Temperature measurement of the spray flame using micro scale absorption bands and line strength (마이크로 스케일의 흡수선과 흡수강도를 이용한 분무화염의 온도측정)

  • Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2002
  • It is necessary to develope a high frequency diode laser sensor system based on the absorption spectroscopy for the measurement of temperature of the spray flame. DFB diode laser operating near $2.0{\mu}m$ was used to scan over selected $H_2O$ transitions near $1.9{\mu}m\;and\;2.2{\mu}m$, respectively. The measurement sensitivity at wide range of sweep frequency was evaluated using multi-pass cell containing $CO_2$ gas. This diode laser absorption sensor with high temporal resolution up to 10kHz was applied to measure the gas temperature in the spray flame region of liquid-gas 2-phase counter flow flame. The successful demonstration of time series temperature measurement in the spray flame gives us motivation of trying to establish non-intrusive temperature measurement method in the practical spray flame.

  • PDF

On-line Scheduling Analysis for Job-Shop Type FMS

  • Lee, Jeong Hwan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.24 no.64
    • /
    • pp.63-76
    • /
    • 2001
  • This paper presents a job-shop type flexible manufacturing system(FMS) scheduling problem and examines the effects of scheduling rules on the performance of FMS. Several machine and AGV scheduling rules are tested against the mean flow-time criterion. In this paper, I compare the rules under various experimental conditions by using an FMS simulation model. One of the objectives of this study is to discuss how the simulation-based scheduling problem can be operated. The other is to measure sensitivity of the rules to changes at inter arrival time, queue capacity, breakdown rates for machines and AGV, and AGV speed. Therefore, the results of simulation experiments were considered on FMS design and operating stages. A comprehensive bibliograph? is also presented in the paper.

  • PDF

Assessment of RELAP5MOD2 Cycle 36.04 using LOFT Intermediate Break Experiment L5-1 (LOFT중형 냉각재 상실 사고 모사 실험 자료 L5-1을 이용한 RELAP5/MOD2 Cycle 36.04 코드 평가)

  • Lee, E.J.;Chung, B.D.;Kim, H.J.
    • Nuclear Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.66-80
    • /
    • 1991
  • The LOFT intermediate break experiment L5-1, which simulates 12 inch diameter ECC line break in a typical PWR, has been analyzed using the reactor thermal/hydraulic analysis code RELAP5/MOD2, Cycle 36.04. The base calculation, which modeled the core with single flow channel and two heat structures without using the options of reflood and gap conductance model, has been successfully completed and compared with experimental data. Sensitivity studies were carried out to investigate the effects of nodalization at reactor vessel and core modeling on major thermal hydraulic parameters, especially on peak cladding temperature(PCT). These sensitivity items are : single flow channel and single heat structure (Case A), two flow channel and two heat structures (Case B), reflood option added (Case C) and both reflood and gap conductance options added (Case D). The code, RELAP5/MOD2 Cycle 36.04 with the base modeling, predicted the key parameters of LOFT IBLOCA Test L5-1 better than Cases A,B,C and D. Thus, it is concluded that the single flow channel modeling for core is better than the two flow channel modeling and two heat structure is also better than single heat structure modeling to predict PCT at the central fuel rods. It is, therefore, recommended to use the reflood option and not to use gap conductance option for this L5-1 type IBLOCA.

  • PDF

Effect of the circle tunnel on induced force distribution around underground rectangular gallery using theoretical approach, experimental test and particle flow code simulation

  • Vahab, Sarfarazi;Reza, Bahrami;Shadman Mohammadi, Bolbanabad;Fariborz, Matinpoor
    • Structural Engineering and Mechanics
    • /
    • v.84 no.5
    • /
    • pp.633-649
    • /
    • 2022
  • In this study, the effect of circle tunnel on the force distribution around underground rectangular gallery was investigated using theoretical approach, experimental test and Particle flow code simulation (PFC). Gypsum model with dimension of 1500×1500 mm was built. Tensile strength of material was 1 MPa. Dimension of central gallery was 100 mm×200 mm and diameter of adjacent tunnel in its right side was 20 mm, 40 mm and 60 mm. Horizontal distance between tunnel wall and gallery edge were 25, 50, 75, 100 and 125 mm. using beam theory, the effect of tunnel diameter and distance between tunnel and gallery on the induced force around gallery was analyzed. In the laboratory test, the rate of loading displacement was set to 0.05 millimeter per minute. Also sensitivity analysis has been done. Using PFC2D, interaction between tunnel and gallery was simulated and its results were compared with experimental and theoretical analysis. The results show that the tensile force concentration has maximum value in center of the rectangular space. The tensile force concentration at the right side of the axisymmetric line of gallery has more than its value in the left side of the galleries axisymmetric line. The tensile force concentration was decreased by increasing the distance between tunnel and rectangular space. In whole of the configurations, the angles of micro cracks fluctuated between 75 and 105 degrees, which mean that the variations of tunnel situation have not any influence on the fracture angle.

Involvement of GRP78 in the Resistance of Ovarian Carcinoma Cells to Paclitaxel

  • Zhang, Li-Ying;Li, Pei-Ling;Xu, Aili;Zhang, Xin-Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3517-3522
    • /
    • 2015
  • Background: Glucose regulated protein 78 (GRP78) is a type of molecular chaperone. It is a possible candidate protein that contributes to development of drug resistance. We first examined the involvement of GRP78 in chemotherapy-resistance in human ovarian cancer cell. Materials and Methods: The expression of GRP78 mRNA and protein were examined by RT-PCR and western blotting, respectively, in human ovarian cancer cells line (HO-8910). Sensitivity of HO-8910 to paclitaxel was determined with methyl thiazolyl tetrazolium (MTT). Suppression of GRP78 expression was performed using specific small-interfering RNA (siRNA) in HO-8910 cells, and cell apoptosis was assessed by flow cytometry. Statistical analysis was performed using the SPSS 15.0 statistical package. Results: HO-8910 cells, with high basal levels of GRP78, exhibited low sensitivity to paclitaxel. The mRNA and protein levels of GRP78 were dramatically decreased at 24h, 48h and 72h after transfection and the sensitivity to paclitaxel was increased when the GRP78 gene was disturbed by specific siRNA transfection. Conclusions: The results suggested that high GRP78 expression might be one of the molecular mechanisms causing resistance to paclitaxel, and therefore siRNA of GRP78 may be useful in tumor-specific gene therapy for ovarian cancer.

The Role of Charge and Retention in Effective Wet end Management

  • Rantala, T.;Nokelainen J.;Ojala, T;Dr. Taina Sopenlehto
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.1-10
    • /
    • 2000
  • The development of paper machines, increasing machine speeds with new, mostly low basis weight and/or high ash content paper grades, as well as the fact that several trends regarding process items have increased the sensitivity of papermaking. At the same time, papermakers are looking for flexibility in the production line. We can say that with all PMs the biggest benefits with the lowest capital spending can be achieved by focusing on improved wet end management. In order to manage wet end chemistry on a paper machine, our goal is to control sub-process through which we can influence the operation of the entire wet end with maximum effect. Key measurements and controls are-white water consistency control which is the most effective way to control retention - charge demand measurement and control which takes care of concentration of the anionic material entering to PM -ash measurements and controls which are deeply related to retention and paper quality This paper presents and concentrates to two of these key controls ; retention and charge. The purpose of charge control is to give the process control the tools to react to changes caused by amount of dissolved and colloida material incoming to wet end system. It is called coagulation or fixing control. Retention control is then taking care of retention aid flow to the process by responding any changes seen in white water consistency. It is called flocculation control. Each of these solutions separately , and even more effectively all together, stabilize the wet end operations and so greatly improve the produced paper quality and machine runnability. Practical results will be presented and they are referring to the latest mill cases. We have developed the first wet end measuring system in the late 1980s and control solutions based on this modern measuring technology were completely updated in 1990s. This paper introduces the principle, operation , and results of our unique wet end analyzers (retention and charge ) which are at the level of automation solutions as a part of paper machine quality control Especially our newest member of the platform , on-line charge analyzer has reached and set new standards to the on-line charge monitoring.

The Role of Charge and Retention in Effective Wet End Management

  • Rantala, T.;Nokelainen, J.;Ojala, T.;Sopenlehto, Taina
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.44-53
    • /
    • 2000
  • The development of paper machines, increasing machine speeds with new, mostly low basis weight and/or high ash content paper grades, as well as the fact that several trends regarding process items have increased the sensitivity of papermaking. At the same time, papermakers are looking for flexibility in the production line. We can say that with all PMs, the biggest benefits with the lowest capital spending can be achieved by focusing on improved wet end management. In order to manage wet end chemistry on a paper machine, our goal is to control subprocesses through which we can influence the operation of the entire wet end with maximum effect. Key measurements and controls are - white water consistency control which is the most effective way to control retention. - charge demand measurement and control which takes care of concentration of the anionic material entering to PM. - ash measurements and controls which are deeply related to retention and paper quality. This paper presents and concentrates to two of these key controls: retention and charge. The purpose of charge control is to give the process control the tools to react to changes caused by amount of dissolved and colloidal material incoming to wet end system. It is called coagulation or fixing control. Retention control is then taking care of retention aid flow to the process by responding any changes seen in white water consistency. It is called flocculation control. Each of these solutions separately, and even more effectively all together, stabilize the wet end operations and so greatly improve the produced paper quality and machine runnability. Practical results will be presented and they are referring to the latest mill cases. We have developed the first wet end measuring system in the late 1980s and control solutions based on this modern measuring technology were completely updated in 1990s. This paper introduces the principle, operation, and results of our unique wet end analyzers (retention and charge) which are at the level of automation solutions as a part of paper machine quality control. Especially our newest member of the platform, on-line charge analyzer has reached and set new standards to the on-line charge monitoring.

  • PDF

Control of Ammonium Concentration in Biological Processes Using a Flow Injection Analysis Technique (흐름주입분석기술을 이용한 생물공정에서 암모니아 농도의 제어)

  • 이종일
    • KSBB Journal
    • /
    • v.16 no.5
    • /
    • pp.452-458
    • /
    • 2001
  • Concentrations of ammonia in biological processes were controlled by PID controllers and also neural network based controllers (NN controllers). A flow injection analysis system has been to on-line monitor the concentrations of ammonia in a bioreactor. The effect of the analysis error and the residence time of samples on the control performance were studied. The optimal neural network structure was investigated by using computer simulation and found to be a 3(input layer)-2(hidden layer)-1(output layer). The NN controller is often time consuming, but it has advantage over the PID controller in sensitivity. The 3-2-1 NN controller has been applied to control the ammonia concentrations in a simulated bioprocess and also a real cultivation process of yeast. The good control performance showed that the 3-2-1 NN controller based on the FIA system can be used to control the concentration of substrates in biological processes very well.

  • PDF

Histological Subtype of Ovarian Cancer as a Determinant of Sensitivity to Formamidine Derivatives of Doxorubicin - in Vitro Comparative Studies with SKOV-3 and ES-2 Cancer Cell Lines

  • Denel-Bobrowska, M.;Lukawska, M;Oszczapowicz, I;Marczak, A
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4223-4231
    • /
    • 2016
  • Background: Development of new apoptosis-inducing drugs is a promising trend in anticancer therapy. For this purpose several formamidinoderivatives of doxorubicin were synthesized. The aim of our study was to investigate effects of the five formamidinodoxorubicins in the ES-2 human ovarian clear cell carcinoma line, for comparison with data obtained previously for SKOV-3 human ovarian adenocarcinoma cells, to answer the question of whether and to what extent the histological cell type is a possible determinant of sensitivity to tested anthracyclines. Materials and Methods: In our experimental work the following methods were used: spectrophotometric assays with MTT; fluorimetric assays - double staining with Hoechst 33258 and propidium iodide (PI), measurement of caspase-3, -8, -9 activity, intracellular accumulation of DOX and analogues, estimation of drug uptake, mitochondrial transmembrane potential; flow cytometry - phosphatidylserine (PS) externalization with annexin V-FITC and PI fluorochromes. Results: Effects of the derivatives of doxorubicin were partially linked with the specific type of cancer cell although intracellular accumulation and cellular uptake of DOX and derivatives were similar in both. All of the investigated derivatives were considerably more cytotoxic than DOX. Formamidinodoxorubicins were able to induce caspase-dependent apoptotic cell death in both cell types. Conclusions: All new formamidine derivatives of DOX were able to induce caspase - dependent apoptosis in human ovarian cancer cell lines SKOV-3 and ES-2. Obtained results suggested that formamidine derivatives of DOX may be promising candidates for the prospective chemotherapeutic agents for the two different histological subtypes of ovarian cancer.

Study on the Steam Line Break Accident for Kori Unit-1 (고리 1호기에 대한 증기배관 파열사고 연구)

  • Tae Woon Kim;Jung In Choi;Un Chul Lee;Ki In Han
    • Nuclear Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.186-195
    • /
    • 1982
  • The steam line break accident for Kori Unit 1 is analyzed by a code SYSRAN which calculates nuclear power and heat flux using the point kinetics equation and the lumped-parameter model and calculates system transient using the mass and energy balance equation with the assumption of uniform reactor coolant system pressure. The 1.4 f $t^2$ steam line break accident is analyzed at EOL (End of Life), hot shutdown condition in which case the accident would be most severe. The steam discharge rate is assumed to follow the Moody critical flow model. The results reveal the peak heat flux of 38% of nominal full power value at 60 second after the accident initiates, which is higher than the FSAR result of 26%. Trends for the transient are in good agreement with FSAR results. A sensitivity study shows that this accident is most sensitive to the moderator density coefficient and the lower plenum mixing factor. The DNBR calculation under the assumption of $F_{{\Delta}H}$=3.66, which is used in the FSAR with all the control and the shutdown assemblies inserted except one B bank assembly and of Fz=1.55 shows that minimum DNBR reaches 1.62 at 60 second, indicating that the fuel failure is not anticipated to occur. The point kinetics equation, the lumped-parameter model and the system transient model which uses the mass and energy balance equation are verified to be effective to follow the system transient phenomena of the nuclear power plants.lear power plants.

  • PDF