Comparison of High Frequency Detailed Generator Models for Partial Discharge Localization

  • Hassan Hosseini, S.M.;Hosseini Bafghi, S.M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1752-1758
    • /
    • 2015
  • This paper presents partial discharge localization in stator winding of generators using multi-conductor transmission line (MTL) and RLC ladder network models. The high-voltage (HV) winding of a 6kV/250kW generator has been modeled by MATLAB software. The simulation results of the MTL and the RLC ladder network models have been evaluated with the measurements results in the frequency domain by applying of the Pearson’s correlation coefficients. Two PD generated calibrator signals in kHz and MHz frequency range were injected into different points of generator winding and the signals simulated/measured at the both ends of the winding. For partial discharge localization in stator winding of generators is necessary to calculate the frequency spectrum of the PD current signals and then estimate the poles of the system from the calculated frequency spectrum. Finally, the location of PD can be estimated. This theory applied for the above generator and the simulation/measured results show the good correlation for PD Location for RLC ladder network and MTL models in the frequency range of kHz (10kHz<f<1MHz) and MHz (1MHz<f<5MHz) respectively.

부분방전 신호와 잡음의 분리 (Separation of Partial Discharge Signals and Noise)

  • 이승환;유치형;정찬수;김재철;이상철;정양웅
    • 조명전기설비학회논문지
    • /
    • 제13권1호
    • /
    • pp.21-30
    • /
    • 1999
  • 전력용 변압기의 절연 열화를 탐지하기 위한 연구가 오래 전부터 연구되어 왔으며 절연유에 함유된 연소성 가스분석 기술이 주로 활용되고 있다. 최근들어 고압 대용량화에따른 사고 파급효과가 커지게 되면서 on-line 탐지시스템의 필요성이 대두되면서 부분방전 신호 검출법이 연구되기 시작하였다. 본 연구는 부분방전 신호 검출법 중에서 탐촉자의 탈착이 용이한 초음파 신호 측정법에서 가장 큰 문제점인 잡음신호 분리를 위한 연구이다. 신호원의 개수와 위치를 측정할 수 있으므로 측정된 초음파 신호가 부분방전에 의한 것인지 외부 잡음인지를 구별할 수 있으며 변압기의 절연열화 판단에 한층 신뢰성을 향상시킬 수 있게 되었다.

  • PDF

고압회전기 고정자 권선의 부분방전 측정 (Partial Discharge Measurements of High Voltage Rotating Machine Stator Windings)

  • 김희동;이영준;공태식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1828-1830
    • /
    • 2003
  • Partial discharge(PD) tests are used to evaluate the insulation condition of stator windings in two 4.16kV and three 6.6kV motors. These tests were conducted using a conventional partial discharge detector(PDD) and turbine generator analyzer(TGA). Off-line PD measurements were performed on five high voltage motors. PD magnitudes ranged from 1000 pC to 5400 pC at the normal line-to-ground voltage. Five high voltage motors have been equipped with 80pF epoxy-mica coupler on the motor terminal box. The PD pulse from sensors were measured with the TGA instrument. TGA summarizes each plot with two Quantities such as the peak PD magnitude(Qm) and the total PD activity(NQN). The defect mechanisms of high voltage motor can be associated with PD patterns such as internal, slot and conductor surface discharges. The PDD and TGA test results of No. 4 motor showed that internal discharge was detected in voids of the groundwall insulation.

  • PDF

The Characteristics Depending on the Annealing Conditions in the PDP Vacuum In-line Sealing

  • Kwon, Sang-Jik;Kim, Jee-Hoon;Jang, Chan-Kyu;Park, Sung-Hyun;Whang, Ki-Woong;Lee, Kyung-Wha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.703-706
    • /
    • 2004
  • This paper deals with the various sealing conditions in a vacuum and the discharge characteristics. The MgO thin film is prepared by e-beam evaporation method. Sealing process was performed in a vacuum at panel temperature of 430 $^{\circ}C$. We find the cracks on the MgO film surface, which results in higher discharge voltage and lower luminous efficiency. The vacuum in-line sealing technology does not require additional annealing process but induces the MgO cracks because of the high temperature sealing cycle in a vacuum. Therefore we modify the vacuum in-line sealing cycle which the MgO cracks are not found and the good characteristics of plasma displays are found in higher sealing pressure at sealing temperature of 430 $^{\circ}C$.

  • PDF

왕복동 압축기의 소음 및 진동 기여도 분석 (Coherence Analysis of Noise and Vibration For Reciprocating Compressor)

  • 이대성;황원걸;이유엽;임형은
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.875-880
    • /
    • 2002
  • It is necessary to determine the vibration source and its transmission paths in order to develop a low-noise compressor. Through the use of multiple-input/single-output(MISO) mode1, the transmission paths of vibration within a reciprocating compressor have been investigated. In order to identify the transmission path, we measure the accelerations of the block and transverse vibrations of the line discharge tube. As outputs, vibrations of compressor shell were measured at three positions; cylinder head, one near the suction line, and the top of upper shell. The partial coherence function and transfer function are obtained ken the measured data, and the results are observed in order to determine vibration source and its influence on the shell vibration.

  • PDF

임의 방전을 이용한 전차선 열화특성 (The Degradation Properties on Overhead Contact Line Using Artificial Discharge)

  • 고병훈;박영;권삼영;정호성;박현준;김창희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.209-210
    • /
    • 2007
  • This paper describes the various wavelengths of electrical arc on overhead contact line for improvement of the current collection performance. The tests are performed with the arc measuring device and a welding machine to generate electrical are artificially. The experimental result shows the electrical are on overhead contact line and pantograph could be analyzed by artificial discharge.

  • PDF

대용량 터빈 발전기에 사용되는 온라인 부분방전 관측 시스템에 관한 연구 (The Study on a PD On-line Monitoring System Used for Large Turbine Generators)

  • 오광영;강대용;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권1호
    • /
    • pp.45-50
    • /
    • 1999
  • This paper describes a partial discharge (PD) on-line monitoring system used for large turbine generators. The system consists of a broadband current transducer, a computer-aid PD measurement system. By using a programmable fabricate band pass filter and an adaptive digital filter, the system can suppress the noise and extract PD signal from the intense noise surroundings successfully. Two simulated PD sources, which often exist in the large generators, were simulated and detected. At the end of this paper, some field test results, obtained from a 200MW generating set, were presented and discussed.

  • PDF

고압 회전기의 절연열화 진단을 위한 운전중 부분방전 측정 센서의 특성분석 (Characteristics Analysis of On-Line Partial Discharge Measurement Sensor for Insulation Diagnosis of HV Rotating Machines)

  • 윤대희;황돈하;김용주;이광식;김희동;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1909-1911
    • /
    • 2000
  • Recently many research activities on the diagnosis of stator winding insulation of large rotating machines have been reported. Capacitive couplers are widely used as sensors for on-line partial discharge (PD) measurement of high voltage rotating machines. This paper presents laboratory test to compare Stator Slot Coupler (SSC), Resistance Temperature Detector (RTD), 80 [pF] coupler and 500 [pF] coupler for on-line PD measurement of rotating machines.

  • PDF

Flashover Prediction of Polymeric Insulators Using PD Signal Time-Frequency Analysis and BPA Neural Network Technique

  • Narayanan, V. Jayaprakash;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1375-1384
    • /
    • 2014
  • Flashover of power transmission line insulators is a major threat to the reliable operation of power system. This paper deals with the flashover prediction of polymeric insulators used in power transmission line applications using the novel condition monitoring technique developed by PD signal time-frequency map and neural network technique. Laboratory experiments on polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. Partial discharge signals were acquired using advanced ultra wide band detection system. Salient features from the Time-Frequency map and PRPD pattern at different pollution levels were extracted. The flashover prediction of polymeric insulators was automated using artificial neural network (ANN) with back propagation algorithm (BPA). From the results, it can be speculated that PD signal feature extraction along with back propagation classification is a well suited technique to predict flashover of polymeric insulators.

154kV XLPE 케이블 실선로 부분방전 검출 (Partial Discharge Measurement for 154kV XLPE Cable Line)

  • 김충식;이전선;김종철;박창기;석광현;김원년
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.23-25
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnose cable system in the world. Shin-Yeongdeungpo 345kV XLPE line was successfully diagnosed by PD measurement methode last year. Moreover, aged power cable lines which were installed 15 years ago have been tested from this year. In this paper, the result of PD diagnosis for aged 154kV cable line is reported. The PD pattern from TMJ which was monitored by PD measurement system for several days showed typical void pattern. The joint was replaced and voids between semi-conductor layer and insulating layer in the joint was founded.

  • PDF