linear-k spectrometer to achieve ultrahigh axial resolution, such as the number of grooves in a grating, the material for a dispersive prism, and the rotational angle between the grating and the dispersive prism. We found that a grating with 1200 grooves and an F2 equilateral prism at a rotational angle of $26.07^{\circ}$, in combination with a lens of focal length 85.1 mm, are suitable for UHR SD-OCT with the imaging depth range (limited by spectrometer resolution) set at 2.0 mm. As guided by the simulation results, we constructed the linear-k spectrometer needed to implement a UHR SD-OCT. The actual imaging depth range was measured to be approximately 2.1 mm, and axial resolution of $3.8{\mu}m$ in air was achieved, corresponding to $2.8{\mu}m$ in tissue (n = 1.35). The sensitivity was -91 dB with -10 dB roll-off at 1.5 mm depth. We demonstrated a 128.2 fps acquisition rate for OCT images with 800 lines/frame, by taking advantage of NVIDIA's compute unified device architecture (CUDA) technology, which allowed for real-time signal processing compatible with the speed of the spectrometer's data acquisition.

One dimensional inhomogeneous aperture modulation effects on the MTF of optical system II (일차원적 비균일 개구변조시 광학계의 최적상면 MTF에 미치는 영향)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.277-281
    • /
    • 1998
  • One dimensional inhomogeneous aperture modulation effects on the MTF of optical system was investigated. The lens under test was a doublet made in Korea. It has 10 mm effective diameter, 87.8 mm effective focal length. The ray-fans and spot diagrams were calculated and presented on the picture for on-axis and off-axis (field of view, $1^{\circ}$ and $2^{\circ}$). Aperture modulation was carried out by positioning a aperture modulator close contacter with the lens under test. We bought two modulators from Edmud Company in U.S.A. One was linear type and the other was stepped type. The MTFs were measured on the best of focus for each modulated aperture where the MTF has the highest value for 60 line/mm and were compared with one another. For on-axis, the MTFs of some modulated apertures had higher values than the MTF of unmodulated aperture in the high frequency region. In the case of off-axis, at the field of view $1^{\circ}$, the MTF values of some modulated aperture are improved prominently and some other one are disimproved. At the field of view $2^{\circ}$ most of the MTFs of modulated apertures had lower values than the MTF of unmodulated aperture except the MTFs of linear and inverse linear type aperture in the high frequency area. But the values of MTFs in high frequency region were too low for actual use.

  • PDF

Development of Multi-Purpose Variable Polarization Imaging System for Clinical Diagnosis (임상 진단용 다목적 가변 편광 영상장치 개발)

  • Bae, Young-Woo;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.265-270
    • /
    • 2007
  • Polarization imaging systems have been widely used to selectively characterize skin lesions. Nevertheless, current systems are used in single-mode due to the limitations of a fixed polarization mode and a single-working distance of light source, in which uniform light distribution is achieved on target area. To address such limitations, we developed a variable polarization imaging system based on multi-working distance of light source for various clinical diagnoses. In this study, we characterize the imaging system and present experiment results demonstrating its clinical usefulness. The imaging system consists of a CCD color camera, linear polarization filters, and a single-layered LED ring light source which provides uniform light distribution at multi-working distances. The first polarizer was placed on the light source and the second polarizer placed on objective lens provides continuous linear polarization angle from $0^{\circ}\;to\;90^{\circ}$. The clinical efficacy of the imaging system was investigated by acquiring and analyzing clinical images of skin wrinkle and dental plaque. With the experiments, we verified the potential usefulness of the imaging system for other clinical applications.

Two Dimensional Electronic Spectroscopy

  • Fleming, Graham R.;Yang, Min-O;Agarwal, Ritesh;Prall, Bradley S.;Kaufman, Laura J.;Neuwahl, Fred
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.8
    • /
    • pp.1081-1090
    • /
    • 2003
  • Two different electronically resonant two-dimensional spectroscopies are described. The first, two-color photon echo peak shift spectroscopy, is sensitive to correlations in transition frequency between the initial and probed (final) states. It provides new insight into the mechanism of ultrafast solvation and should prove useful for characterizing dynamics in inhomogeneous systems in general. The second technique, fifth order threepulse scattering, contains two coherence periods whose durations are controlled. The entire two-dimensional surface was recorded for a dye molecule in dilute solution and a photosynthetic light-harvesting complex. The data provide insight into the short-time dynamics of solvation and exciton relaxation, respectively.

다이아몬드 미세형상가공에서 자려진동의 발생경향과 안전성 평가

  • 이언주;임한석;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.71-74
    • /
    • 1995
  • Diamond shaping is one of the machining strategies to make the optical micro-groove molds,and it is especially useful when rhe component is an assembly of the linear micro-groove array. A mirror-like surface and arbitrary crose-sectional curve can be easily made by diamond. Howerver, the cutting speed of shaping is relatively lower than that of the other cutting methods, and there exist an unstable cutting conditions that generate the chatter. This study is focused on the modeling of the simplified self-induced chatter of the diamond shapping. Form the chatter model and experiments, it is found that the unstable cutting conditions exist wwhen the depth of cut is low and cutting speed is high.

  • PDF

Evaluation for 3-D Reconstruction Accuracy Using Zoom-lens CCD Camera (줌 렌즈 CCD 카메라를 이용한 3차원 복원 정확도 평가)

  • 김성삼;정상용;박홍기;유환희
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.369-376
    • /
    • 2003
  • 최근 고해상력을 가진 줌 렌즈 CCD(Charge Coupled Device) 카메라가 출시되면서 디지털 영상을 쉽게 취득할 수 있게 되어 일상적인 활용에서부터 컴퓨터 시각(computer vision)이나 사진측량과 같은 전문적인 분야에 이르기까지 다양하게 응용할 수 있는 계기가 마련되고 있다. 현재 상용되고 있는 일반 줌 렌즈 CCD 카메라는 영상을 취득하는 데 많은 장점을 갖고 있으나 실제 영상 취득과정에서 다양한 줌의 이동으로 인하여 표정요소계산 및 카메라 렌즈 오차검정에 상당한 어려움이 발생하여 이에 대한 연구가 진행되어오고 있다. 본 연구에서는 기존에 비측량용 카메라에서 취득된 영상을 해석하는 기법으로 사진측량 분야에서 사용되어온 DLT(Direct Linear Transformation) 모델식과 컴퓨터 시각(computer vision)분야에서 카메라 검정 및 3차원 복원에 사용되고 있는 Tsai 모델식을 도입ㆍ적용하여 표정요소계산 및 3차원 복원정확도를 비교 분석하였다. 그 결과 Tsai 모델식에 의한 결과가 DLT 모델식에 의한 결과보다 정확도 및 안정성면에서 향상된 결과를 보여주고 있어서 Tsai 모델식에 대한 사용이 기대된다.

  • PDF