• Title/Summary/Keyword: Line load

검색결과 1,858건 처리시간 0.025초

Research on Line Overload Emergency Control Strategy Based on the Source-Load Synergy Coefficient

  • Ma, Jing;Kang, Wenbo;Thorp, James S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1079-1088
    • /
    • 2018
  • A line overload emergency control strategy based on the source-load synergy coefficient is proposed in this paper. First, the definition of the source-load synergy coefficient is introduced. When line overload is detected, the source-load branch synergy coefficient and source-load distribution synergy coefficient are calculated according to the real-time operation mode of the system. Second, the generator tripping and load shedding control node set is determined according to the source-load branch synergy coefficient. And then, according to the line overload condition, the control quantity of each control node is determined using the Double Fitness Particle Swarm Optimization (DFPSO), with minimum system economic loss as the objective function. Thus load shedding for the overloaded line could be realized. On this basis, in order to guarantee continuous and reliable power supply, on the condition that no new line overload is caused, some of the untripped generators are selected according to the source-load distribution synergy coefficient to increase power output. Thus power supply could be restored to some of the shedded loads, and the economic loss caused by emergency control could be minimized. Simulation tests on the IEEE 10-machine 39-bus system verify the effectiveness and feasibility of the proposed strategy.

기체 전달 관로에 있어서 압력 전파의 주파수 응답에 대한 부하 임피던스의 영향 (The Effect of Load Impedances on the Frequency Response of Pressure Propagation in the Pneumatic Transmission Line)

  • 윤선주;손병진
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.344-353
    • /
    • 1994
  • This study numerically analyzed the dynamic characteristics of the frequency response on the pneumatic transmission line with load impedances. The pressure transfer function is represented by the distributed parameter line model. To validate the mathematical approximations of Bessel function ratios, the results of frequency response in a blocked line were compared with those obtained by the Infinite-product, Brown's and Square-root approximations. Special emphasis was given to the frequency response characteristics on the pneumatic transmission line with load impedances. Computations were carried out for the wide range of parameters in terms of load capacitance ratio and load resistance ratio. The present results indicated that the theoretical model is capable of accurately predicting the frequency response characteristics for any configuration of a fluid transmission line.

  • PDF

측정데이터를 이용한 실시간 정적 부하모델링 (On-line Static Load Modeling using Measurement Data)

  • 박상현;정동현;강상균;이병준;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.282-284
    • /
    • 2006
  • In this paper, Static load models are developed using measurement based approach which is fundamental for on-line load modeling. The measurement data can be acquired from PMU(phasor measurement units). On the assumption that we have on-line measurement data, a scheme which is for Static load model capable to apply SCADA/EMS is developed. The Least Squares criterion is used for minimizing between measured and simulated data. In this manner, On-line Static load modeling algorithm can be developed. In this paper, a scheme that simple Static load model is applied for On-line load modeling is studied.

  • PDF

Stability behavior of the transmission line system under incremental dynamic wind load

  • Sarmasti, Hadi;Abedi, Karim;Chenaghlou, Mohammad Reza
    • Wind and Structures
    • /
    • 제31권6호
    • /
    • pp.509-522
    • /
    • 2020
  • Wind load is the principal cause for a large number of the collapse of transmission lines around the world. The transmission line is traditionally designed for wind load according to a linear equivalent method, in which dynamic effects of wind are not appropriately included. Therefore, in the present study, incremental dynamic analysis is utilized to investigate the stability behavior of a 400 kV transmission line under wind load. In that case, the effects of vibration of cables and aerodynamic damping of cables were considered on the stability behavior of the transmission line. Superposition of the harmonic waves method was used to calculate the wind load. The corresponding wind speed to the beginning of the transmission line collapse was determined by incremental dynamic analysis. Also, the effect of the yawed wind was studied to determine the critical attack angle by the incremental dynamic method. The results show the collapse mechanisms of the transmission line and the maximum supportable wind speed, which is predicted 6m/s less than the design wind speed of the studied transmission line. Based on the numerical modeling results, a retrofitting method has been proposed to prevent failure of the tower members under design wind speed.

평행선 지지식 추력베어링에 관한 연구 (A Study on the Parallel Line Pivoted Pad Thrust Bearing)

  • 이경우;김종수;제양규
    • Tribology and Lubricants
    • /
    • 제15권1호
    • /
    • pp.24-28
    • /
    • 1999
  • This paper describes a new pivoting technique to improve bearing performance in pivoted pad thrust bearings. This new technique adjusts the pivot line in a line pivoted pad thrust bearing to be parallel to the trailing edge of a sector shaped pad. Bearing performance factors such as load carrying capacity, frictional torque and flow rate are numerically investigated for conventional point-pivoted and line-pivoted pads and for the new parallel-line pivoting technique. It is shown that the load carving capacity can be maximized with the new technique.

넓은 출력 범위를 갖는 CMOS line driver에 관한 연구 (A study of SMOS line driver with large output swing)

  • 임태수;최태섭;사공석진
    • 전자공학회논문지S
    • /
    • 제34S권5호
    • /
    • pp.94-103
    • /
    • 1997
  • It is necesary that analog buffer circuit should drive an external load in the VLSI design such as switched capacitor efilter (SCF), D/A converter, A/d converter, telecommunicatin circuit, etc. The conventional CMOS buffer circuit have many probvlems according as CMOS technique. Firstly, Capacity of large load ar enot able to opeate well. The problem can be solve to use class AB stages. But large load are operated a difficult, because an element of existing CMOS has a quadratic functional relation with inptu and outut voltage versus output current. Secondly, whole circuit of dynamic rang edecrease, because a range of inpt and output voltages go down according as increasing of intergration rate drop supply voltage. In this paper suggests that new differential CMOS line driver make out of operating an external of large load. In telecommunication's chip case transmission line could be a load. It is necessary that a load operate line driver. The proposal circuit is planned to hav ea high generation power rnage of voltage with preservin linearity. And circuit of capability is inspected through simulation program (HSPICE).

  • PDF

이송률 자동조정을 위한 2차원 칩로드 해석 (Two-dimensional Chip-load Analysis for Automatic Feedrate Adjustment)

  • 배석형;고기훈;최병규
    • 한국CDE학회논문집
    • /
    • 제5권2호
    • /
    • pp.155-167
    • /
    • 2000
  • To be presented is two-dimensional chip-load analysis for cutting-load smoothing which is needed in unmanned machining and high speed machining of sculptured surfaces. Cutter-engagement angle and effective cutting depth are defined as chip-loads which are the geometrical measures corresponding to cutting-load while machining. The extreme values of chip-loads are geometrically derived in the line-line and line-arc-line blocks of the two-dimensional NC-codes. AFA(automatic feedrate adjustment) strategy for cutting-load smoothing is presented based on the chip-load trajectories.

  • PDF

분산형전원이 도입된 배전계통의 리얼타임 최적전압조정을 위한 부하구간 모델링방법 (A Modeling Method of Load Section on High Voltage Distribution Line Integrated with Dispersed Generation System for Real-Time Optimal Voltage Regulation)

  • 김재언;김태응
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.699-703
    • /
    • 1999
  • It is known that the LDC(Line-Drop Compensator) becomes to lose the function of proper voltage regulation for its load currents due to the real and reactive power generated by DGS(Dispersed Generation System), when DGS is introduced into the power distribution system of which the voltage is controlled by LDC. Therefore, in that case, it is very difficult to regulate the distribution line voltage properly by using LDC. One possible solution for this problem is the real-time voltage regulation method which is to optimally regulate the sending-end voltage in real-time by collecting the real-time load data of each load data of each load section between measuring points and by calculating the optimal seding-end voltage value from them. For this, we must know the real-time load data of each load section. In this paper, a modeling method of representing a load section on high voltage line with DGSs as an equivalent lumped load is proposed for gaining the real-time load data. In addition a method of locating the measuring points is proposed. Then, these proposed methods are evaluated through computer simulations.

  • PDF

증조류 선로 고장시 인접선로 과부하에 의한 거리계전기 동작 및 전압불안정 현상 연구 (A study of impedance relay operation and voltage instability caused by over load of neighborhood line at contingency of heavy load line)

  • 윤기섭;이형한;김창곤;안보순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.359-361
    • /
    • 2005
  • This paper presents the method of countermeasures before voltage collapse by load encroachment(impedance of load ability on R-X locus decrease toward zero point) and describes a study of impedance relay(zone-3) operation and voltage instability caused by over load of neighborhood line at contingency of heavy load line.

  • PDF

콘크리트의 균열개구 변위와 하중방향 변위관계 (Relationship between the CMOD and the Load-Line Deflection of Concrete)

  • 김석기
    • 콘크리트학회지
    • /
    • 제9권1호
    • /
    • pp.183-194
    • /
    • 1997
  • 통상적인 방법에 의해 측정된 콘크리트 보의 변위는 지지점의 국부변위나 변위의 측정 위치에 따른 외부적인 요인이 포함된다. 이러한 오류에 의한 변위의 크기는 실제 변위크기와 거의 같은 정도이기 때문에 이를 사용하여 정확한 파괴 파라메타를 구하기 어렵다. 본 연구에서는 외부적인 요인의 영향을 받지 않는 균열개구 변위와 하중작용 방향 변위의 상관관계를 규명하고, 하중 개구부 변위를 파괴특성을 구하는 인자로 사용하였다. 균열개구 변위와 하중방향 변위는 서로비례함을 알 수 있었으며, 이 비례관계를 이용하여 RILEM에서 제시한 파괴에너지 결정방법에 대한 문제점을 발견하였고 이에 대한 수정방법을 제시하였다.