• Title/Summary/Keyword: Line source model

Search Result 272, Processing Time 0.028 seconds

Development of SSSC Power Flow Model and its Implementation into Continuation Power Flow Algorithm (전력조류계산을 위한 SSSC모델의 개발과 연속조류계산 알고리듬에의 적용)

  • Kim, Seul-Ki;Song, Hwa-Chang;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1158-1160
    • /
    • 1999
  • This paper proposes a SSSC(Static Synchronous Series Compensator) power flow model to be incorporated into power flow calculation for the steady state analysis of the power system. SSSC provides controllable compensating voltage, which is in quadrature with the line current, over an capacitive and an inductive range, independently of the magnitude of the line current. This SSSC model is obtained from the injection model for series connected VSC(Voltage Source Converter) by adding a constraint that the injected voltage should be in quadrature with the line current. In this paper the static model is implemented into the continuation power-flow (CPF) program. It is shown that SSSC has its intrinsic superiority over TCSC in controllable power flow range.

  • PDF

The Development of New UPFG Steady-State Model using Transmission Line Constant G. B (UPFC가 계통에 미치는 영향을 선로정수 G, B의 함수로 표현한 새로운 UPFC 정태 해석모델 개발)

  • Jeon, D.H.;Kim, T.G.;Chu, J.B.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1167-1169
    • /
    • 1999
  • This paper presents the new unified power flow controller(UPFC) load flow algorithm using UPFC transmission line constant model. The UPFC transmission line constant model represents a function of transmission line constant(G.B) UPFC's effect in power system. It can easily be incorporated in a load flow program. The algorithm is suited for monitoring the power system state as well as determining the magnitude and Phase angle of UPFC serial voltage source.

  • PDF

Implementation of Zero-Ripple Line Current Induction Cooker using Class-D Current-Source Resonant Inverter with Parallel-Load Network Parameters under Large-Signal Excitation

  • Ekkaravarodome, Chainarin;Thounthong, Phatiphat;Jirasereeamornkul, Kamon
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1251-1264
    • /
    • 2018
  • The systematic and effective design method of a Class-D current-source resonant inverter for use in an induction cooker with zero-ripple line current is presented. The design procedure is based on the principle of the Class-D current-source resonant inverter with a simplified load network model that is a parallel equivalent circuit. An induction load characterization is obtained from a large-signal excitation test-bench based on parallel load network, which is the key to an accurate design for the induction cooker system. Accordingly, the proposed scheme provides a systematic, precise, and feasible solution than the existing design method based on series-parallel load network under low-signal excitation. Moreover, a zero-ripple condition of utility-line input current is naturally preserved without any extra circuit or control. Meanwhile, a differential-mode input electromagnetic interference (EMI) filter can be eliminated, high power quality in utility-line can be obtained, and a standard-recovery diode of bridge-rectifier can be employed. The step-by-step design procedure explained with design example. The devices stress and power loss analysis of induction cooker with a parallel load network under large-signal excitation are described. A 2,500-W laboratory prototype was developed for $220-V_{rms}/50-Hz$ utility-line to verify the theoretical analysis. An efficiency of the prototype is 96% at full load.

Sensitivity Analysis of Air Pollutants Dispersion Model in the Road Neighboring Area Due to the Line Source -The Object on ISCST3, CALINE4 Model- (선 오염원에 의한 도로변 지역으로의 대기확산모델의 민감도 분석 - ISCST3, CALINE4 모델을 중심으로 -)

  • Ahn, Won-Shik;Park, Myung-Hee;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.16 no.6
    • /
    • pp.715-723
    • /
    • 2007
  • The air pollutant emission is mainly caused by line sources in urban area. For example, the annually totaled air pollutant emission is known to consist of about 80% of line sources in Daegu. Hence, the appropriate assessment on the air pollutants of line sources is very important for the atmospheric environmental management in urban area. In this study, we made a comparative study to evaluate suitable dispersion model for estimating the air pollution from line sources. Two air pollution dispersion models, ISCST3 and CALINE4 were the subject of this study. The results were as follows; In the assessment of air pollution model, ISCST3 was found to have 4 times higher concentration than CALINE4. In addition, actual data obtained by measurement and estimated values by CALINE4 were generally identical. The air pollution assessment based on ISC3 model produced significantly lower values than actual data. The air pollution levels estimated by ISCST3 were very low in comparison with the observational values.

A Study on Thermal Analysis of Dual Beam Laser Welding of Thin Metal Sheet (박판의 이중 빔 레이저 용접에서 열유동 해석에 관한 연구)

  • 김재웅
    • Journal of Welding and Joining
    • /
    • v.15 no.4
    • /
    • pp.99-108
    • /
    • 1997
  • Analytical model for the temperature distribution and the cooling rate of weld in dual beam laser welding is presented for investigating the possibility of controling the cooling rate. The model is based on the solutions to the problem of heat flow due to the distributed and line heat sources for preheating and welding respectively in plates with finite thickness. The effects of beam power, beam distribution parameter, interbeam distance, and welding speed on the resulting temperature distribution and cooling rate are presented. The cooling rates of dual beam laser weld at the weld centerline under the investigated conditions are reduced to as one third of those of welds which were produced by single beam laser. And it appeared that the cooling rate of dual beam laser weld is strongly dependent on the process parameters of preheating laser beam power and welding speed.

  • PDF

A Study on Characteristics of Spacial Variation for Air Pollution as Line Source Using HIWAY-II Model (HIWAY-II 모형을 이용한 대기오염 확산모델에서 공간적 변동 특성)

  • 이정주;도연지;김신도
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.122-128
    • /
    • 1996
  • Many computer programs have been developed for meteorological and air quality simulation. Many of the model the U.S. EPA recommends are available as. part of UNAMAP. HIWAY-II can be used to estimate the concentrations of nonreactive pollutants from highway traffic. As a result, It was found that distribution of concentration wind speed was 1 m/s to 5 m/s were diminished to about 1/2. In our study, we measured air pollutants(CO), temperature and humidity to evaluate. Meteorological parameter were influenced by not only wind direction but also vertical.

  • PDF

Investigation on Contact Resistance of Amorphous Indium Gallium Zinc Oxide Thin Film Transistors with Various Electrodes by Transmission Line Method

  • Lee, Sang Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.3
    • /
    • pp.139-141
    • /
    • 2015
  • Contact resistance of interface between the channel layers and various S/D electrodes was investigated by transmission line method. Different electrodes such as Ti/Au, a-IZO, and multilayer of a-IGZO/Ag/a-IGZO were compared in terms of contact resistance, using the transmission line model. The a-IGZO TFTs with a-IGZO/Ag/a-IGZO of S/D electrodes showed good performance and low contact resistance due to the homo-junction with channel layer.

Towards the Determinants of On-Line Game Sites (온라인 게임사이트 성공요인에 관한 연구)

  • Son, Dal-Ho;Jang, Kyung-Ho
    • The Journal of Information Systems
    • /
    • v.20 no.4
    • /
    • pp.73-101
    • /
    • 2011
  • This study tried to find the source of the success of on-line game sites and the way how the absorption and the satisfaction would have the relationship with the intention-to-use of on-line game sites. The primary purpose of this study is to establish the empirical model on the determinants of on-line game sites. The research model of this study will have insights which are trigger to the higher dimensions on the model and to the importance of the evaluation criterions of game sites. The suggestions of the study are as follows. First, the precedent factors of research model were tested for the commonality with explorative factor analysis and then tried the confirmative factor analysis. Thus, the determinants in this model will be used for further study without an evaluation. Second, the factors which have a most significant effect on the mediating factor like the absorption are a skill of user and an activity of community. Furthermore, the information quality of game sites was most significant in the satisfaction of user. Third, the most factors which included in the research model were significant to intention-to-use, however, the system quality did negatively significant.

Estimation of Source Contribution by Air Pollutant Type (Point, Area, Line) over Seoul Metropolitan Area (수도권지역에서 오염원별 대기오염농도 기여도 평가)

  • Park, Il-Soo;Lee, Suk-Jo;Kim, Jong-Choon;Kim, Sang-Kyun;Lee, Dong-Won;Yoo, Chul;Lee, Jae-Bum;Song, Hyung-Do;Lee, Jung-Young;Kim, Ji-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.495-505
    • /
    • 2005
  • This study is to estimate source contribution by air pollutantion types (point, area, line) over Seoul metropolitan area. The Air Pollution Model (TAPM) and the highly resolved anthropogenic and biogenic gridded emissions ($1km{\times}1km$) were applied to simulate $SO_2,\;NO_2,\;O_3\;and\;PM_{10}$ concentrations by seasons and contribution was estimated by their source types (point, area, line). The results showed that the simulated concentrations of secondary pollutant agreed well with observed values with an index of agreement (IOA) over 0.4, whereas IOAs over 0.3 were observed for most primary pollutants. The contributions of each source types by seasons were similar. The point source contribution was the highest for $SO_2$ at medium level ranged from $55.1\%\;to\;61.5\%$. But the contribution from area source during for the spring and summer increased as the concentration level increased. The line source contribution was the highest for $NO_2$ at all levels ranged from $68.3\%\;to\;93.1\%$. The results indicate that $SO_2$ emissions should be mainly controlled from point source, as well as area source at higher level concentration. Also, $NO_2\;and\;PM_{10}$ to from line source should be controlled.

The Identification of Vibration Source and Its Transmission Paths In Compressor Using PCF Method (PCF법을 이용한 왕복동압축기의 진동원 및 진동전달경로 규명)

  • Lee, Dae-Sung;Hwang, Won-Gul;Lee, You-Yub;Im, Hyung-Eun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.386.1-386
    • /
    • 2002
  • It is necessary to determine the vibration source and its transmission paths in order to develop a low-noise compressor Through the use of multiple-input/single-output(MISO) model, the transmission paths of vibration within a reciprocating compressor have been investigated. In order to identify the transmission path, we measure the accelerations of the block and transverse vibrations of the line discharge tube. (omitted)

  • PDF