• Title/Summary/Keyword: Linear array transducer

Search Result 42, Processing Time 0.026 seconds

Design of High Efficiency Power Amplifier for Parametric Array Transducer using Variable Output Voltage AC/DC Converter (가변출력전압 AC/DC 컨버터를 이용한 파라메트릭 어레이 트랜스듀서용 고효율 전력증폭기의 설계)

  • Shim, Jae-Hyeok;Lee, Chang-Yeol;Kim, Seul-Gi;Kim, In-Dong;Moon, Won-Kyu;Lee, Jong-Hyeon;Kim, Won-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.364-375
    • /
    • 2014
  • Parametric array transducers are used for long-range and highly directional communication in an underwater environments. The power amplifiers for parametric array transducers should have sufficient linear output characteristic and high efficiency to avoid communication errors, system heating, and fuel problems. But the conventional power amplifier with fixed source voltage is very low efficient due to large power loss by the big difference between the fixed source voltage and the amplifier output voltage. Thus to solve the problems this paper proposes the high efficiency power amplifier for parametric array transducers. The proposed power amplifier ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier and furthermore gets high efficiency by applying the envelope tracking technique that variable source voltage tracks the envelope of the amplified signal. Also the paper suggests the detailed circuit topology and design guideline of class B push-pull type amplifier and variable output voltage AC/DC converter. Its characteristics are verified by the detailed simulation and experimental results.

Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

Design of Ultrasound Dynamic Focusing Systems (초음파 다이나믹 집속 시스템의 설계)

  • 김진하;김청월
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.4
    • /
    • pp.65-71
    • /
    • 1984
  • The design formular of optical focusing systems cannot be applied to ultrasonic B scanners, which use broadband pulses instead of continuous wave. In this paper, a calculation method is studied for analyzing the propagation of ultrasonic broadband pulse excited by ultrasonic array transducers. Using the results, seveial design parameters such as the number of transducer elements, delay time, and the focal point are determined to obtain high resolution in the ultrasonic dynamic focusing system. A dynamic focusing system with low-noise switching characteristics; which attains lateral resolution of 2-3mm all along the axial direction up to 18 cm with a 3.5 MHz linear array transducer, was implemented.

  • PDF

Determination of Focal Laws for Ultrasonic Phased Array Testing of Dissimilar Metal Welds

  • Jing, Ye;Kim, Hak-Joon;Song, Sung-Jin;Song, Myung-Ho;Kang, Suk-Chull;Kang, Sung-Sik;Kim, Kyung-Cho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.427-435
    • /
    • 2008
  • Inspection of dissimilar metal welds using phased array ultrasound is not easy at all, because crystalline structure of dissimilar metal welds cause deviation and splitting of the ultrasonic beams. Thus, in order to have focusing and/or steering phased array beams in dissimilar metal welds, proper time delays should be determined by ray tracing. In this paper, we proposed an effective approach to solve this difficult problem. Specifically, we modify the Oglivy's model parameters to describe the crystalline structure of real dissimilar metal welds in a fabricated specimen. And then, we calculate the proper time delay and incident angle of linear phased array transducer in the anisotropic and inhomogeneous material for focusing and/or steering phased array ultrasonic beams on the desired position.

An Improvement of the Lateral Resolution of Linear Array Transducer for Medical Ultrasonic Imaging (의료 진단용 선형 배열 변화기의 측 방향 해상도 개선)

  • 백승한
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.136-141
    • /
    • 1991
  • 초음파 영상 진단기에서 영상의 질을 높이기 위해서는 넓은 범우에서 높은 측 방향 해상도가 요구된다. 측 방향 해상도는 변환기에 의해 발생되는 초음파 빔폭에 의해 좌우되는데 기존의 변환기는 초점 부근에서는 빔폭이 매우 좁으나 집속 범위가 제한되는 단점이 있다. 본 논문에서는 넓은 범위에서 균일한 빔폭을 얻을 수 있는 새로운 형태의 변환기를 제안하고 변환기에 의한 음장 분포를 전산기 모의 실험을 통해 구하였으며 그 결과 초점 부근에서는 빔 폭이 기존의 변환기에 비해 다소 넓어지나 집속 범위가 기존의 변화기에 비해 넓어지는 것을 확인할 수 있었다.

  • PDF

Experimental Investigation of Characteristics Change by Kerf-Fill Material between Arrayed Elements of a Piezoelectric Transducer (압전 배열 트랜스듀서의 진동 요소간 kerf 충진 매질에 따른 특성변화의 실험적 고찰)

  • Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.5
    • /
    • pp.215-220
    • /
    • 2008
  • The kerfs between arrayed piezoelectric elements in a medical ultrasonic transducer or a piezoelectric composite transducer are generally filled by polymeric materials. The boundary condition of the elements for lateral mode vibration is changed according to the kerf-filling materials, so that the resonance frequency for longitudinal mode of the transducer is also varied. In this study, to investigate the resonance frequency variation for an arrayed transducer experimentally, the piezoelectric vibration elements of $14mm{\times}0.22mm{\times}0.44mm$ were fabricated and those were linearly arrayed. And, the resonance frequencies were measured for three cases of kerf-filling condition, non-filling and two different kinds of epoxy filling. Conclusively, it is confirmed that the resonant frequency variation shows the similar tendency with the theoretical one for the longitudinal mode.

Development of Differential Diagnosis and Treatment Method of Reproductive Disorders Using Ultrasonography in Cows III. Differential Diagnosis between Developing and Regressing Corpus Luteum (초음파검사에 의한 소의 번식장애 감별진단 및 치료법 개발 III. 발육황체와 퇴행황체의 감별)

  • 손창호;강병규;최한선;임원호;강현구;오기석;신종봉;서국현
    • Journal of Veterinary Clinics
    • /
    • v.16 no.1
    • /
    • pp.118-127
    • /
    • 1999
  • The aim of this study was to establish the method of differential diagnosis between developing and regressing corpus luteum in cows. Plasma progesterone (P$_4$) concentrations were determined by radioimmunoassay in slaughtered, cycling and pregnant cows. Ultrasonography was used to measure the corpus luteum size and histogram values for determining the correlationships between corpus luteum area or histogram values and plasma P$_4$ concentrations. The corpora lutea were monitored in vitro (water-bath scanning) by using ultrasonography with 7.5 MHz linear-array transducer in 196 slaughtered cows. The correlation coefficient between corpus luteum area and plasma P$_4$ concentrations was 0.46 (p<0.01), and between histogram values and plasma P$_4$ concentrations was -0.44 (p<0.01), respectively. The corpora lutea were monitored by ultrasonography with 5.0 MHz linear-array transrectal transducer in 188 cycling and 30 pregnant cows. The corpus luteum areas and plasma P4 concentrations were significantly different between regressing and other corpora lutea (p<0.01), and also histogram values were significantly different between regressing and developing corpola lutea (p<0.01). The correlation coefficients between corpus luteum areas and plasma P$_4$ concentrations were 0.76 (p<0.01), 0.71 (p<0.01), 0.65 (p<0.05) and 0.68 (p<0.05), and between histogram values and plasma P$_4$ concentrations were 0.74 (p<0.05), 0.71 (p<0.01), -0.52 (p<0.05) and 0.65 (p<0.05) in developing, functional, regressing and pregnant corpora lutea, respectively. These results indicate that corpus luteum areas and plasma P$_4$ concentrations were highly correlated in all stages of corpus luteum. The histogram values and plasma P$_4$ concentrations were positive correlated in developing, functional and pregnant corpora lutea, but negative correlated in regressing corpus luteum. Therefore, the measurement of corpus luteum area and histogram value by ultrasonography is reliable method for the assessment of luteal function, specially developing and regressing corpus luteum.

  • PDF

Ultrasound Imaging for Position of the Sciatic Nerve Division in Korean Female (한국 여성에서 좌골 신경 분지 위치에 대한 초음파 영상)

  • Nam, Il Hyun;Yeo, Eui Dong;Yu, Ji Soo;Lee, Jun Ho;Lee, Young Koo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose: We aim to determine sciatic nerve bifurcation location and depth at the level of the popliteal fossa in Korean female. Materials and Methods: Thirty three subjects were enrolled in Korean female. M-turbo ultrasound system (SonoSite, bothell, WA, USA)with 38 mm high frequency linear array transducer, 13-6 MHz probe was used for ultrasound measurements. With subject lying prone, the location of the sciatic nerve in relation to the popliteal crease and skin to nerve distance were assessed via ultrasound. Analyses were performed with SAS version 9.3 using multiple linear regression. Results: Thirty three subjects were enrolled. Distance from the popliteal crease to the sciatic nerve was 4.5-7.5 (mean 5.7 cm), and the depth of the sciatic nerve from the skin was 1.8-3.2 (mean 2.4 cm). Multiple linear regression for the usefulness of the model has a p value of 0.036, shows between weight and depth. Conclusion: We show that variability exists for sciatic nerve bifurcation location in Korean female, The success rate is creased if consider the relations between weight and depth when performs sciatic nerve block in Korean female. In our study, a sciatic nerve block is recommend that performed 7.5 cm proximal to the crease in the popliteal fossa.

  • PDF

Measurement of Acoustic Power Radiating from Each Channel of Linear Array Transducer for Diagnostic Ultrasonic Imaging System (초음파 영상 진단기용 선형 어레이 변환기의 채널별 음향파워 측정)

  • Yun Yong Hyeon;Jho Moon Jae;Kim Yong Tae;Lee Myoung Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.351-352
    • /
    • 2004
  • 본 논문에서는 초음파 영상 진단기용 선형어레이 변환기를 장착할 수 있는 수조 와 128 채널의 스위칭 회로를 제작하여 변환기의 각 채널별 음향파워를 측정하였다. 실험은 128 채널 중 하나의 채널이 불량인 어레이 프로브를 대상으로 수행되었다. 측정 결과, 불량 채널의 음향 파워가 다른 채널에 비해 현저히 작게 나타남을 확인하였다.

  • PDF

Design and Fabrication of Linear Array Transducer for Ultrasonic Medical Imaging System (초음파 의료 진단기용 선형 배열 변환기의 설계 및 제작)

  • 조영환;성굉모
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.6
    • /
    • pp.43-51
    • /
    • 1991
  • 본 논문에서는 초음파 의료 진단기용 선형 배열 변환기의 설계 및 제작을 수행하였다. 설계시에 는 펄스 인가시의 경우 유용한 등가회로인 KLM 모델을 이용한 전산기의 모의실험을 행하였다. 설계된 변환기는 동작 주파수 3.5MHz, 길이 120mm인 변환기이며 폭은 13mm이며 8개의 부소자로 이루어진 64 개의 소자를 갖는 변환기이다. 설계, 제작된 변환기는 효율적인 에너지 전달과 광대역 특성을 갖도록 하 기 위하여 2개의 음향 정합창을 갖도록 하였으며 압전 물질의 형태에 의해 집속되도록 하였다. 제작된 변환기의 성능 비교를 위해 제작된 변환기와 상용의 변환기의 성능을 동일한 조건에서 측정하였다. 측 정결과, 제작된 변환기는 우수한 성능을 갖는 것을 확인하였으며 실제 초음파 영상진단기에 사용할 경 우 좋은 상을 얻을 수 있다.

  • PDF