• Title/Summary/Keyword: Line-To-Line Discharge

Search Result 459, Processing Time 0.029 seconds

Design and fabrication of Ka-band high-power, high-efficiency spatial combiner using TM01 mode Transducer (TM01 모드 변환을 이용한 Ka 대역 고출력 고효율 공간 결합기 설계 및 제작)

  • Kim, Hyo-Chul;Cho, Heung-Rae;Lee, Ju-Heun;Lee, Deok-Jae;An, Se-Hwan;Lee, Man-Hee;Joo, Ji-Han;Kim, Hong-Rak
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.25-32
    • /
    • 2021
  • In this study, it proposes a mode converter that is relatively easy to implement and can shorten the transmission line length of the final combining port and it was fabricated and tested by applying it to an 8-way spatial combiner. The proposed mode converter converts the signal converted from the doorknob-shaped circular disk connected to the ground into the TM01 mode by opening it in the circular waveguide. The 8-way waveguide spatial combiner is designed and implemented so that 8 signals input from the H-plane are combined in a circular waveguide at the center, and the final combining mode is TM01. The test results confirmed excellent performance with an insertion loss of less than 0.4dB and a combining efficiency of 95% or more. In addition, it was confirmed that it is suitable for high output by calculating the breakdown voltage and discharge threshold power of the new mode conversion structure through electric field analysis. The results confirmed through this study are expected to be applicable to high-power, high-efficiency SSPA in various fields in the future.

Study on the Induced Interaction between Groundwater and Surface Water due to the Tunnel Construction (터널 건설에 따른 인근 하천 영향 평가를 위한 연구)

  • 김태희;김영식;하규철;김구영;고동찬;양인제;홍순택
    • The Journal of Engineering Geology
    • /
    • v.14 no.1
    • /
    • pp.81-91
    • /
    • 2004
  • The objective of this study is the evaluation of the tunneling effect on the goundwater-surface water interaction. The designed tunnel line is laid beneath the Hapo-cheon, which runs throughout the study area. And, the pre-evaluation of the tunnel-influence on the Gapo-cheon is urgently needed. However, it is very difficult to find out the similar domestic and/or foreign cases. In this study, the numerical modeling technique was not considered because of the insufficient data. Instead of the numerical modeling, the measurement and analysis of the stream flow rates 5 different points were adopted to evaluate the influence of the tunnel construction on the Gapo-cheon. Based on the analysis of flow monitoring data, it can be concluded that 39% of flow rate in Gapo-cheon is contributed by the groundwater discharge, as baseflow and the construction of tunnel can seriously decrease the flow rate in Gapo-cheon.

Clinical Observation of The Allergic Rhinitis (알레르기성 鼻炎 患者에 對한 臨床的 考察)

  • Kim, Nam-Kwen;Lim, Gyu-Sang;Hwang, Choong-Yeon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.10 no.1
    • /
    • pp.367-382
    • /
    • 1997
  • The author analyzed 46 cases of allergic rhinitis patients, who were treated in the Kwang-ju Oriental Medical Hospital of Wonkwang University from January 1997 to April 1996. I've examined the 46 cases in the view of age and sex distribution, seasonal distribution, distribution of the job, duration of the disease, past history, family history, distribution of complicated signs, the degree of recovery about the total patient, the relationship of the ages and the remedial value, the relationship of the duration of disease and the remedial value. The following results are obtained. 1. The ratio of under teenagers was $32.61\%$(15 cases), teenagers was $30.43\%$(11 cases), 2th decade was $17.39\%$(8 cases), 3th decade was $17.39\%$(8 cases), 4th decade was $4.35\%$(2 cases), 5th decade was $2.17\%$(1 case), over sixty was $2.17\%$(1 case). 2. The ratio of the male was $58.70\%$(27 cases) and femal was $41.30\%$(19 cases). 3. The ratio of spring was $21.74\%$(10 cases), summer was $8.70\%$(4 cases), fall was $43.48\%$(20 cases), winter was $43.48\%$(20 cases) and unknown was $10.87\%$(5 cases). 4. The ratio of the students was $45.65\%$(21 cases), house-wives was $15.22\%$(7 cases), office men was $10.87\%$(5 cases), farmers was $4.35\%$(2 cases), driver was $2.17\%$(1 case) and unemployed was $21.74\%$(10 cases). 5. The ratio of the under six months was $8.70\%$(4 cases), under 1 year was $17.39\%$(8 cases), under 3 years was $32.60\%$(15 cases), over 3 years was $41.31\%$(19 cases). 6. The ratio of atopic dermatitis was $32.61\%$(15 cases), allergic dermatitis was $21,74\%$(10 cases), the asthma was $17.39\%$(8 cases), digestion disorder was $6.52\%$(3 cases) and etc. 7. The ratio of paternal line was $21.74\%$(10 cases), maternal line was $13.04\%$(6 cases), paternal and maternal lines was $4.35\%$(2 cases), brother or sisters was $13.04\%$(6 cases) and non-significant was $47.83\%$(22 cases). 8. The ratio of sneezing was $100\%$(46 cases) , nasal discharge was $100\%$(46 cases), nasal obstruction was $86.96\%$(40 cases), pruritus was $45.65\%$(21 cases), headache was $13.04\%$(6 cases), asthma was $10.87\%$(5 cases), digestion disorder was $6.52\%$(3 cases), light phovia was $6.52\%$(3 cases), tears was $4.35\%$(2 cases), nosebreeding was $2.17\%$(1 case). 9. The total remedial value of the 46 patients was revealed $52.17\%$. 10. The remedial value of under teenagers, teenagers were higher than the total remedial value($52.17\%$). 11. The remedial value of under 6 months, under 1 year were higher than the total remedial value($52.17\%$). These results demonstrated that in the point of remedial view, the patients who were younger and shorter of the duration of disease, would be well recovered.

  • PDF

Continuous Near-field Mixing with Variable Oceanic Conditions (해양수리특성의 변화를 고려한 연속적 근역혼합거동)

  • Kang See Whan;Kim Young Do;Lee Ho Jin;Kim Sang Ik;Han Sung Dae
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.4
    • /
    • pp.12-20
    • /
    • 2001
  • The temporal variability in near-field mixing characteristics of discharging plumes in oceanic environment was investigated using the time series data of the buoyant jet parameters. Based on the currents and density profiles observed in Masan outfall site and effluent discharge flowrates for 63days of summer season, the temporal variabilities and those occurrence frequency were obtained by line plume equations. The results show that wide range of variability in Masan outfall's mixing characteristics was found due to the temporal changes of effluent flowrates and ambient oceanic conditions. The near-field dilution was in the range of 30~71 with the averaged dilution of 34, which was a good agreement with field measurements of salinity deficit. The length of mixing zone was in the range of 5.4~36.2 m with the average of 9.5 m, and the plume rise height was in the range of 8.1~10.2 m with the average of 8.9 m. However, only the 30~44% of the whole results are higher than the averages, which indicates the necessity of this frequency analysis with the continuously measured data for designing and managing the ocean outfall system.

  • PDF

Study on the Improvement of Distribution Pattern in the Triple Nozzle System (동력분무기용(動力噴霧機用) 삼분두(三噴頭)의 살포도(撒布度) 개선(改善)에 관(關)한 연구(硏究))

  • Hong, Soung Wha;Lee, Sang Woo
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.2
    • /
    • pp.284-294
    • /
    • 1984
  • Effects of orifice diameter, operating angle and swirl chamber distance were examined to study a reasonable distribution pattern on the maximum available travel distance in the triple nozzle system. The results of the study were as follows; 1. Discharge rate was increased with increase of orifice diameter, and a quadratic line for the 1st nozzle and linear lines for the 2nd or the 3rd nozzle. 2. The operating angle of $15^{\circ}$ had showed the maximum available travel distance, and 17m in orifice diameter of 3.0mm and operating pressure of $24.5{\times}10^5pa$ ($25Kg/cm^2$). 3. Nozzle setting methods (reference Table 6.) for improvement of uniformity of deposit distribution were varied depending on the size of orifice diameter of the 1st nozzle, nevertheless coefficients of uniformity were improved about 6 percents. 4. Adjustment of the swirl chamber distance of the 2nd nozzle could improve the minimum area of about 6m from the triple nozzle.

  • PDF

Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation (바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석)

  • Lee, Jongmin;Kim, Dongwon;Park, Kyoungil;Lee, Gyuhwa
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.642-650
    • /
    • 2020
  • In general, the circulation path of the fluidized particles in a CFB (Circulating Fluidized Bed) boiler is such that the particles entrained from a combustor are collected by a cyclone and recirculated to the combustor via a sealpot which is one of non-mechanical valves. However, when a fluidized bed heat exchanger (FBHE) is installed to additionally absorb heat from the fluidized particles, some particles in the sealpot pass through the FBHE and then flow into the combustor. At this time, in the FBHE operated in the bubbling fluidization regime, if the heat flow is not evenly distributed by poor mixing of the hot particles (800~950 ℃) flowing in from the sealpot, the heat exchanger tubes would be locally heated and then damaged, and the agglomeration of particles could also occur by formation of hot spot. This may affect the stable operation of the circulating fluidized bed. In this study, the unevenness of heat flow arising from structural problems of the FBHE of the domestic D-CFB boiler was found through the operating data analysis and the CPFD (Computational Particle Fluid Dynamics) simulation using Barracuda VR. Actually, the temperature of the heat exchanger tubes in the FBHE showed the closest correlation with the change in particle temperature of the sealpot. It was also found that the non-uniformity of the heat flow was caused by channeling of hot particles flowing in from the sealpot. However, it was difficult to eliminate the non-uniformity even though the fluidizing velocity of the FBHE was increased enough to fluidize hot particles vigorously. When the premixing zone for hot particles flowing in from the sealpot is installed and when the structure is changed through the symmetrization of the FBHE discharge line for particles reflowing into the combustor, the particle mixing and the uniformity of heat flow were found to be increased considerably. Therefore, it could be suggested that the structural modification of the FBHE, related to premixing and symmetric flow of hot particles, is an alternative to reduce the non-uniformity of the heat flow and to minimize the poor particle mixing.

Colombia Border Area Refugees: Centered on Venezuela, Panama, and Ecuador Border Areas (콜롬비아 국경지역 난민증가 원인: 베네수엘라, 파나마 그리고 에콰도르 접경지역 강제실향민을 중심으로)

  • Cha, Kyung-Mi
    • Journal of International Area Studies (JIAS)
    • /
    • v.15 no.1
    • /
    • pp.109-134
    • /
    • 2011
  • Drug-related crime has increased in spite of visible results of Uribe government's hard-line policies on drug eradication and illegally armed organizations which were pursued under U.S. support, without the accompaniment of quantity change in drug cultivation and trade. Military disputes of left-right illegally armed communities surrounding illegal crop cultivation rights were rather intensified, and the number of refugees was increased through enforced displaced people. The 2005 refugee registration committee RUPD reports that 3,316,862 people, 7.3% of total population, were refugees. In particular, the number of refugees presented a large increase rate of 624% when compared to the past year due to enforced displaced people. Main discharge areas of enforced displaced people are connected with drug crime and activities of illegally armed organizations, and are places of increased armed disputes in the process of occupied territory expansion of illegally armed communities and militia. Undiscriminated attacks were executed on farmers in the process of occupation of illegal crop cultivation sites by illegally armed organization and militia to emit enforced displaced people, who moved to border areas by crossing national borders. Enforced displaced people were restricted to certain areas before the appearance of Uribe administration. However, enforced displaced people not only presented quantitative expansion, but also showed tendency of nationwide expansion after national security policy was pursued. With the closing of the Amazon area, previously the main route of drug trade, activity base of illegally armed organizations was moved to the Pacific region, and Panama border area experienced refugee increase due to the new policy of enforced displaced people. This study aims to understand the actual condition and cause for the increase in refugees in Colombia based on border areas of Venezuela, which is the nation of highest dispersion of Columbian refugees, Panama, which has appeared as a new destination for refugees after the 90s, and Ecuador, which has experienced sudden refugee increase in 2000.

Air Sampling and Isotope Analyses of Water Vapor and CO2 using Multi-Level Profile System (다중연직농도시스템(Multi-Level Profile System)을 이용한 수증기와 이산화탄소 시료채취 및 안정동위원소 조성 분석)

  • Lee, Dong-Ho;Kim, Su-Jin;Cheon, Jung-Hwa;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.277-288
    • /
    • 2010
  • The multi-level $H_2O/CO_2$ profile system has been widely used to quantify the storage and advection effects on energy and mass fluxes measured by eddy covariance systems. In this study, we expanded the utility of the profile system by accommodating air sampling devices for isotope analyses of water vapor and $CO_2$. A pre-evacuated 2L glass flask was connected to the discharge of an Infrared Gas Analyzer (IRGA) of the profile system so that airs with known concentration of $H_2O$ and $CO_2$ can be sampled. To test the performance of this sampling system, we sampled airs from 8 levels (from 0.1 to 40 m) at the KoFlux tower of Gwangneung deciduous forest, Korea. Air samples in the 2L flask were separated into its component gases and pure $H_2O$ and $CO_2$ were extracted by using a vacuum extraction line. This novel technique successfully produced vertical profiles of ${\delta}D$ of $H_2O$ and ${\delta}^{13}C$ of $CO_2$ in a mature forest, and estimated ${\delta}D$ of evapotranspiration (${\delta}D_{ET}$) and ${\delta}^{13}C$ of $CO_2$ from ecosystem respiration (${\delta}^{13}C_{resp}$) by using Keeling plots. While technical improvement is still required in various aspects, our sampling system has two major advantages over other proposed techniques. First, it is cost effective since our system uses the existing structure of the profile system. Second, both $CO_2$ and $H_2O$ can be sampled simultaneously so that net ecosystem exchange of $H_2O$ and $CO_2$ can be partitioned at the same temporal resolution, which will improve our understanding of the coupling between water and carbon cycles in terrestrial ecosystems.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF